Loading...
HomeMy WebLinkAboutC&D Transfer Station OM 2018.5.24Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Important:When completing this form on a computer, use only the Tab key to move yourcursor – not the Return key. Third-Party Inspection Report (O&M) – Rev. 12/4/14 Page 1 of 18 Instructions Use this form to record and report the results of a Third-Party Operation and Maintenance Inspection conducted pursuant to 310 CMR 19.018. Be sure to obtain the most recent version of this form. All applicable sections of the submitted form must be completed to be accepted by MassDEP. Pursuant to 310 CMR 19.018(8)(a), the third-party inspector and facility owner/operator must sign this Third-Party Inspection Report form and submit the completed report to the appropriate MassDEP regional office and one copy of each completed report to the board of health of the municipality in which the facility is located. In the event that this inspection report contains a recommendation for corrective action(s), the owner/operator shall also submit the information required by 310 CMR 19.018(8)(c)2. Forms and instructions are available online: http://www.mass.gov/eea/agencies/massdep/recycle/approvals/solid-waste-applications-and-forms.html#8 Note: This form does not identify all of the requirements applicable to each solid waste management facility; other requirements and/or policies may apply to the operation, maintenance and monitoring for each facility. MassDEP Use Only Rec’d Date: FMF #: RO #: Reviewer: Comments: I. Facility Information Facility Type (check one): Transfer Station/Handling Facility C&D Waste Processor or C&D Waste Transfer Station Municipal Waste Combustor Active Landfill Closed Landfill Other:Specify Facility: Nantucket Transfer Station Facility Name Nantucket City/Town MA State 02554 ZIP Code (508) 228-4283 Telephone Number 457936 Regulated Object Account Number FMF Number Operator: Waste Options Nantucket, LLC Operator Name (Doing Business As/Company Name) (508) 228-4283 Telephone Number nathanwidell@comcast.net Email Address 188 Madaket Road Mailing Address Nantucket City/Town MA State 02554 ZIP Code Permittee: Waste Options Nantucket, LLC / Town of Nantucket Permittee Name (Entity Identified on Facility Permit) 188 Madaket Road Mailing Address Nantucket City/Town MA State 02554 ZIP Code Responsible Official for the Facility: Nathan Widell, General Manager Responsible Official Name (Individual) nathanwidell@comcast.net Responsible Official Email Address Waste Options Nantucket, LLC Responsible Official Company Name (508) 228-4283 Responsible Official Telephone Number Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 2 of 18 II. Third-Party Inspector Geoffrey Souza Third-Party Inspector Name SITEC Environmental, Inc. Company Name SW48-0000052 MassDEP Third-Party Inspector Identification Number 06/1/2019 MassDEP Third-Party Inspector Expiration Date (MM/DD/YYYY) (781) 319-0100 Telephone Number gsouza@sitecenv.com Email Address 769 Plain Street, Unit C Mailing Address Marshfield City/Town MA State 02050 ZIP Code Construction and Demolition Waste (C&D Waste) Processing Facility or C&D Waste Transfer Station Only: Identify the qualified individual that conducted the observation of incoming waste loads and collection of samples of suspect asbestos- containing materials during the inspection [pursuant to 310 CMR 19.018(6)(f)]. If the entire inspection was conducted by the third-party inspector listed above, then check the box and enter only the Asbestos Inspector Certification Number. III. Inspection Details A. FREQUENCY Indicate the scheduled inspection frequency for this facility as required by 310 CMR 19.018(6)(b), or a more frequent schedule set forth in the Facility Permit/Other Approval: Bi-Monthly Quarterly Semi-Annual Annual Biennial Other (include permit/approval type and date of issuance): B. DATE, TIME & PERSONNEL Inspection Date (MM/DD/YYYY):05/24/2018 Inspection Start Time:9:45 AM PM Facility Representatives in Attendance During Inspection: John Beans, Operations Manager C. CONDITIONS Air Temperature:Approximately 60 degrees F.Wind Direction (direction from which the wind is blowing): Weather:Clear Partly Cloudy Cloudy NW N NE Dry Rain Snow W Wind E Wind Speed:Calm Breeze Moderate Strong SW S SE Same as above.Provide Asbestos Certification Number ►AI900597 MA Dept. of Labor Standards Asbestos Inspector Certification Number Asbestos Inspector Name Company Name Telephone Number Email Address Mailing Address City/Town State ZIP Code Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 3 of 18 IV. Pre-Inspection Preparation A. FACILITY-SPECIFIC O&M REQUIREMENTS During each third-party inspection, the third-party inspector shall examine and evaluate the facility’s solid waste activities, equipment, operations, practices, procedures, and records relevant to the type of third-party inspection being conducted in order to determine the facility’s compliance with all applicable requirements as set forth in 310 CMR 19.018(6)(a)1. Therefore, pursuant to 310 CMR 19.018(6)(a)1, prior to conducting a third-party facility operation and maintenance inspection, the third-party inspector shall, without limitation, complete all of the following: Review and become familiar with the regulations set forth at 310 CMR 19.000 –Massachusetts Solid Waste Regulations. Identify, review and become familiar with all solid waste permits, plans, approvals, and orders (or other enforcement documents issued to the facility by the Department), and the solid waste requirements applicable to the operation and maintenance of the facility. Relevant requirements may include, without limitation, specific practices and procedures for the operation, maintenance and monitoring of the facility, waste acceptance/storage limits, and other requirements related to the facility’s solid waste activities. Without limitation, these facility-specific requirements may be contained in the Facility Permit, Authorization to Construct, Authorization to Operate, Operation and Maintenance Plan, Closure/Post-Closure Plans and Approvals, Facility Modification Approvals, Beneficial Use Determinations, Administrative Consent Orders, and other determinations, authorizations or enforcement actions issued by the Department. I,Geoffrey Souza, have identified, reviewed and understand all of the aforementioned requirements that are applicable to this facility and the following are my observations and recommendations related to the facility-specific requirements. ►GS Inspector Initials B. SOLID WASTE PERMITS, PLANS, APPROVALS & ORDERS List all relevant solid waste permits, plans, approvals, orders or other enforcement actions issued to the facility by the Department that contain specific practices, procedures and other requirements still in effect for the operation, maintenance and monitoring or closure/post-closure of the facility. Where applicable, provide the plan or issue date for each item. For enforcement actions, include the document number, effective date, and status of implementation by the facility. Discussion: MassDEP Provisional Approval, Renewal of Authorization To Operate, dated: September 28, 2008 Application for Renewal of Authorization to Operate, dated: July 2014 Operation and Maintenance Plan, Revision 4 (Part of Application for ATO Renewal), dated: July 2014 Waste Ban Compliance Plan, dated: June 2014 Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 4 of 18 V. Performance Standards Examine and evaluate the facility’s solid waste activities, equipment, operations, practices, procedures and records relevant to the type of solid waste facility. Using the tables below, identify all areas evaluated by the inspector during the inspection by checking the box in the first column. Describe all deviations noted during the inspection in the third column. Provide recommendations for corrective action to return to compliance with the applicable performance standard in the fourth column. Facility Type Performance Standards Transfer Station/Handling Facility (Including C&D Facility) Complete Section A. If C&D Handling/ Processing Facility, then also complete Section B. Municipal Waste Combustor Complete Section A. Active Landfill Complete Sections C. and F. If active ash landfill, then also complete Section D. Closed Landfill Complete Sections E. and F. A. TRANSFER STATION, HANDLING FACILITY, OR MUNICIPAL WASTE COMBUSTOR (INCLUDING C&D FACILITY) Evaluated Performance Standard Deviation(s) Comments/Observations and Recommended Corrective Action(s) 19.205(1) Storm Water Controls.None Storm water runoff flows overland to a stormwater retention basin located to the northeast of the transfer station building. 19.205(2) Equipment.None Adequate to conduct efficient operations within the transfer station. Equipment includes (1) excavator w/ thumb, (1) front-end loader, (2) bobcats. Other backup equipment available on-site. 19.205(3) Weighing Facilities.None Vehicles entering and existing the facility are weighed at the existing truck scale located at the front entrance. 19.207(1) General.Discuss in Section VI.Discuss in Section VI. 19.207(2) Supervision of Operation.None The Operations Manager was present within the building overseeing unloading and waste load inspection activities. Laborers and equipment operators were also present assisting in the separation of recyclables. The Operations Manager is a certified asbestos inspector. Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 5 of 18 Evaluated Performance Standard Deviation(s) Comments/Observations and Recommended Corrective Action(s) 19.207(3) Access to Facilities.None Access to the transfer facility was good. The travel surface is paved. 19.207(4) Security.None Chain link fencing in place at site perimeter. 19.207(5) Posting of Handling Facility.None A sign has been posted at the transfer station entrance identifying the materials that are not accepted at the facility and materials that are accecpted under specified conditions. 19.207(6) Unloading of Refuse.None The Operations Manager/Waste Load Inspector was present during all waste unloading operations. 19.207(7) Special Wastes.None There was no Special Wastes observed during the inspection. The full time asbestos inspector was present and was observing all incoming waste loads for the presence of ACM. 19.207(8) Banned/Restricted Wastes.None Banned materials are typically sorted out for recycling, when feasible, or are re-loaded onto the hauling vehicle for removal from the site. Zero tolerance items, such as CRTs and batteries, are accepted if presorted and dropped off at the collection area near the scale house at the site entrance. Daily and Comprehensive Load Inspection Forms are maintained in the office trailer. The inspections are performed by the Operations Manager/Waste Load Inspector according to the 2014 Waste Ban Compliance Plan. 19.207(9) Hazardous Waste.None There was no hazardous waste identified during the inspection. 19.207(10) Household Hazardous Waste and Waste Oil Collections. None Household hazardous waste is not collected or managed at this facility. WON does not offer waste oil collection services to Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 6 of 18 Evaluated Performance Standard Deviation(s) Comments/Observations and Recommended Corrective Action(s) customers.None was observed during the inspection. 19.207(11) Bulky Waste.None Bulky items are received at the southerly bay of the transfer station building and are broken up into manageable sizes using the excavator. Bulky waste is transferred for disposal. 19.207(12) Liquid Wastes.None Liquid waste is not accepted.There was no liquid waste observed within incoming loads during the inspection. 19.207(13) Bird Hazards.None The C&D Transfer Station does not accept municipal solid waste and therefore is not an attractive location for birds. There were no birds present during the inspection. Also, there are no airports or other receptors in the immediate vicinity of the transfer station where birds could present a hazard. 19.207(14) Dust Control.None Dust control is provided with the use of a spray hose connected to a hydrant located adjacent to the transfer station building at the bay door entrance. There were no dust control issues identified inside or outside the building during the inspection. 19.207(15) Vector Control.None The C&D Transfer Station does not accept MSW or other putrescible wastes that would be an attraction to vectors. WON has, however, implemented measures to prevent rodent activities with bait boxes observed at the perimeter of the building. 19.207(16) Control of Wind-blown Litter.None All operations are conducted within the building. Chain link fencing is installed along the property line adjacent to the transfer station building. There was no litter observed outside the Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 7 of 18 Evaluated Performance Standard Deviation(s) Comments/Observations and Recommended Corrective Action(s) building during the inspection. 19.207(17) Staffing.None The facility was adequately staffed for the proper management and operations. This staff included the Operations Manager/Waste Load Inspector, heavy equipment operators and laborers who were present on the tipping floor to assist in material separation and handling activities. 19.207(18) Employee Facilities.None Adequate facilities are available on-site for facility personnel including rest rooms and shelter as needed. 19.207(19) Accident Prevention/Safety.None Facility personnel have been trained in the basic principles of health and safety. Training records are available on-site. Appropriate personal safety equipment was being worn by all site employees during the inspection. This equipment included high visibility green safety vests, gloves and boots. 19.207(20) Fire Protection.None The transfer station is equiped with a fire supression system that is serviced by the municipal water supply. There is a fire hydrant located at the building entrance with hoses available. 19.207(21) Recycling Operations.None Removing recyclable materials from incoming waste loads is limited to kick-sorting on the tipping floor. Metals are removed and stored outside the building in the designated metal stockpile area pending shipment off-island. Clean wood waste is sorted out for reuse at the co-composting facility. White goods are accepted and stored outside at the designated stockpile area. Glass Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 8 of 18 Evaluated Performance Standard Deviation(s) Comments/Observations and Recommended Corrective Action(s) containers and bottles received from the on-site MRF or from Phase 1 Landfill reclamation are a stored within a designated bin and crushed periodically for use on access roads. Brush and pallets are accepted and stockpiled adjacent to the transfer station building pending grinding. Presorted CRTs and batteries are accepted and stored at a dedicated location adjacent to the truck scale at the site entrance. 19.207(22) Records for Operational and Plan Execution. None All incoming waste loads are weighed at the on-site scale prior to proceeding to the transfer station building. Records are maintained by the Facility Manager tracking all incoming and outgoing materials by type and tonnage. Annual reports are submitted to the MassDEP by WON as required. 19.207(23) Screening and/or Fencing.None The transfer facility is situated on a remote area of the site and visual screening is not required. Chain linik fencing is in place at the property boundary in the vicinity of the transfer station building. Ongoing waste transfer operations are conducted within the building. The building is fully enclosed with the exception of the bay doors on the easterly side. 19.207(24) Open Burning.None There is no open burning conducted at this facility nor were there any hot loads reported. A Hot Load Area is designated on- Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 9 of 18 Evaluated Performance Standard Deviation(s) Comments/Observations and Recommended Corrective Action(s) site in the event that a hot load arrives at the facility. 19.207(25) Inspections.Semi-Annual Third Party Inspections will continue to be conducted 19.207(26) End-of-Life Mercury-added Products. None There were no mercury added products observed during unloading activities nor were there any observed stored within the building or metal stockpile area. B. CONSTRUCTION AND DEMOLITION (C&D) WASTE PROCESSING FACILITY OR C&D WASTE TRANSFER STATION Evaluated Performance Standard Deviation(s) Comments/Observations and Recommended Corrective Action(s) 19.206(1) Enclosed Operations.None All waste handling was being conducted inside the building. This includes all vehicle unloading, inspecting, removal of recyclables, consolidation and load-out for disposal or transfer off site. 19.206(2) Storage.None.Some recyclable materials are stored outside in designated areas. Materials being stored include mainly scrap metal and white goods, whole tires and glass containers. Material quantities do not exceed permitted maximum limits. 19.206(3) Contact Water.None All waste material is handled within the transfer station building. No stormwater contact with waste. Suspect Asbestos-Containing Material (ACM) Inspection and Management Protocol. None WON is conducting waste load inspections for suspect ACM in accordance with the Protocol. There have no loads containing suspect ACM reported by the Certified Asbestos Inspector and none was detected during the inspection. Sample collection of suspect Discuss sample results:No suspect ACM observed and no Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 10 of 18 Evaluated Performance Standard Deviation(s) Comments/Observations and Recommended Corrective Action(s) ACM from incoming loads.► Attach analytical reports.samples collected. Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 11 of 18 C. ACTIVE LANDFILL Evaluated Performance Standard Deviation(s)Comments/Observations and Recommended Corrective Action(s) 19.130(1) General.Discuss in Section VI.Discuss in Section VI. 19.130(2) Operator Supervision. 19.130(3) Special Wastes. 19.130(4) Banned/Restricted Wastes. 19.130(5) Hazardous Waste. 19.130(6) Bulky Wastes. 19.130(7) Liquid Wastes. 19.130(8) Solid Waste Handling. 19.130(9) Bird Hazards. 19.130(10) Equipment and Shelter. 19.130(11) Staffing. 19.130(12) Employee Facilities. 19.130(13) Accident Prevention/Safety. 19.130(14) Spreading and Compacting of Solid Waste. 19.130(15) Cover Material. 19.130(16) Vector, Dust and Odor Control. 19.130(17) Litter Control. 19.130(18) Top Slope and Side Slopes. 19.130(19) Storm Water Drainage. 19.130(20) Erosion Control. 19.130(21) Boundary/Elevation Markers. 19.130(22) Access Roads. 19.130(23) Security. 19.130(24) Posting of the Landfill. Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 12 of 18 Evaluated Performance Standard Deviation(s)Comments/Observations and Recommended Corrective Action(s) 19.130(25) Open Burning. 19.130(26) Fire Protection and Control. 19.130(27) Convenience and Recycling Drop-off Areas at Landfills. 19.130(28) Waste Oil Collections at Landfills. 19.130(29) Household Hazardous Waste Collections at Landfills. 19.130(30) Leachate Collection, Treatment and Disposal. 19.130(31) Phase Completion of the Landfill. 19.130(32) Disruption of Landfilled Areas. 19.130(33) Construction of Buildings. 19.130(34) Records for Operational and Plan Execution. 19.130(35) Inspections. 19.130(36) Re-circulation of Leachate. 19.130(37) End-of-Life Mercury-added Products. D. ASH LANDFILL Evaluated Performance Standard Deviation(s)Comments/Observations and Recommended Corrective Action(s) 19.131(1) General.Discuss in Section VI.Discuss in Section VI. 19.131(2) Fugitive Emissions. 19.131(3) Ash Moisture Content. 19.131(4) Spreading/Compacting of Ash. 19.131(5) Vehicle Washdown / Wheelwash / Other Measures. Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 13 of 18 E. CLOSED LANDFILL Evaluated Performance Standard Deviation(s)Comments/Observations and Recommended Corrective Action(s) 19.016 Post-closure Use. 19.142(1) General.Discuss in Section VI.Discuss in Section VI. 19.142(2) Post-closure Period. 19.142(3) Post-closure Period Waiver. 19.142(4) Post-closure Period Extension. 19.142(5) Post-closure Requirements. 19.142(6) Inspection Requirements. 19.142(7) Additional Measures. 19.142(8) Termination of the Post- Closure Period. 19.143(1) Applicability. 19.143(2) Submission of Post-closure Use Plans. 19.143(3) Criteria for Approval of Post- closure Use. 19.143(4) Post-closure Construction. Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 14 of 18 F. ADDITIONAL LANDFILL REQUIREMENTS Evaluated Performance Standard Comments/Observations and Recommended Corrective Action(s) 19.132 Environmental Monitoring Requirements. Is the monitoring of surface water, ground water, landfill gas and any other media as determined by the Department, including without limitation, soil and sediment, being conducted on the schedule established in the permit or as otherwise required by the Department? YES NO Are the analytical results of the environmental monitoring submitted to the Department within 60 days after the date of sample collection or as otherwise specified by the Department? YES NO 19.133 Maintenance of Environmental Control and Monitoring Systems. Are the facility operations conducted in a manner which protects all environmental control systems as approved in the Operation and Maintenance plan and monitoring systems as approved in the Operation and Maintenance plan or permit? YES NO Is regular maintenance of all landfill environmental control systems performed as approved in the Operation and Maintenance plan or permit? YES NO Has the Department been notified of the existence and extent of damaged or destroyed environmental control systems, monitoring devices, or surface water sampling location markers in accordance with 310 CMR 19.133(1)(c) and/or 19.133(1)(e)? N/A (if no damage to report)YES NO Continue to Next Page ► Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 15 of 18 F.ADDITIONAL LANDFILL REQUIREMENTS – Continued Evaluated Performance Standard Comments/Observations and Recommended Corrective Action(s) 19.121(4) Landfill Gas Recovery Operation and Maintenance Requirements. Is condensate generation kept to a minimum and condensate recirculation, if proposed, performed in accordance with the permit? YES NO Are the sampling and analysis of condensate conducted on the schedule established in the permit or as otherwise required by the Department? YES NO Are the analytical results of condensate monitoring reported to the Department as established in the permit or as otherwise required by the Department? YES NO Is an annual report on the operation of the landfill gas recovery facility submitted to the Department as specified in the permit? YES NO Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 16 of 18 VI. Inspection Observations A. FACILITY CONDITION AND OPERATIONS Examine and evaluate the facility condition and operations as observed during the inspection, including the following: Describe any evidence of the following conditions observed at the time of the inspection: •Unpermitted discharges to air, water, land or other natural resources of the Commonwealth; and •Dust, odors, litter, and/or other nuisance conditions. Document and discuss all deviations from any specific requirements for the facility that are not addressed in the previous section (Section V.–Performance Standards), including without limitation, the requirements set forth in the facility’s operation and maintenance plan, orders or other enforcement documents, and other solid waste permits, approvals, and authorizations issued to the facility by MassDEP. List the types and estimated quantities of all waste and materials stored at the facility at the time of the inspection. Provide a narrative that describes the overall status of the general condition, operation and performance of the facility as observed at the time of the inspection. Attach photographs taken during the inspection that depict the general condition and operation of the facility. At a minimum, include photographs, as applicable, of the waste unloading (tipping) area, waste storage areas, recyclable material storage and, for transfer stations, the waste reloading activity. Discussion: Photographs are included of the unloading area within the building and the recyclable materials storage areas. B. RECORD REVIEW Examine and evaluate the facility’s record-keeping. Without limitation, document the status of the facility’s compliance with, and any deviations from, the record-keeping required by 310 MCR 19.000; the facility’s operation and maintenance plan; orders or other enforcement documents issued to the facility; and other solid waste permits, approvals, determinations and authorizations issued to the facility by the Department, including the following: Discuss the evaluation of the Facility’s “daily log” such as, daily tonnage records. List and discuss any special incidents that have occurred since the previous inspection such as exceedances of the facility’s permitted waste acceptance limits, nature and outcome of complaints reported to the facility operator (including the identity of the complainant, if known), fires, emergencies, or other disruptions to the routine operation of the facility. Discussion: Excellent records are maintained on incoming and outgoing waste materials and recyclables and for waste ban load inspections. These records are maintained on site and were reviewed during the inspection. There were no exceedances to the approved daily tonnage limit during the past six (6) month period. Massachusetts Department of Environmental Protection Bureau of Waste Prevention / Solid Waste Management Third-Party Inspection Report – 310 CMR 19.018(8) Operation & Maintenance Third-Party Inspection Report (O&M)Page 17 of 18 VII. Summary and Recommendations Pursuant to 310 CMR 19.018(6)(a)4., where a third-party inspector observes that the operation or maintenance of the facility deviates from the aforementioned applicable requirements, he or she shall document all such deviations and recommend corrective actions for the facility to take to return to compliance. A. INSPECTION RESULTS Based on the examinations and evaluations conducted in Sections V. and VI., please summarize the inspection results by checking one of the following determinations: No deviations from the applicable performance standards or additional requirements listed at 310 CMR 19.018(6) were identified during this inspection. If no deviations were identified during the inspection, check this box and proceed to Section VII.B. Deviations from the applicable performance standards or additional requirements listed at 310 CMR 19.018(6) were identified during this inspection and are discussed further in this report. If deviations were identified during the inspection, check this box and ensure that each deviation and the recommended corrective actions are discussed in the applicable section(s) below. B. STATUS OF PREVIOUS RECOMMENDATIONS FOR CORRECTIVE ACTION If a previous inspection report identified deviations with recommendations for corrective action, please describe the action(s) taken since the last inspection to return the facility to compliance with the applicable requirements. Discussion: NA C. RECOMMENDATIONS FOR CORRECTIVE ACTION Based on the results of this inspection, please list all deviations noted during the inspection and provide recommendations for corrective action to return to compliance with the applicable requirement. Recommendations: None D. ADDITIONAL COMMENTS Comments: None VIII. Additional Information Checklist Attach the following additional information, as applicable, to complete the inspection report.* Attach photographs taken during the inspection that depict the general condition and operation of the facility, as required in Section VI.A. For C&D Waste facilities only, attach the analytical results, as required in Section V.B. *Note: Pursuant to 310 CMR 19.018(8), MassDEP may request additional information. Continue to Certification Statement on Next Page ► A-1 Bay entrances to Nantucket Transfer Station A-2 Posted signage detailing accepted materials at bay entrance PHOTOGRAPHIC DOCUMENTATION Nantucket Transfer Station 188 Madaket Road Nantucket, Massachusetts SITEC PROJ. NO. SE15-1124 SITEC ENVIRONMENTAL May 24, 2018 A-3 Operations on tipping floor A-4 Operations on tipping floor PHOTOGRAPHIC DOCUMENTATION Nantucket Transfer Station 188 Madaket Road Nantucket, Massachusetts SITEC PROJ. NO. SE15-1124 SITEC ENVIRONMENTAL May 24, 2018