Loading...
HomeMy WebLinkAbout15-0824_Brant Point Shellfish ReviewOWNER REVIEWISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MARENOVATIONS & ALTERATIONS TOISSUED FOR BID19 AUGUST 2015PROGRESS SET REVISIONS54321ABCOWNER REVIEWG0.01PROJECT INFORMATIONISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MASheet ListSeriesSheetNumber Sheet NameGENERALGENERAL G0.00 COVERGENERAL G0.01 PROJECT INFORMATIONGENERAL G0.02 NOTES, SYMBOLS, ABBREVIATIONSGENERAL G0.03 KEY PLANSGENERAL G1.00 CODE SUMMARYDEMOLITIONDEMOLITION AD1.01 DEMOLITION FLOOR PLAN - FIRST FLOORDEMOLITION AD1.02 DEMOLITION FLOOR PLAN - MEZZANINEDEMOLITION AD1.03 DEMOLITION FLOOR PLAN - ROOF PLANDEMOLITION AD2.00 DEMOLITION REFLECTED CEILING PLAN - FIRST FLOORDEMOLITION AD2.01 DEMOLITION REFLECTED CEILING PLAN - MEZZANINEDEMOLITION AD3.00 DEMOLITION EXTERIOR ELEVATIONSDEMOLITION AD3.01 DEMOLITION EXTERIOR ELEVATIONSARCHITECTURALARCHITECTURAL A1.01 FIRST FLOOR PLANARCHITECTURAL A1.02 SECOND FLOOR PLANARCHITECTURAL A1.03 ROOF PLANARCHITECTURAL A2.01 FIRST FLOOR REFLECTED CEILING PLANARCHITECTURAL A2.02 SECOND FLOOR REFLECTED CEILING PLANARCHITECTURAL A3.00 EXTERIOR ELEVATIONSARCHITECTURAL A3.01 EXTERIOR ELEVATIONSARCHITECTURAL A4.00 BUILDING SECTIONSARCHITECTURAL A4.01 BUILDING SECTIONSARCHITECTURAL A5.00 WALL SECTIONSARCHITECTURAL A7.00 STAIR PLANS, SECTIONS AND DETAILSARCHITECTURAL A9.00 DOOR SCHEDULESARCHITECTURAL A9.01 DOOR DETAILSARCHITECTURAL A12.00 3D REPRESENTATIONS - EXTERIOR VIEWSARCHITECTURAL A12.01 3D REPRESENTATIONS - INTERIOR VIEWSPLUMBINGPLUMBING PD1.01 FIRST FLOOR PLUMBING DEMOLITION PLANPLUMBING PD1.02 SECOND FLOOR PLUMBING DEMOLITION PLANPLUMBING P1.01 FIRST FLOOR PLUMBING PLANPLUMBING P1.02 SECOND FLOOR PLUMBING PLANPLUMBING P5.00 PLUMBING SCHEDULESMECHANICALMECHANICAL MD1.01 FIRST FLOOR MECHANICAL DEMOLITION PLANMECHANICAL MD1.02 SECOND FLOOR MECHANICAL DEMOLITION PLANMECHANICAL M1.01 FIRST FLOOR MECHANICAL PLANMECHANICAL M1.02 SECOND FLOOR MECHANICAL PLANMECHANICAL M2.01 MECHANICAL DETAILSELECTRICALELECTRICAL ED1.01 FIRST FLOOR ELECTRICAL DEMOLITION PLANELECTRICAL ED1.02 SECOND FLOOR ELECTRICAL DEMOLITION PLANELECTRICAL EL1.01 FIRST FLOOR ELECTRICAL LIGHTING PLANELECTRICAL EL1.02 SECOND FLOOR ELECTRICAL LIGHTING PLANELECTRICAL EP1.01 FIRST FLOOR ELECTRICAL POWER PLANELECTRICAL EP1.02 SECOND FLOOR ELECTRICAL POWER PLANELECTRICAL E5.00 ELECTRICAL SYMBOLS AND SCHEDULESELECTRICAL E5.01 ELECTRICAL SCHEDULESELECTRICAL E8.00 ELECTRICAL DETAILSPROJECT TEAMSTRUCTURALFOLEY BUHL ROBERTS & ASSOCIATES INC.2150 WASHINGTON ST, NEWTON, MA 02462(617) 527-9600MECHANICAL/ELECTRICAL/PLUMBINGCONSULTING ENGINEERING SERVICES510 CHAPMAN STREET, SUITE 201, CANTON, MA 02021 (617) 261-7161ARCHITECTLLB ARCHITECTS/ LERNER LADDS BARTELS161 EXCHANGE STREET, PAWTUCKET, RI 02860(401) 421-7715NORTHBRANDT POINT SHELLFISHPROPAGATION FACILITY2A EASTON STREETNANTUCKET, MA 02554ALTERNATIVESALTERNATE #1:ADDITION TO WEST SIDE OF BUILDING AND ASSOCIATED DEMOLITION OFEXISTING STRUCTURE. DRAWINGS: AD1.01, AD2.00, A1.01, A2.01BASE BID:NO ADDITION OR ASSOCIATED DEMOLITION.ALTERNATE #2:SIX NEW DORMERS & SIX NEW WINDOW ON EXISITNG ROOF STRUCTUREAND ASSOCIATED DEMOLITION TO EXISTING STRUCTURE. DRAWINGS: AD1.03,AD2.01, A1.03, A2.02BASE BID: NO NEW DORMERS OR ASSOCIATED DEMOLITION.CODE NARRATIVE STATEMENTNOTE: ALL ADD ALTERNATES ARE TO BE PRICED SEPARATELY AS LINE ITEMS ANDCLEARLY NOTED AS ALTERNATES AT THE END OF THE BASE BID. PLEASE REFER TOSPECIFICATIONS FOR ADDITIONAL INFORMATION, THE ADD ALTERNATES ARE ASFOLLOWS:ALTERNATE #3:NEW OVERHEAD DOOR (#17) TO REPLACE EXISITING DOOR (#E10). DRAWINGS:A9.00, A9.01BASE BID: EXISTING DOOR (#E10) TO REMAIN. PREP, PRIME AND PAINT.OWNER'S SPECIAL CONDITIONS FOR CONTRACTORS1)      The contractor must notify the Town Project Manager at least 24 and not morethan 36 hours prior to any work that may obstruct the egress or ingress path of thefacility;2) All existing FF&E is to be removed and stored by owner or salvaged for reinstallationby owner. Owner and contractor to have a coordination meeting prior to start ofdemolition to formulate a list of salvaged versus disposed items.NEW WORK PROPOSED HEREWITHIN LOCATED AT THE BRANDT POINT SHELLFISHFACILITY IS DESIGNED IN COMPLIANCE WITH THE 2009 INTERNATIONAL EXISTINGBUILDING CODE WITH MASSACHUSSETS AMMENDMENTS FOR ALTERATIONS - LEVEL 3WHICH IS DEFINED UNDER IEBC 2009, SECTION 404 AS "INCLUDING THERECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR ORWINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THEINSTALLATION OF ANY ADDITIONAL EQUIPMENT."THE SCOPE OF THIS WORK IS LIMITED TO THE PORTIONS OF THE EXISTING BUILDINGSDESIGNATED IN THESE DOCUMENTS. OTHER EXISTING SPACES AND STRUCTURES ONTHE SITE THAT ARE NOT AFFECTED BY THIS PROJECT ARE NOT COVERED BY THISNARRATIVE.THE SCOPE OF THE PROPOSED WORK IS NOT INTENDED TO MODIFY THE EXISTINGOCCUPANCY CLASSIFICATION, EXISTING OCCUPANCY USE GROUP OR EXISTINGBUILDING CONSTRUCTION CLASSIFICATION. THE INTENT OF THE PROPOSED WORKDOES NOT REDUCE THE REQUIRED EGRESS WIDTH OR CAPACITY FOR ANY PORTION OFTHE WORK, NOR DOES IT REDUCE THE QUANTITY OF EXISTING EXITS.IN GENERAL ALL ALTERATIONS TO A BUILDING OR PORTION THEREOF MUST COMPLYWITH THE REQUIREMENTS OF THE IEBC 2009. THE ALTERATIONS MUST BE SUCH THATTHE ALTERED BUILDING IS NO LESS COMPLYING WITH THE PROVISIONS OF THE CODETHAN THE EXISTING BUILDING WAS PRIOR TO THE ALTERATIONS. NEWLEYCONSTRUCTED ELEMENTS AND SYSTEMS SHALL CONFORM TO THE CODE AND EXISTINGELEMENTS AND CONDITIONS INTENDED TO REMAIN SHALL REMAIN AS-IS.THE ALTERATIONS DETAILED HEREWITHIN HAS BEEN DESIGNED TO BE IN COMPLIANCEWITH THE 2009 INTERNATIONAL EXISTING BUILDING CODE WITH MASSACHUSETTSAMMENDMENTS. AN ADDITION TO A BUILDING OR STRUCTURE SHALL COMPLY WITHTHE INTERNATIONAL CODES AS ADOPTED FOR NEW CONSTRUCTION WITHOUTREQUIRING THE EXISTING BUILDING OR STRUCTURE TO COMPLY WITH ANYREQUIREMENTS OF THOSE CODES.OWNERTOWN OF NANTUCKETBRANDT POINT SHELLFISH PROPAGATION FACILITY2A EASTON STREET, NANTUCKET, MA 025541 Date 1 A.IT SHALL BE THE DUTY OF THE CONTRACTOR TO REQUEST FROM THE ARCHITECT ALL NECESSARYINTERPRETATION OF THE CONTRACT DOCUMENTS.B.DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY AND MAY NOT SHOW ALL DEMOLITION WORKREQUIRED TO COMPLETE THE CONTRACT WORK.C.DIMENSIONS AND ELEVATIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTINGSTRUCTURES ARE THE BEST AVAILABLE DATA OBTAINABLE BUT ARE NOT GUARANTEED BY THE OWNERAND THE OWNER WILL NOT BE RESPONSIBLE FOR THEIR ACCURACY. THE CONTRACTOR SHALL FIELDCHECK AND VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS, OR OTHER CONDITIONS OFLIMITATIONS AT THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK IS PERFORMED BY THECONTRACTOR OR ANY OF HIS SUB-CONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLEDATA, ANY RESULTANT EXTRA COST FOR ADJUSTMENT OF WORK AS REQUIRED TO CONFORM TOEXISTING LIMITATIONS SHALL BE ASSUMED BY THE CONTRACTOR WITHOUT REIMBURSEMENT OFCOMPENSATION BY THE OWNER.D.OMISSION FROM THE DRAWINGS AND SPECIFICATIONS OF ITEMS WHICH OBVIOUSLY ARE NEEDEDTO PROPERLY PERFORM THE WORK, SUCH AS ATTACHMENTS, BOLTS, HANGERS, ETC., SHALL NOTRELIEVE THE CONTRACTOR FROM FURNISHING AND INSTALLING THEM. IT IS INTENDED THAT ALLDIMENSIONS AND FIGURES ON THE DRAWINGS SHALL AGREE. THE CONTRACTOR SHALL CONFIRM THEMBEFORE STARTING THE WORK AND SHALL REPORT IN WRITING ALL DISCREPANCIES TO THE ARCHITECTFOR ADJUSTMENT.E.VERIFY ALL GIVEN DIMENSIONS AND CLEARANCES IN FIELD PRIOR TO WORK. THE CONTRACTORSHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL FIELD CONDITIONS TO DETERMINETHE EXTENT OF DEMOLITION, REMOVAL AND REPAIR. THE CONTRACTOR SHALL IMMEDIATELY NOTIFYTHE ARCHITECT OF ANY ERRORS, OMISSIONS, DISCREPANCIES OR HIDDEN FIELD CONDITIONS WHICHPREVENT THE EXECUTION OF THE WORK AS SHOWN. EXTRA COMPENSATION FOR INADEQUATEEXAMINATION OF EXISTING CONDITIONS SHALL NOT BE CONSIDERED.F.PRIOR TO BEGINNING ANY MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE PROTECTION WORK THECONTRACTOR WILL PROVIDE COMPLETE CAD BASED COORDINATION DRAWINGS THAT CONFIRM ALLDESIRED CEILING HEIGHTS. ANY CONFLICTS THAT WILL AFFECT THE DESIGN INTENT OR DESIGNEDCEILING HEIGHTS WILL BE REPORTED TO THE ARCHITECT PROMPTLY IN ADVANCE OF ENGAGING IN THEWORK.G.REFER TO ALL CONTRACT DOCUMENTS INCLUDING, BUT NOT LIMITED TO DRAWINGS AND SCOPEOF WORK FOR COORDINATION AND ADDITIONAL DEMOLITION INFORMATION. ALL PENETRATIONS INWALLS OR FLOORS RESULTING FROM DEMOLITION OR OVER-DEMOLITION (AS REQUIRED TO PROPERLYINSTALL NEW WORK) OF ANY EXISTING STRUCTURAL, MECHANICAL, ELECTRICAL, FIRE PROTECTION,OR PLUMBING EQUIPMENT ARE TO BE PATCHED WITH NEW MATERIAL TO MATCH EXISTING ANDFINISHED TO MATCH SURROUNDING FINISHED CONSTRUCTION.H.THE GENERAL CONTRACTOR IS REQUIRED TO COORDINATE THE DEMOLITION WORK ASSIGNED TOTHE SUB-TRADES, INCLUDING BUT NOT LIMITED TO ALL UTILITY DISCONNECTS, CUTOFF CAPPING,REMOVAL, DISMANTLING OR DISMOUNTING OF FIXTURES, EQUIPMENT, WIRING, PIPING, ETC. GENERALCONTRACTOR IS RESPONSIBLE FOR ALL REMOVAL AND DISPOSAL.I.THE GENERAL CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR REMOVING ALL EXISTINGMATERIALS WHICH WOULD OTHERWISE INTERFERE WITH THE PROPER INSTALLATION OR FUNCTION OFTHE NEW WORK, WHETHER OR NOT SUCH EXISTING MATERIALS OR CONDITIONS HAVE BEEN INDICATED.THIS INCLUDES ALL ABANDONED FURNISHINGS, EQUIPMENT AND FINISHES.J.ALL MATERIALS AND ITEMS TO BE REMOVED AND NOT RE-USED ON THIS PROJECT SHALL REMAINTHE PROPERTY OF THE OWNER AND SHALL BE TRANSPORTED TO AND STORED IN A PLACE DESIGNATEDBY THE OWNER. IF, HOWEVER, THE OWNER DOES NOT DESIRE TO RETAIN POSSESSION OF ANY ITEMS,THEY SHALL BECOME THE PROPERTY OF THE CONTRACTOR WHO SHALL REMOVE THEM FROM THEPREMISES AND LEGALLY DISPOSE THEREOF.K.UNLESS INDICATED OTHERWISE, THE OWNER WILL REMOVE ALL MOVEABLE EQUIPMENT ANDFURNISHINGS.L.CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AT ALL LOCATIONS AS REQUIRED TOCOMPLETE THE SCOPE OF WORK.M.PROTECT EXISTING TO REMAIN AREAS DURING CONSTRUCTION. PATCH & REPAIR ANY DAMAGECAUSED DURING CONSTRUCTION.N.AFTER THE CONTRACT HAS BEEN AWARDED, THE CONTRACTOR WILL SUBMIT A FULL BAR CHARTTYPE SCHEDULE THAT WILL INDICATE ALL MAJOR AND MINOR MILESTONES FOR THE WORK. THECONTRACTOR WILL ALSO SUBMIT A FULL SUBMITTAL AND SHOP DRAWING SCHEDULE FOR ALLCOMPONENTS TO BE INSTALLED AND PROVIDED PER THE SCOPE OF WORK.O.CERTIFY AS PART OF EACH APPLICATION FOR PAYMENT THAT THE PROJECT RECORD DOCUMENTS"AS-BUILTS" ARE CURRENT AT THE TIME OF THE APPLICATION SUBMITTED. SUCH DRAWINGS AREREQUIRED TO BE CURRENT AS A CONDITION OF APPROVING ANY PAYMENT TO THE CONTRACTOR ORSUB-CONTRACTOR.P.ALL SUBMITTALS AND SHOP DRAWINGS WILL NEED TO BE STAMPED AS HAVING BEEN REVIEWEDAND APPROVED BY THE CONTRACTOR FOR CONFORMANCE WITH THE PROJECT PRIOR TO SUBMITTINGTO THE ARCHITECT. ANY SUBMITTAL WITHOUT THIS STAMP WILL BE PROMPTLY REJECTED ANDRETURNED.Q.CHECKING OF THE SUBMITTALS AND SHOP DRAWINGS BY THE ARCHITECT IS ONLY FOR LIMITEDGENERAL CONFORMANCE WITH THE INFORMATION GIVEN AND DESIGN CONCEPT EXPRESSED IN THECONTRACT DOCUMENTS FOR THE PROJECT. THE CONTRACTOR IS RESPONSIBLE FOR QUANTITIES ANDDIMENSIONS WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOBSITE; CONSTRUCTION MEANS,METHODS, PROCEDURES, TECHNIQUES, SEQUENCES, AND JOBSITE SAFETY; AND COORDINATION OFTHEIR WORK WITH THAT OF THE OTHER TRADES.R.CAREFULLY REVIEW THE SCOPE OF WORK FOR REQUIREMENTS RELATED TO FIELD APPROVED"MOCKUPS". ANY WORK BEGUN WITHOUT THE AUTHORIZATION OF AN APPROVED MOCKUP BY THEOWNER AND THE ARCHITECT IS AT THE CONTRACTOR'S RISK. UNSATISFACTORY WORK IS SUBJECT TOPOSSIBLE REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE.S.IF DISCREPANCIES OCCUR BETWEEN THE DRAWINGS AND SCOPE OF WORK, CONSULT ARCHITECTFOR CLARIFICATION OF DESIRED METHOD. DURING THE BIDDING PHASE IF DISCREPANCIES ARE FOUNDIN THE CONTRACT DOCUMENTS, CARRY THE AMOUNT OF WORK WHICH WOULD COME AT A GREATERCOSTT.REFER TO SCOPE OF WORK FOR REQUIREMENTS PERTAINING TO DEMOLITION ACTIVITIES,INCLUDING NOTIFICATION TO THE OWNER. PROVIDE TEMPORARY PROTECTION REQUIREMENTS, ANDSPECIFIC DEMOLITION PROVISIONS FOR ALL ITEMS INDICATED ON DRAWINGS FOR DEMOLITION THATALLOW FOR SAFE, SANITARY AND LEGAL DISPOSAL OFF OF THE PROPERTY.U.WHERE EXISTING FLOORING HAS BEEN REMOVED, THE GENERAL CONTRACTOR WILL BE REQUIREDTO CLEAN, PREPARE AND PATCH THE EXISTING FLOOR SLAB OR SUBSTRATE TO THE CONDITIONREQUIRED FOR PROPER INSTALLATION OF NEW FLOOR SYSTEM.GENERAL CONSTRUCTION NOTESCOMMON ABBREVIATIONSABVABOVEA/CAIR CONDITIONACC.ACCESS(IBLE)ACTACOUSTICAL CEILING TILEADDLADDITIONALADJ.ADJUSTABLE (OR) ADJACENTA/EARCHITECT/ENGINEERA.F.F.ABOVE FINISH FLOORAHJAUTHORITY HAVING JURISDICTIONALUM.ALUMINUMALT.ALTERNATEANOD.ANODIZEDARCH.ARCHITECT(URAL)A.P.ACCESS PANELAPTAPARTMENTAPPROX.APPROXIMATEASIARCHITECT’S SUPPLEMENTAL INSTRUCTIONAUTO.AUTOMATICAUX.AUXILIARYBASBUILDING AUTOMATION SYSTEMBDBOARDBDRMBEDROOMBITUM.BITUMINOUSBLDGBUILDINGBLKGBLOCKINGBLWBELOWBSMTBASEMENTBOT.BOTTOMBRKBRICKBRZBRONZEBTWNBETWEENCAB.CABINETC.F.M.F.COLD-FORMED METAL FRAMINGC.L.CENTER LINECLG CEILINGCLRCLEAR(ANCE)C.J.CONTROL JOINTCMUCONCRETE MASONRY UNITCOL.COLUMNCOMP.COMPRESS(ED), (ION). (IBLE)CONC.CONCRETECONST.CONSTRUCTIONCONT.CONTINU(E), (OUS)COORD.COORDINATECPTCARPETCPRCOPPERC.T.CERAMIC TILEC.U.H.CABINET UNIT HEATERDBLDOUBLEDEMODEMO(LISH), (LITION)DET.DETAILD.F.DRINKING FOUNTAINDHDOUBLE HUNGDIA.DIAMETERDIAG.DIAGONALDIM.DIMENSIONDNDOWNDRDOORDSDOWNSPOUTDTLDETAILDWGDRAWINGDXDUPLEXEA.EACHEL.ELEVATIONELEC.ELECTRIC(AL)ELEV.ELEVATOREMER.EMERGENCYEMSEMERGENCY MANAGEMENT SYSTEME.J.EXPANSION JOINTEQEQUALEQUIPEQUIPMENTETREXISTING TO REMAINEXGEXISTINGEXT.EXTERIORF.A.FIRE ALARMF.A.R.FLOOR AREA RATIOF.C.U.FAN COIL UNITF.D.FLOOR DRAINFDN FOUNDATIONF.E.FIRE EXTINGUISHERFECFIRE EXTINGUISHER CABINETFF&EFURNITURE, FIXTURE, AND EQUIPMENTFGLFIBERGLASSFIN.FINISHFIXT.FIXTUREFL.FLOORFLUOR.FLUORESCENTF.O.FACE OF _____________F.P.FIRE PROTECTIONFTFEETFTGFOOTINGFURN.FURNITUREGAGAGEGALVGALVANIZEDGBGRAB BARGLGLASSGLAMGLUE LAMINATED BEAMGLZGLAZINGGWBGYPSUM BOARDHCHANDICAPHDFHIGH DENSITY FIBERBOARDHMHOLLOW METALHDWR HARDWAREHOR.HORIZONTALHRHOURHTHEIGHTIN.INCHESINCL.INCLUDE(D),(ING)INFO.INFORMATIONINSUL.INSULATIONINT.INTERIORJ.C.JANITOR’S CLOSETJ-BOXJUNCTON BOXJTJOINTKIT.KITCHENLAB.LABORATORYLAV.LAVATORYLBPOUND(S)L.E.D.LIGHT EMITTING DIODEL.H.LEFT HANDLIB.LIBRARYLKRLOCKERLVLLAMINATED VENEER LUMBERLOC.LOCATIONLVRLOUVERMAS.MASONRYMAT.MATERIALMAX.MAXIMUMMECH.MECHANICALMED.MEDIUMMEMBMEMBRANEMDFMEDIUM DENSITY FIBERBOARDMIN.MINIMUMMISC.MISCELLANEOUSM.O.MASONRY OPENINGM.R.MOISTURE RESISTANTMTLMETALN.A.NOT APPLICABLENAT.NATURALN.C.NOISE CRITERIAN.I.C.NOT IN CONTRACTNKLNICKELNOM.NOMINALN.R.C.NOISE REDUCTION COEFFICIENTN.T.S.NOT TO SCALEO.C.ON CENTERO.H.OPPOSITE HANDOPNGOPENINGOPPOPPOSITEORIG.ORIGINALOVHDOVERHEADOZ.OUNCEPERPPERPENDICULARPLAMPLASTIC LAMINATEPNT PAINTPTDPAINTEDPRPAIRP.T.PRESSURE TREATEDPTNPARTITIONPLYWDPLYWOODQ.T.QUARRY TILER+DREMOVE AND DISPOSER.B.RESILENT BASER.D.ROOF DRAINREF.REFERREFRREFRIGERATORREQ.REQUIRE(D)RES.RESILIENTREV.REVISIONR.H.RIGHT HANDRMROOMR.O.ROUGH OPENINGSCHED.SCHEDULESECT.SECTIONSFSQUARE FEETSHTSHEETSHTHSHEATHINGSIM.SIMILARSPEC.SPEC (-IFIED) (-IFICATION)SRLSUBMITTAL REVIEW LETTERSQ.SQUARES.S.STAINLESS STEELS.S.M.SOLID SURFACE MATERIALSTCSOUND TRANSMISSION COEFFICIENTSTDSTANDARDSTOR.STORAGESTLSTEELSTRUCT.STRUCTURALSUSP.SUSPEND(ED)SYS.SYSTEMT&GTONGUE AND GROOVETEL.TELEPHONETEMPTEMPORARYTHKTHICK(NESS)THRTHRESHOLDT.O.TOP OF ________________TSTATTHERMOSTATTYP.TYPICALTZTERRAZZOU.H.UNIT HEATERU.N.O.UNLESS NOTED OTHERWISEU.O.N.UNLESS NOTED OTHERWISEVERT.VERTICALV.I.F.VERIFY IN FIELDV.R.VAPOR RETARDERW/WITHW.C.WATER CLOSETWDWOODWIN.WINDOWZ.C.C.ZINC COATED COPPER&ANDALUMNIUMCONCRETERIGID INSULATIONCONCRETE BLOCKBRICKEARTHENGINEERED WOOD (MDF, HDF, ETC.)POROUS FILL (GRAVEL, CRUSHED STONE, ETC.)GLASS, HORIZONTAL SURFACEMETAL (STEEL, ETC.)PLASTICPLYWOODRUBBLEGYPSUM/PLASTEREXISTING, UNEXCAVATEDCERAMIC TILE, HORIZONTALSURFACEWOOD (EDGE GRAIN)WOOD (END GRAIN)WOOD (FACE GRAIN)SHINGLECERAMIC TILE, VERTICAL SURFACEGLASS, VERTICAL SURFACEGLASS, SPECIALTYSYMBOLSGENERIC 1GENERIC 2GENERIC 3GENERIC 4GENERIC 5GENERIC 6SYMBOLS0A10.00ROOM NAME100A0100EXTERIOR ELEVATIONINTERIOR ELEVATIONSECTIONELEVATIONSPOT ELEVATIONCOLUMN GRID MARKROOM NAME AND MARKDOOR MARKWALL TYPEWINDOW TYPEA1A1A1A1FURNITURE / SPECIALTYEQUIPMENT MARKALEADERDIMENSIONALIGNBREAK LINEMOCKUP LOCATIONFLOOR FINISHREVISION CLOUDXXDIMALIGNFLOOR FINISH0NEWEXISTINGA.IT SHALL BE THE DUTY OF THE CONTRACTOR TO REQUEST FROM THE ARCHITECT ALLNECESSARY INTERPRETATION OF THE CONTRACT DOCUMENTS.B.DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY AND MAY NOT SHOW ALLDEMOLITION WORK REQUIRED TO COMPLETE THE CONTRACT WORK.C.DIMENSIONS AND ELEVATIONS INDICATED ON THE DRAWINGS IN REFERENCE TOEXISTING STRUCTURES ARE THE BEST AVAILABLE DATA OBTAINABLE BUT ARE NOTGUARANTEED BY THE OWNER AND THE OWNER WILL NOT BE RESPONSIBLE FOR THEIRACCURACY. THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS, GRADES,LINES, LEVELS, OR OTHER CONDITIONS OF LIMITATIONS AT THE SITE TO AVOIDCONSTRUCTION ERRORS. IF ANY WORK IS PERFORMED BY THE CONTRACTOR OR ANY OF HISSUB-CONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLE DATA, ANYRESULTANT EXTRA COST FOR ADJUSTMENT OF WORK AS REQUIRED TO CONFORM TOEXISTING LIMITATIONS SHALL BE ASSUMED BY THE CONTRACTOR WITHOUT REIMBURSEMENTOF COMPENSATION BY THE OWNER.D.OMISSION FROM THE DRAWINGS AND SPECIFICATIONS OF ITEMS WHICH OBVIOUSLY ARENEEDED TO PROPERLY PERFORM THE WORK, SUCH AS ATTACHMENTS, BOLTS, HANGERS, ETC.,SHALL NOT RELIEVE THE CONTRACTOR FROM FURNISHING AND INSTALLING THEM. IT ISINTENDED THAT ALL DIMENSIONS AND FIGURES ON THE DRAWINGS SHALL AGREE. THECONTRACTOR SHALL CONFIRM THEM BEFORE STARTING THE WORK AND SHALL REPORT INWRITING ALL DISCREPANCIES TO THE ARCHITECT FOR ADJUSTMENT.E.VERIFY ALL GIVEN DIMENSIONS AND CLEARANCES IN FIELD PRIOR TO WORK. THECONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL FIELDCONDITIONS TO DETERMINE THE EXTENT OF DEMOLITION, REMOVAL AND REPAIR. THECONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY ERRORS, OMISSIONS,DISCREPANCIES OR HIDDEN FIELD CONDITIONS WHICH PREVENT THE EXECUTION OF THEWORK AS SHOWN. EXTRA COMPENSATION FOR INADEQUATE EXAMINATION OF EXISTINGCONDITIONS SHALL NOT BE CONSIDERED.F.PRIOR TO BEGINNING ANY MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE PROTECTIONWORK THE CONTRACTOR WILL PROVIDE COMPLETE CAD BASED COORDINATION DRAWINGSTHAT CONFIRM ALL DESIRED CEILING HEIGHTS. ANY CONFLICTS THAT WILL AFFECT THEDESIGN INTENT OR DESIGNED CEILING HEIGHTS WILL BE REPORTED TO THE ARCHITECTPROMPTLY IN ADVANCE OF ENGAGING IN THE WORK.G.REFER TO ALL CONTRACT DOCUMENTS INCLUDING, BUT NOT LIMITED TO DRAWINGSAND SCOPE OF WORK FOR COORDINATION AND ADDITIONAL DEMOLITION INFORMATION.ALL PENETRATIONS IN WALLS OR FLOORS RESULTING FROM DEMOLITION OR OVER-DEMOLITION (AS REQUIRED TO PROPERLY INSTALL NEW WORK) OF ANY EXISTINGSTRUCTURAL, MECHANICAL, ELECTRICAL, FIRE PROTECTION, OR PLUMBING EQUIPMENT ARETO BE PATCHED WITH NEW MATERIAL TO MATCH EXISTING AND FINISHED TO MATCHSURROUNDING FINISHED CONSTRUCTION.H.THE GENERAL CONTRACTOR IS REQUIRED TO COORDINATE THE DEMOLITION WORKASSIGNED TO THE SUB-TRADES, INCLUDING BUT NOT LIMITED TO ALL UTILITY DISCONNECTS,CUTOFF CAPPING, REMOVAL, DISMANTLING OR DISMOUNTING OF FIXTURES, EQUIPMENT,WIRING, PIPING, ETC. GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL REMOVAL ANDDISPOSAL.I.THE GENERAL CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR REMOVING ALL EXISTINGMATERIALS WHICH WOULD OTHERWISE INTERFERE WITH THE PROPER INSTALLATION ORFUNCTION OF THE NEW WORK, WHETHER OR NOT SUCH EXISTING MATERIALS ORCONDITIONS HAVE BEEN INDICATED. THIS INCLUDES ALL ABANDONED FURNISHINGS,EQUIPMENT AND FINISHES.J.ALL MATERIALS AND ITEMS TO BE REMOVED AND NOT RE-USED ON THIS PROJECT SHALLREMAIN THE PROPERTY OF THE OWNER AND SHALL BE TRANSPORTED TO AND STORED IN APLACE DESIGNATED BY THE OWNER. IF, HOWEVER, THE OWNER DOES NOT DESIRE TO RETAINPOSSESSION OF ANY ITEMS, THEY SHALL BECOME THE PROPERTY OF THE CONTRACTOR WHOSHALL REMOVE THEM FROM THE PREMISES AND LEGALLY DISPOSE THEREOF.K.UNLESS INDICATED OTHERWISE, THE OWNER WILL REMOVE ALL MOVEABLE EQUIPMENTAND FURNISHINGS.L.CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AT ALL LOCATIONS AS REQUIREDTO COMPLETE THE SCOPE OF WORK.M.PROTECT EXISTING TO REMAIN AREAS DURING CONSTRUCTION. PATCH & REPAIR ANYDAMAGE CAUSED DURING CONSTRUCTION.N.AFTER THE CONTRACT HAS BEEN AWARDED, THE CONTRACTOR WILL SUBMIT A FULL BARCHART TYPE SCHEDULE THAT WILL INDICATE ALL MAJOR AND MINOR MILESTONES FOR THEWORK. THE CONTRACTOR WILL ALSO SUBMIT A FULL SUBMITTAL AND SHOP DRAWINGSCHEDULE FOR ALL COMPONENTS TO BE INSTALLED AND PROVIDED PER THE SCOPE OFWORK.O.CERTIFY AS PART OF EACH APPLICATION FOR PAYMENT THAT THE PROJECT RECORDDOCUMENTS "AS-BUILTS" ARE CURRENT AT THE TIME OF THE APPLICATION SUBMITTED.SUCH DRAWINGS ARE REQUIRED TO BE CURRENT AS A CONDITION OF APPROVING ANYPAYMENT TO THE CONTRACTOR OR SUB-CONTRACTOR.P.ALL SUBMITTALS AND SHOP DRAWINGS WILL NEED TO BE STAMPED AS HAVING BEENREVIEWED AND APPROVED BY THE CONTRACTOR FOR CONFORMANCE WITH THE PROJECTPRIOR TO SUBMITTING TO THE ARCHITECT. ANY SUBMITTAL WITHOUT THIS STAMP WILL BEPROMPTLY REJECTED AND RETURNED.Q.CHECKING OF THE SUBMITTALS AND SHOP DRAWINGS BY THE ARCHITECT IS ONLY FORLIMITED GENERAL CONFORMANCE WITH THE INFORMATION GIVEN AND DESIGN CONCEPTEXPRESSED IN THE CONTRACT DOCUMENTS FOR THE PROJECT. THE CONTRACTOR ISRESPONSIBLE FOR QUANTITIES AND DIMENSIONS WHICH SHALL BE CONFIRMED ANDCORRELATED AT THE JOBSITE; CONSTRUCTION MEANS, METHODS, PROCEDURES,TECHNIQUES, SEQUENCES, AND JOBSITE SAFETY; AND COORDINATION OF THEIR WORK WITHTHAT OF THE OTHER TRADES.R.CAREFULLY REVIEW THE SCOPE OF WORK FOR REQUIREMENTS RELATED TO FIELDAPPROVED "MOCKUPS". ANY WORK BEGUN WITHOUT THE AUTHORIZATION OF AN APPROVEDMOCKUP BY THE OWNER AND THE ARCHITECT IS AT THE CONTRACTOR'S RISK.UNSATISFACTORY WORK IS SUBJECT TO POSSIBLE REMOVAL AND REPLACEMENT AT THECONTRACTOR'S EXPENSE.S.IF DISCREPANCIES OCCUR BETWEEN THE DRAWINGS AND SCOPE OF WORK, CONSULTARCHITECT FOR CLARIFICATION OF DESIRED METHOD. DURING THE BIDDING PHASE IFDISCREPANCIES ARE FOUND IN THE CONTRACT DOCUMENTS, CARRY THE AMOUNT OF WORKWHICH WOULD COME AT A GREATER COSTT.REFER TO SCOPE OF WORK FOR REQUIREMENTS PERTAINING TO DEMOLITION ACTIVITIES,INCLUDING NOTIFICATION TO THE OWNER. PROVIDE TEMPORARY PROTECTIONREQUIREMENTS, AND SPECIFIC DEMOLITION PROVISIONS FOR ALL ITEMS INDICATED ONDRAWINGS FOR DEMOLITION THAT ALLOW FOR SAFE, SANITARY AND LEGAL DISPOSAL OFF OFTHE PROPERTY.U.WHERE EXISTING FLOORING HAS BEEN REMOVED, THE GENERAL CONTRACTOR WILL BEREQUIRED TO CLEAN, PREPARE AND PATCH THE EXISTING FLOOR SLAB OR SUBSTRATE TO THECONDITION REQUIRED FOR PROPER INSTALLATION OF NEW FLOOR SYSTEM.GENERAL DEMOLITION NOTESREVISIONS54321ABCOWNER REVIEWG0.02NOTES, SYMBOLS,ABBREVIATIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MA REVISIONS54321ABCOWNER REVIEWG0.04EQUIPMENT LISTISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MA07/15/153/25/15 - TR/JC NOT REQUIREDAUTO CLAVE - NEED ONE? / WHERENETS, LONG HANDELED, WALL HUNG-LOCATION?DESKS?FILE CABINETS?CLOTHES WASHER AND DRYER - NEEDONE? / WHERENO3/25/15 - TR/JC NOT REQUIREDPEG BOARD WALL MOUNTED? NOGLASSWARE DRYING RACK? NO3/25/15 - TR/JC NOT REQUIREDDISHWASHER - NEED ONE / WHERE? NO3/25/15 - TR/JC NOT REQUIREDREFRIDGERATOR OR FREEZER? YES U.C. REFRIGERATORMICROWAVE NO35FLAMMABLE STORAGE CABINET48"H X 24"W X 24" DEEP34SHOP VAC RIGIDOWNER OWNER PLUG-IN33UNDERCOUNTER REFRIDGERATOR GEFIRST FLOOR: SHELLFISHPROPOGATION AREA100OWNER OWNER PLUG-IN32POWER WASHERS DEWALTDXPW3835 PRESSUREWASHER 3800 PSI @ 3.5GPM, DIRECT DRIVE28"H X 24"W X 38"LFIRST FLOOR: SHELLFISHPROPOGATION AREA100 125 LBS 2 OWNER OWNER N/A31SPAWN TABLE BY OWNER 3' X 6' 3' ???OWNER OWNER30POST SET BAG2' DIAM? X 60"HOWNER OWNER29ALGAE TANK18" DIAM X 60"H FIRST FLOOR: BROOD ROOM 100E 3 OWNER OWNER28SOLENOID VALVE MILWAUKEEMA955 CO2 SOLENOIDVALVEFIRST FLOOR: POST SET 100C 1 OWNER OWNER PLUG-INCES 2014-12-22 10.08.1827CO2 SOLENOID DIAPHRAM VALVE MILWAUKEE MA957 CO2 REGULATOR FIRST FLOOR: POST SET 100C 1 OWNER OWNER PLUG-INCES 2014-12-22 10.08.1826DIGITAL RECYCLING TIMER GREYSENTINELHTTP://GROWGPS.COM/PRODUCTS/DRT1/DRT-1 FIRST FLOOR: POST SET 100C 1 OWNER OWNER PLUG-INCES 2014-12-22 09.17.40DISCONTINUED 120 VOLT, 15-AMP POWER SUPPLY.PLUG THE POWER CABLE INTO A STANDARD NEMA5-15 WALL OUTLET.25pH METER GREEN MILWAUKEE SMS 122 (PORTABLE) FIRST FLOOR: POST SET 100C 1 OWNER OWNER PLUG-IN 115 2CES 2014-12-22 09.17.4024POST SET BLOWER SWEETWATER BY PENTAIR; PENTAIRAES.COM S-21, 1/3 hp 10"H X 9"W FIRST FLOOR: POST SET 100C 28 1 OWNER OWNER8' POWER CORD (CONFIRM IF PLUG OR IFHARDWIRE)115 1 3.8CES 2014-12-22 09.13.5823PUMP PACER SE3LB Css FIRST FLOOR: LARVAL ROOM 100A 1 OWNER OWNER HARDWIRECES 2014-12-22 11.36.29280 GPM, REQUIRES 5 HP, MAXIMUM SUCTION LIFTOF 25 FT22OXYGEN TANKFIRST FLOOR: ALGEA AREA 100B 1 OWNER OWNER N/ACES 2014-12-22 11.11.4021SOLENOID VALVE MILWAUKEEMA955 CO2 SOLENOIDVALVEFIRST FLOOR: ALGEA AREA 100B 1 OWNER OWNER PLUG-INCES 2014-12-22 10.08.1820CO2 SOLENOID DIAPHRAM VALVE MILWAUKEE MA957 CO2 REGULATOR FIRST FLOOR: ALGEA AREA 100B 1 OWNER OWNER PLUG-INCES 2014-12-22 10.08.1819pH METER GREEN MILWAUKEE SMS 122 (PORTABLE) FIRST FLOOR: ALGEA AREA 100B 1 OWNER OWNER PLUG-IN 115 2CES 2014-12-22 11.11.4018DIGITAL RECYCLING TIMER GREYSENTINELHTTP://GROWGPS.COM/PRODUCTS/DRT1/DRT-1 FIRST FLOOR: ALGEA AREA 100B 1 OWNER OWNER PLUG-INCES 2014-12-22 11.11.40DISCONTINUED 120 VOLT, 15-AMP POWER SUPPLY.PLUG THE POWER CABLE INTO A STANDARD NEMA5-15 WALL OUTLET.17ALRAM / THERMOSTAT / CONTROLLER GREYFIRST FLOOR: SPAWN ROOM 101 1 OWNER OWNER PLUG-INCES 2014-12-22 11.07.0516PUMP JACUZZI CARVIN / A.O. SMITH S7km-S1 SPA PUMP FIRST FLOOR: LARVAL ROOM 100A 1 OWNER OWNER HARDWIRE 115 1 9.8CES 2014-12-22 10.57.2015VERTICAL STOCK FILTERS BLUEFIRST FLOOR: SHELLFISHPROPAGATION AREA100 2 OWNER OWNERCES 2014-12-22 10.15.04 WORKS ON WATER PRESSURE14VERTICAL UV FILTERS BLACKFIRST FLOOR: SHELLFISHPROPAGATION AREA100 2 OWNER OWNERCES 2014-12-22 10.15.0813TRITON II COMMERCIAL SAND FILTER(ALMOND COLOR)PENTAIR WATER POOL AND SPA, INC. TR 100C 38"H X 25" DIAFIRST FLOOR: SHELLFISHPROPAGATION AREA100 325 FILLED 1 OWNER CONTRACTORCES 2014-12-22 10.14.4412DIGITAL RECYCLING TIMER GREYSENTINELHTTP://GROWGPS.COM/PRODUCTS/DRT1/DRT-1 FIRST FLOOR: ALGEA AREA 100BOWNER OWNER PLUG-INCES 2014-12-22 10.08.19DISCONTINUED 120 VOLT, 15-AMP POWER SUPPLY.PLUG THE POWER CABLE INTO A STANDARD NEMA5-15 WALL OUTLET.11LINEAR II DIAPHRAGM AIR PUMP (BLUE SWEETWATER BY PENTAIR; PENTAIRAES.COMFIRST FLOOR: ALGEA AREA 100BOWNER OWNER PLUG-INCES 2014-12-22 10.08.1910PUMP CARVIN / A.O. SMITH100OWNER OWNERCES 2014-12-22 10.15.209LARVAL / BROOD BLOWER SWEETWATER BY PENTAIR; PENTAIRAES.COM S-21, 1/3 hp 10"H X 9"W FIRST FLOOR: LARVAL ROOM 100A 28 1 OWNER OWNER8' POWER CORD (CONFIRM IF PLUG OR IFHARDWIRE)115 1 3.8CES 2014-12-22 11.04.118ALGAE SHELVES (3 TIER, WIRE)4'-0"L X 2'-0"W X 4'-0"H FIRST FLOOR: ALGEA AREA 100B 8 OWNER OWNER7LARVAL TANK3'0"L X 6'-0"W 3'-0"HFIRST FLOOR: SHELLFISHPROPAGATION AREA100 6 OWNER OWNER6BROOD TANK22" X 22" X 26" FIRST FLOOR: BROOD ROOM 10E 8 OWNER OWNER5BROOD STOCK TANK4' DIAMETER BY X'-X" TALLFIRST FLOOR: SHELLFISHPROPAGATION AREA100 1 OWNER CONTRACTOR4AQUATIC HEAT PUMPAQUA LOGIC TITAN HEAT PUMP (WATER COOLEDMARINE DUTY)HP2 41"L X 29.5"W X 54"HSECOND FLOOR: TANK SERVICEROOM204 4 OWNER CONTRACTOR7 208-240 1 57CES 2014-12-22 10.59.27WILL MOST LIKELY NOT BE USED, ELECTRICCONSUMER3PUMP - SEAWATER JACUZZI / A.O. SMITHFIRST FLOOR: SHELLFISHPROPAGATION AREA100 3 OWNER CONTRACTOR HARDWIRE2TRITON II COMMERCIAL SAND FILTER(BLACK COLORPENTAIR WATER POOL AND SPA, INC. TR 60? 38" H X 25" DIAFIRST FLOOR: SHELLFISHPROPAGATION AREA100 1 OWNER CONTRACTORCES 2014-12-22 10.15.081LARGE TANK ACE ROTO-MOLD VT01200SWSS 4' DIAMETER BY 13'-0" TALLFIRST FLOOR: SHELLFISHPROPAGATION AREA100 3 OWNER CONTRACTORCES 2014-12-22 10.14.46ITEM # ITEM NAME MANUFACTURERMODELNUMBERDIMENSIONS(EACH)LOCATION INBUILDINGROOMNUMBERWEIGHT(LBS)QUANTITY FURNISHED BY INSTALLED BYPLUG-IN ORHARD-WIREDkW VOLT PHASE AMPSEA WATER(REQUIREMENTS)POTABLE WATERREQUIREMENTSPHOTO NOTESPOWERREQUIREMENTSEQUIPMENT LIST TOTAL CALCULATED OCCUPANTLOAD33'-8" & 2 STORIESPROPOSED HEIGHT & STORIES40'-0" & 2 STORIESALLOWABLE HEIGHT & STORIESPROPOSED AREA PER STORYFLOOR 1 9000SQ FTFLOOR 29000SQ FTALLOWABLE AREA PER STORYBUILDING AREA (GSF)BUILDING PERIMETERCONSTRUCTION TYPEXXXXACCESSORY USE AREAS (A.U.)FURNACE ROOMS >40K BTU/HR (1 HR)INCIDENTAL USE AREAS (I.U.)304.1GROUP BEXISTING USE GROUPCODE SECTIONDESCRIPTION OR NOTESCODE DESCRIPTION•MASSACHUSETTS STATE BUILDING (780 CMR), 8TH EDITION, BASE VOLUME IBC 2009 (ASAMENDED BY CMR 780)•EXISTING BUILDING CODE OF MASSACHUSETTS (780 CMR, CHAPTER 34)•ACCESSIBILITY CODE: ANSI 117.1, VERSION 2003•ELECTRICAL CODE: INTERNATIONAL ELECTRIC CODE (AS AMMENDED BY 527 CMR 12.00)•MECHANICAL CODE: INTERNATIONAL MECHANICAL CODE•PLUMBING CODE: INTERNATIONAL PLUMBING CODE (AS AMMENDED BY 248 CMR)•ENERGY CONSERVATION CODE:APPLICABLE CODESCODE SUMMARYTYPE VB (IBC 2009)4015 SQ FT194'-10"XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX503PROPOSED USE GROUPGROUP B (NO CHANGE)312.1FLOOR 1 2234SQ FTFLOOR 21810SQ FTFLOOR 1 2234FLOOR 21810TAX MAP NO. 42.1.4 PARCEL NO. 7OVERLAY DISTRICTS - OLD HISTORIC DISTRICT, HARBOR WATERSHED PROTECTION ZONE,DEP WETLANDS ZONE, FEDERAL PROTECTED OPEN SPACE FOR LAND CONSERVATION,WIND DEBRIS IMPACT ZONE, HURRICANE INUNDATION ZONE CAT. 1EXISTING BUILDING DATE - 1936DESIGNATIONS: LOCAL HISTORIC DISTRICT (6/4/1970); NAT'L HISTORIC LANDMARK (11/13/1966;NAT'L REGISTER DISTRICT (11/13/1966); NAT'L REGISTER DISTRICT (9/28/1987).MASSACHUSETTS HISTORICAL COMMISSION - APPROVAL, MHC#RC.48462REGULATORY INFORMATIONZONING - R-40NANTUICKET HISTORIC COMMISSION - APPROVAL, CERTIFICATE # 63602MASSACHUSETTS DEPARTMENT OF ENVIRONMENTAL PROTECTION - FILE # SE48-2777FEMA - ZONE AE (ELEV. 9 FT.), MAP NO. 25019C0087G (EFF. DATE 6/9/2014); PANEL 87 OF 177EXITBUILDINGEXIT20"/36"10033"/44"10020"/44"100EXITACCESSDOOREXITACCESSSTAIROCCUPANT LOADREQUIRED WIDTH / WIDTHPROVIDED(R.W. = OCC. LOAD X.X")EXIT ACCESSCORRIDOREGRESS SYMBOLSOCCUPANT LOADREQUIRED WIDTH / WIDTHPROVIDED(R.W. = OCC. LOAD X.X")OCCUPANT LOADREQUIRED WIDTH / WIDTHPROVIDED(R.W. = OCC. LOAD X.X")2 HOUR FIRE SEPARATION ASSEMBLIES1 HOUR FIRE SEPARATION ASSEMBLIES1/2 HOUR FIRE SEPARATION ASSEMBLIESPARTITION / ENCLOSURE NOTES<5' SEPARATED = 1 HR>5' & <10' SEPARATED = 1 HR>10' & <30' SEPARATED = 1 HRx HRx HRx HRx HRx HRx HR0 HR0 HR0 HR0 HR2 HR0 HR0 HR1/2 HR0 HR0 HR2 HR2 HRTABLE 602TABLE 601TABLE 601TABLE 601TABLE 601TABLE 601TABLE 601FIRE RESISTANCE OF EXTERIORWALLS DUE TO SEPARATIONDISTANCES (N/A)ROOF CONSTRUCTIONFLOOR CONSTRUCTIONNONBEARING WALLSINTERIOR BEARING WALLSEXT. BEARING WALLSSECTIONPROVIDEDREQUIREDREQUIREDSTRUCTUREFIRE RESISTANCERATING BY ELEMENTNOT SHOWN FOR CLARITYCURTAIN WALL U FACTOR - METAL FRAMINGCEILINGSLAB ON GRADE FLOORS, MASS (HEATED SLAB)FLOORS, MASSIECC '09 SEC. 502WALLS ABOVE GRADE, MASSSECTIONPROVIDEDENERGY REQUIREMENTSxxWINDOW U FACTORxxxxxxxxxxIECC '09 SEC. 502IECC '09 SEC. 502IECC '09 SEC. 502IECC '09 SEC. 502IECC '09 SEC. 502IECC '09 SEC. 502IECC '09 SEC. 5020 HR0 HRx HR20 MIN45 MIN90 MIN (TABLE 715.4)LSC 30.3.2.1.1NFPA 13-8.14.10.3 - EXC.4NFPA 13-8.14.10.3 - EXC.4LSC 7.5.1.3.4RISBC 709.1, 709.3-EXC.2RISBC 1022.1RISBC 708.4RISBC 706.1OPENINGPROTECTIVESSECTIONPROVIDEDINCIDENTAL USESLIFE SAFETY CLOSET (N/A)MAIN TELE / DATA ROOM AND TELE / DATA CLOSETSELECTRICAL CLOSETSMAIN ELECTRIC ROOMCORRIDORSFIRE PARTITIONSVERTICAL EXIT ENCLOSURESHAFTS CONNECTING LESS THAN 4 STORIES (N/A)FIRE WALLS (N/A)FIRE SEPARATION REQUIREMENTSx HRx HRx HRx HRx HRx HRx HRx HRx HRN/AN/A1 HR1 HR2 HR1/2 HR1/2 HRREQUIREDEGRESS REQUIREMENTSSECTIONNUMBER OF EXITS REQUIREDTABLE 1015.1MAXIMUM TRAVEL DISTANCEMINIMUM CORRIDOR WIDTH*MINIMUM STAIR WIDTHMINIMUM DOOR WIDTHMAXIMUM DEAD ENDMAXIMUM COMMON PATH OF TRAVEL - BUSINESSTABLE 1016.1-IBC1018.2-SBCTABLE 7.3.3.1-LSCTABLE 7.3.3.1-LSC 1005.1-SBC28.2.5.6-LSC 1018.4-SBC EXPN' 228.2.5.4-LSC 1014.3-SBC EXPN' 4xx MAX200.2"/OCC.3575.3"/OCC.44"*36" MINCOMMON PATH OF TRAVEL (LSC)xx'COMMON PATH OF TRAVEL (RISBC)* 36" EXCEPTION FOR REQUIRED EXIT CAPACITY OF NOT MORE THAN 50 PEOPLEMAXIMUM COMMON PATH OF TRAVEL STORAGE 2 - LOW HAZARD STORAGETABLE42.2.5.1-LSC 1014.3-SBC EXPN' 4xx'1PROVIDEDIBC 2009REQUIREDx"/OCC.xxx"/OCC.x36"36" MIN1234567EDCBAF50 SFRESTROOM102STAIRS1LARGE TANKLARGE TANKLARGE TANKBENCHALGAESHELFSCUBA TANKS ANDWET EQUIPLOCKERS4'- 0" x 13'- 0"4'-0" X ??BROODTANK, TYP.FOR 8FDFD267LARVALBASIN, TYP.FOR 6117818, 19, 20, 21, 2216119?FREE AREA:23.91 SQFTSHOWER10450 SFRESTROOM102STAIRS1STORAGE/WORKROOM103STAIRS2BROOD ROOM101JANITOR'S CLOSET100BSHELLFISHPROPAGATION AREA100STORAGE CLOSETS100ALARGE TANKWORKBENCH/CASEWORK2923829SPAWN TABLEBY OWNER30SPAWNTABLEPOST SET,TYP. FOR 8ALGAESHELFFILTERSTORAGE POWERWASHERSTORAGE22" X22" X 26"3'-0" X 6'-0"X 3'-0"LIGHT WALL,BOTH SIDES3'-0" X 6'-0" X 3'-0"2'-6" D X2'-0" H @4 SHELVESLOCKERSLOCKERS2'-6" D X2'-0" H @4 SHELVES4'- 0" x 13'- 0"4'- 0" x 13'- 0"4'- 0" x 13'- 0"1511511511531424, 25,26, 27, 2830POST SET,TYP. FOR 8LIGHT WALL,BOTH SIDESSPAWN TABLEBY OWNERSPAWN TABLEBY OWNERSMALL TANK5SPAWN TABLEBY OWNER33BELOWCOUNTER34BELOWCOUNTER3234PHASE 11234567EDCBAF347 SFOFFICE201297 SFOFFICE202265 SFTANK SERVICE ROOM204CORRIDOR200CLOSET201ARESTROOM206STAIRS1347 SFOFFICE201297 SFOFFICE202121 SFMECHANICAL205CORRIDOR200CLOSET201ARESTROOM206STAIRS1OPEN TO BELOWGUARDRAIL4.1CLOSET202A4.34.24.4LINE OF HEATERCONSTRAINT229 SFTANK HEATER EQUIP.ROOM203TANK 1TANK 2TANK 3TANK 4ACCESS PANEL(FOR 8 2-INCH PIPES)OPEN TO BELOWOPEN TO BELOWOPEN TO BELOWDESKDESKDESKDESK4' BOOKSHELF4' BOOKSHELF4'BOOKSHELF4' BOOKSHELF7'BOOKSHELF7'BOOKSHELF7'BOOKSHELF7' BOOKSHELFFILE CABINETFILE CABINETFILE CABINETFILECABINET230000.01PHASE 2PHASE 1REVISIONS54321ABCOWNER REVIEWG1.00CODE SUMMARYISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAG1.00Scale: 1/8" = 1'-0"1 PHASED FLOOR PLAN - PROPOSED FIRST FLOOR PLANG1.00Scale: 1/8" = 1'-0"2 PHASED FLOOR PLAN - PROPOSED SECOND FLOOR 2468666884266PARCEL 42.1.4.7MEAN WATERHIGH WATER LINEPARCEL 42.1.4.6PARCEL 42.1.4.9M E A N H IGH W A T E R L IN E BERRY HEIDI L TR2 EASTON STREET LLCU.S. COAST GUARDEASTON STREETCOASTAL DUNEVEGETATED COASTAL DUNECOASTAL DUNECOASTAL DUNEMAJOR INDEXDEPRESSION AREAMAJOR INDEXDEPRESSION AREAUPDOWNNEW ADDITION206 SQ.FT.RE-ORIENTED STAIRATLANTICOCEANATLANTICOCEANBRANDT POINTSHELLFISH FACILITYEXG. BLDG.EXG.BLDG.EXG.BLDG.EXG. BLDG.10'-0"SIDE YARD SETBACK46563 FEET220 FEET436 FEET3 6 8 F E E T 33' - 8"32' - 0"EXISTING DOCKEXISTING STAIRSITE PLAN KEYAREA OF NEW CONSTRUCTIONEXISTING BUILDINGVEGETATED COASTAL DUNE AREAIMPROVED SURFACEMAJOR INDEX DEPRESSION AREATOPOGRAPHIC CONTOUR LINEPARCEL BOUNDARY LINE5MAJOR INDEX DEPRESSION BOUNDARY LINEREVISIONS54321ABCOWNER REVIEWG3.00ARCHITECTURAL SITEPLANISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAG3.00Scale: 1/16" = 1'-0"A5 SITE PLAN - PROPOSED SITE PLAN B5AD3.00B5AD3.01A5AD3.01A5AD3.00024119.701024119.701024119.701024119.701024119.701024119.701024119.701024119.701024119.314024119.314024119.314024119.314024119.314024119.313024119.314024119.314024119.314024119.314024119.314+/- 3'-6" V.I.F.024119.505024119.505024119.505024119.505024119.901017300.01017300.01024119.506024119.315+/- 7'-4 1/2" V.I.F.024119.314024119.314024119.909024119.603024119.905024119.902024119.903024119.904H2OTANKH2OTANK024119.901024119.505024119.505024119.505024119.505024119.507024119.603024119.908017300.01017300.01017300.01024119.603017300.01017300.01024119.603024119.907024119.903024119.603024119.603024119.603024119.603024119.603024119.603024119.603024119.907017300.01017300.01024119.304024119.304024119.909024119.911024119.304024119.305024119.903017300.01024119.313024119.911024119.314017300.011234567EDCBAA5AD3.01aF024119.501024119.303024119.3031' - 1 1/4"MOVE BY OWNER OR GC14" X 26" FORMECH COORD.R+D EXISTING EXTERIORSHEATHING @ NEWADDITION ONLYGRAPHICS KEY- DEMOLITION WORKDOOR AND FRAME TO BE REMOVEDDEMOLITION WORK KEY NOTE; REFER TO KEYNOTE LEGENDEXISTING WALL TO REMAINEXISTING ELEMENT TO BE REMOVED, U.N.O.DOOR,FRAME & WD TRIM TO REMAIN, U.N.O.DELINEATES LIMITED DEMOLITION WORK AREA.NOTES:1. REFER TO MECHANICAL, ELECTRICAL & PLUMBING DRAWINGS FOR DETAILEDSYSTEMS DEMO SCOPE.000000.00REVISIONS54321ABCOWNER REVIEWAD1.01DEMOLITION FLOOR PLAN- FIRST FLOORISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAAD1.01Scale: 1/4" = 1'-0"A5 DEMOLITION - FIRST FLOORDEMOLITION KEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.024119.303 REMOVE (& DISPOSE OF) PORTION OF INTERIOR WALL IN ORDER TO ENLARGE EXISTINGWALL OPENING.024119.304 REMOVE (& DISPOSE OF) GWB SHEATHING AND INSULATION. PRESERVE AND PROTECTFRAMING. ALERT ARCHITECT TO ANY SIGNS OF WATER DAMAGE OR DECAY.024119.305 REMOVE (& DISPOSE OF) WOOD PANELLING. WOOD FRAMING TO REMAIN.024119.306 REMOVE AND DIPOSE EXISTING INFILL.024119.313024119.314 REMOVE (& DISPOSE OF) EXG WALL AND BASE IN ITS ENTIRETY TO INCLUDE ALL ASSOCIATEDMATERIAL AND FRAMING.024119.315 REMOVE (& DISPOSE OF) PORTION OF EXTERIOR WALL TO ACCOMIDATE NEW WINDOW.PREPARE OPENING TO RECEIVE NEW LINTEL, FRAME AND SILL. V.I.F.024119.316 REMOVE (& DISPOSE OF) EXG WALL IN ITS ENTIRETY INCLUDING INTERIOR WINDOWASSEMBLIES AND OTHER ASSOCIATED MATERIALS.024119.317 REMOVE AND DISPOSE EXISTING EXTERIOR SIDING DOWN TO EXISTING SHEATHING ATLIMITS SHOWN024119.401 REMOVE (& DISPOSE OF) EXG GWB/PLASTER CEILING. REMOVE ALL CEILING MTD.LIGHTING/DEVICES.024119.501 REMOVE (& DISPOSE OF) EXISTING WOOD FLOORING TO ACCEPT NEW MEP COMPONENT.COORDINATE WITH STRUCTURAL AND MEP DRAWINGS.024119.505 REMOVE (& DISPOSE OF) EXISTING PLYWOOD AND VINYL FLOORING AND BASE; INCLUDEREMOVAL OF ALL ASSOCIATED MATERIALS, TO INCLUDE WOOD SUBFLOOR, MASTICS, GLUES,& BASE. ORIGINAL WOOD PLANK FLOORING BELOW TO REMAIN.ALERT ARCHITECT TO ANYSIGNS OF WATER DAMAGE OR DECAY.024119.506 REMOVE (& DISPOSE OF) EXISTING VINYL FLOORING AND BASE; INCLUDE REMOVAL OF ALLASSOCIATED MATERIALS TO INCLUDE GLUES, MASTICS, AND BASE. EXISTING WOOD FLOORBELOW TO REMAIN.024119.507 REMOVE (& DISPOSE OF) EXG PLYWOOD FLOORING TO INCLUDE REMOVAL OF ALLASSOCIATED MATERIALS INCLUDING JOISTS AND OTHER STRUCTURAL ITEMS.024119.603 REMOVE & DISCARD EXG DOOR AND FRAME024119.701 REMOVE COMPLETE WINDOW UNIT (TO INCLUDE DISMANTLING OF FRAME & REMOVAL OFSASHES, STORM WINDOWS, SCREENS & HARDWARE); PRESERVE AND PROTECT ADJ. EXT.WALL.024119.803 REMOVE AND DISCARD EXISTING ROOF GUTTER AND DOWNSPOUTS. PREP FOR INSTALLATIONOF NEW GUTTER AND OR DOWNSPOUT.024119.804024119.805 REMOVE AND DISCARD EXG ROOFING; REUSE EXG WOOD SHEATHING. CONTRACTOR TONOTIFY ARCHITECT IF ROT OR DECAY IS FOUND. G.C. SHALL PROTECT BUILDING ENVELOPEDURING THE DURATION OF THE PROJECT.024119.901 REMOVE (& DISPOSE OF) EXG WOOD COLUMN (REFER TO STRUCTURAL DRAWINGS)024119.902 REMOVE (& DISPOSE OF) EXG TOILET. EXISTING PLUMBING CONNECTION TO REMAIN.024119.903 REMOVE (& DISPOSE OF) EXG WALL-MOUNTED EQUIPMENT INCLUDING CHALKBOARDS,WHITEBOARDS, TACKBOARDS, ATTACHED SHELVING, PAPER TOWEL DISPENSERS U.N.O. SEEDEMOLITION DRAWINGS FOR EXTENTS.024119.904 REMOVE (& DISPOSE OF) WOOD SHELVING. SALVAGE MOVEABLE METAL SHELF UNITS FORREUSE,024119.905 REMOVE SINK (IN COUNTER) & FAUCET; EXG PLUMBING CONNECTION TO REMAIN024119.907 REMOVE (& DISPOSE OF) EXG STAIR INCLUDING TREADS, RISERS, HANDRAILS, STRINGERSAND LANDINGS.024119.908 REMOVE (& DISPOSE OF) EXG STAIR INCLUDING TREADS, RISERS, HANDRAILS ANDSTRINGERS. EXG LANDING AND ASSOCIATED STRUCTURE TO REMAIN. REMOVE AND DISCARDHANDRAIL AT LANDING,024119.909 REMOVE MEP EQUIPMENT - REFER TO PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGSFOR ADDITIONAL INFO.024119.910 REMOVE (& DISPOSE OF) EXG LIGHT FIXTURE, SWITCH OR DEVICE. REMOVE (& DISPOSE OF)ALL ASSOCIATED ELECTRICAL WIRING, BOXES AND RACEWAYS.024119.911 REMOVE (& DISPOSE OF) PORTIONS OF EXG STEEL RAIL AS REQUIRED FOR NEW FLOOR.024119.913 REMOVE (& DISPOSE OF) EXG CEILING MOUNTED EQUIPMENT INCLUDING ALL ASSOCIATEDELECTRICAL WIRING. SEE MEP DRAWINGS.024119.914 REMOVE (& DISPOSE OF) EXG STRUCTURAL ELEMENT. REFER TO STRUCTURAL DRAWINGS.024119.915 REMOVE (& DISPOSE OF) EXG CASEWORK IN ITS ENTIRETY. B5AD3.00B5AD3.01A5AD3.01LOWER MEZZANINEUPPER MEZZANINEEL. 18'-8"EL. 19' - 10"OPEN TOBELOWOPEN TOBELOWA5AD3.00024119.507024119.507024119.507024119.507024119.507024119.507024119.507024119.507024119.507024119.507024119.907024119.907024119.603024119.603024119.603024119.314024119.314024119.314024119.316024119.316024119.316024119.314024119.314024119.314024119.314024119.507024119.507024119.316024119.915UPPER MEZZANINE017300.01017300.011234567EDCBAA5AD3.01aF14" X 26" FOR MECHANICALCOORDINATIONEXISTING OPENING TO BELOWEXISTING OPENING TO BELOWGRAPHICS KEY- DEMOLITION WORKDOOR AND FRAME TO BE REMOVEDDEMOLITION WORK KEY NOTE; REFER TO KEYNOTE LEGENDEXISTING WALL TO REMAINEXISTING ELEMENT TO BE REMOVED, U.N.O.DOOR,FRAME & WD TRIM TO REMAIN, U.N.O.DELINEATES LIMITED DEMOLITION WORK AREA.NOTES:1. REFER TO MECHANICAL, ELECTRICAL & PLUMBING DRAWINGS FOR DETAILEDSYSTEMS DEMO SCOPE.000000.00REVISIONS54321ABCOWNER REVIEWAD1.02DEMOLITION FLOOR PLAN- MEZZANINEISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MADEMOLITION KEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.024119.303 REMOVE (& DISPOSE OF) PORTION OF INTERIOR WALL IN ORDER TO ENLARGE EXISTINGWALL OPENING.024119.304 REMOVE (& DISPOSE OF) GWB SHEATHING AND INSULATION. PRESERVE AND PROTECTFRAMING. ALERT ARCHITECT TO ANY SIGNS OF WATER DAMAGE OR DECAY.024119.305 REMOVE (& DISPOSE OF) WOOD PANELLING. WOOD FRAMING TO REMAIN.024119.306 REMOVE AND DIPOSE EXISTING INFILL.024119.313024119.314 REMOVE (& DISPOSE OF) EXG WALL AND BASE IN ITS ENTIRETY TO INCLUDE ALL ASSOCIATEDMATERIAL AND FRAMING.024119.315 REMOVE (& DISPOSE OF) PORTION OF EXTERIOR WALL TO ACCOMIDATE NEW WINDOW.PREPARE OPENING TO RECEIVE NEW LINTEL, FRAME AND SILL. V.I.F.024119.316 REMOVE (& DISPOSE OF) EXG WALL IN ITS ENTIRETY INCLUDING INTERIOR WINDOWASSEMBLIES AND OTHER ASSOCIATED MATERIALS.024119.317 REMOVE AND DISPOSE EXISTING EXTERIOR SIDING DOWN TO EXISTING SHEATHING ATLIMITS SHOWN024119.401 REMOVE (& DISPOSE OF) EXG GWB/PLASTER CEILING. REMOVE ALL CEILING MTD.LIGHTING/DEVICES.024119.501 REMOVE (& DISPOSE OF) EXISTING WOOD FLOORING TO ACCEPT NEW MEP COMPONENT.COORDINATE WITH STRUCTURAL AND MEP DRAWINGS.024119.505 REMOVE (& DISPOSE OF) EXISTING PLYWOOD AND VINYL FLOORING AND BASE; INCLUDEREMOVAL OF ALL ASSOCIATED MATERIALS, TO INCLUDE WOOD SUBFLOOR, MASTICS, GLUES,& BASE. ORIGINAL WOOD PLANK FLOORING BELOW TO REMAIN.ALERT ARCHITECT TO ANYSIGNS OF WATER DAMAGE OR DECAY.024119.506 REMOVE (& DISPOSE OF) EXISTING VINYL FLOORING AND BASE; INCLUDE REMOVAL OF ALLASSOCIATED MATERIALS TO INCLUDE GLUES, MASTICS, AND BASE. EXISTING WOOD FLOORBELOW TO REMAIN.024119.507 REMOVE (& DISPOSE OF) EXG PLYWOOD FLOORING TO INCLUDE REMOVAL OF ALLASSOCIATED MATERIALS INCLUDING JOISTS AND OTHER STRUCTURAL ITEMS.024119.603 REMOVE & DISCARD EXG DOOR AND FRAME024119.701 REMOVE COMPLETE WINDOW UNIT (TO INCLUDE DISMANTLING OF FRAME & REMOVAL OFSASHES, STORM WINDOWS, SCREENS & HARDWARE); PRESERVE AND PROTECT ADJ. EXT.WALL.024119.803 REMOVE AND DISCARD EXISTING ROOF GUTTER AND DOWNSPOUTS. PREP FOR INSTALLATIONOF NEW GUTTER AND OR DOWNSPOUT.024119.804024119.805 REMOVE AND DISCARD EXG ROOFING; REUSE EXG WOOD SHEATHING. CONTRACTOR TONOTIFY ARCHITECT IF ROT OR DECAY IS FOUND. G.C. SHALL PROTECT BUILDING ENVELOPEDURING THE DURATION OF THE PROJECT.024119.901 REMOVE (& DISPOSE OF) EXG WOOD COLUMN (REFER TO STRUCTURAL DRAWINGS)024119.902 REMOVE (& DISPOSE OF) EXG TOILET. EXISTING PLUMBING CONNECTION TO REMAIN.024119.903 REMOVE (& DISPOSE OF) EXG WALL-MOUNTED EQUIPMENT INCLUDING CHALKBOARDS,WHITEBOARDS, TACKBOARDS, ATTACHED SHELVING, PAPER TOWEL DISPENSERS U.N.O. SEEDEMOLITION DRAWINGS FOR EXTENTS.024119.904 REMOVE (& DISPOSE OF) WOOD SHELVING. SALVAGE MOVEABLE METAL SHELF UNITS FORREUSE,024119.905 REMOVE SINK (IN COUNTER) & FAUCET; EXG PLUMBING CONNECTION TO REMAIN024119.907 REMOVE (& DISPOSE OF) EXG STAIR INCLUDING TREADS, RISERS, HANDRAILS, STRINGERSAND LANDINGS.024119.908 REMOVE (& DISPOSE OF) EXG STAIR INCLUDING TREADS, RISERS, HANDRAILS ANDSTRINGERS. EXG LANDING AND ASSOCIATED STRUCTURE TO REMAIN. REMOVE AND DISCARDHANDRAIL AT LANDING,024119.909 REMOVE MEP EQUIPMENT - REFER TO PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGSFOR ADDITIONAL INFO.024119.910 REMOVE (& DISPOSE OF) EXG LIGHT FIXTURE, SWITCH OR DEVICE. REMOVE (& DISPOSE OF)ALL ASSOCIATED ELECTRICAL WIRING, BOXES AND RACEWAYS.024119.911 REMOVE (& DISPOSE OF) PORTIONS OF EXG STEEL RAIL AS REQUIRED FOR NEW FLOOR.024119.913 REMOVE (& DISPOSE OF) EXG CEILING MOUNTED EQUIPMENT INCLUDING ALL ASSOCIATEDELECTRICAL WIRING. SEE MEP DRAWINGS.024119.914 REMOVE (& DISPOSE OF) EXG STRUCTURAL ELEMENT. REFER TO STRUCTURAL DRAWINGS.024119.915 REMOVE (& DISPOSE OF) EXG CASEWORK IN ITS ENTIRETY.AD1.02Scale: 1/4" = 1'-0"A5 DEMOLITION - UPPER/LOWER MEZZANINE PLAN B5AD3.00B5AD3.01A5AD3.01A5AD3.00TYP. FOR ALL 6; R & D FOR NEW DORMERS1234567EDCBAFCUT EXISTING SHEATHINGFOR NEW RIDGE VENT024119.805024119.805024119.805024119.805073113.01073113.01GRAPHICS KEY- DEMOLITION WORKDOOR AND FRAME TO BE REMOVEDDEMOLITION WORK KEY NOTE; REFER TO KEYNOTE LEGENDEXISTING WALL TO REMAINEXISTING ELEMENT TO BE REMOVED, U.N.O.DOOR,FRAME & WD TRIM TO REMAIN, U.N.O.DELINEATES LIMITED DEMOLITION WORK AREA.NOTES:1. REFER TO MECHANICAL, ELECTRICAL & PLUMBING DRAWINGS FOR DETAILEDSYSTEMS DEMO SCOPE.000000.00REVISIONS54321ABCOWNER REVIEWAD1.03DEMOLITION FLOOR PLAN- ROOF PLANISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAAD1.03Scale: 1/4" = 1'-0"A5 DEMOLITION - ROOF PLANDEMOLITION KEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.024119.303 REMOVE (& DISPOSE OF) PORTION OF INTERIOR WALL IN ORDER TO ENLARGE EXISTINGWALL OPENING.024119.304 REMOVE (& DISPOSE OF) GWB SHEATHING AND INSULATION. PRESERVE AND PROTECTFRAMING. ALERT ARCHITECT TO ANY SIGNS OF WATER DAMAGE OR DECAY.024119.305 REMOVE (& DISPOSE OF) WOOD PANELLING. WOOD FRAMING TO REMAIN.024119.306 REMOVE AND DIPOSE EXISTING INFILL.024119.313024119.314 REMOVE (& DISPOSE OF) EXG WALL AND BASE IN ITS ENTIRETY TO INCLUDE ALL ASSOCIATEDMATERIAL AND FRAMING.024119.315 REMOVE (& DISPOSE OF) PORTION OF EXTERIOR WALL TO ACCOMIDATE NEW WINDOW.PREPARE OPENING TO RECEIVE NEW LINTEL, FRAME AND SILL. V.I.F.024119.316 REMOVE (& DISPOSE OF) EXG WALL IN ITS ENTIRETY INCLUDING INTERIOR WINDOWASSEMBLIES AND OTHER ASSOCIATED MATERIALS.024119.317 REMOVE AND DISPOSE EXISTING EXTERIOR SIDING DOWN TO EXISTING SHEATHING ATLIMITS SHOWN024119.401 REMOVE (& DISPOSE OF) EXG GWB/PLASTER CEILING. REMOVE ALL CEILING MTD.LIGHTING/DEVICES.024119.501 REMOVE (& DISPOSE OF) EXISTING WOOD FLOORING TO ACCEPT NEW MEP COMPONENT.COORDINATE WITH STRUCTURAL AND MEP DRAWINGS.024119.505 REMOVE (& DISPOSE OF) EXISTING PLYWOOD AND VINYL FLOORING AND BASE; INCLUDEREMOVAL OF ALL ASSOCIATED MATERIALS, TO INCLUDE WOOD SUBFLOOR, MASTICS, GLUES,& BASE. ORIGINAL WOOD PLANK FLOORING BELOW TO REMAIN.ALERT ARCHITECT TO ANYSIGNS OF WATER DAMAGE OR DECAY.024119.506 REMOVE (& DISPOSE OF) EXISTING VINYL FLOORING AND BASE; INCLUDE REMOVAL OF ALLASSOCIATED MATERIALS TO INCLUDE GLUES, MASTICS, AND BASE. EXISTING WOOD FLOORBELOW TO REMAIN.024119.507 REMOVE (& DISPOSE OF) EXG PLYWOOD FLOORING TO INCLUDE REMOVAL OF ALLASSOCIATED MATERIALS INCLUDING JOISTS AND OTHER STRUCTURAL ITEMS.024119.603 REMOVE & DISCARD EXG DOOR AND FRAME024119.701 REMOVE COMPLETE WINDOW UNIT (TO INCLUDE DISMANTLING OF FRAME & REMOVAL OFSASHES, STORM WINDOWS, SCREENS & HARDWARE); PRESERVE AND PROTECT ADJ. EXT.WALL.024119.803 REMOVE AND DISCARD EXISTING ROOF GUTTER AND DOWNSPOUTS. PREP FOR INSTALLATIONOF NEW GUTTER AND OR DOWNSPOUT.024119.804024119.805 REMOVE AND DISCARD EXG ROOFING; REUSE EXG WOOD SHEATHING. CONTRACTOR TONOTIFY ARCHITECT IF ROT OR DECAY IS FOUND. G.C. SHALL PROTECT BUILDING ENVELOPEDURING THE DURATION OF THE PROJECT.024119.901 REMOVE (& DISPOSE OF) EXG WOOD COLUMN (REFER TO STRUCTURAL DRAWINGS)024119.902 REMOVE (& DISPOSE OF) EXG TOILET. EXISTING PLUMBING CONNECTION TO REMAIN.024119.903 REMOVE (& DISPOSE OF) EXG WALL-MOUNTED EQUIPMENT INCLUDING CHALKBOARDS,WHITEBOARDS, TACKBOARDS, ATTACHED SHELVING, PAPER TOWEL DISPENSERS U.N.O. SEEDEMOLITION DRAWINGS FOR EXTENTS.024119.904 REMOVE (& DISPOSE OF) WOOD SHELVING. SALVAGE MOVEABLE METAL SHELF UNITS FORREUSE,024119.905 REMOVE SINK (IN COUNTER) & FAUCET; EXG PLUMBING CONNECTION TO REMAIN024119.907 REMOVE (& DISPOSE OF) EXG STAIR INCLUDING TREADS, RISERS, HANDRAILS, STRINGERSAND LANDINGS.024119.908 REMOVE (& DISPOSE OF) EXG STAIR INCLUDING TREADS, RISERS, HANDRAILS ANDSTRINGERS. EXG LANDING AND ASSOCIATED STRUCTURE TO REMAIN. REMOVE AND DISCARDHANDRAIL AT LANDING,024119.909 REMOVE MEP EQUIPMENT - REFER TO PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGSFOR ADDITIONAL INFO.024119.910 REMOVE (& DISPOSE OF) EXG LIGHT FIXTURE, SWITCH OR DEVICE. REMOVE (& DISPOSE OF)ALL ASSOCIATED ELECTRICAL WIRING, BOXES AND RACEWAYS.024119.911 REMOVE (& DISPOSE OF) PORTIONS OF EXG STEEL RAIL AS REQUIRED FOR NEW FLOOR.024119.913 REMOVE (& DISPOSE OF) EXG CEILING MOUNTED EQUIPMENT INCLUDING ALL ASSOCIATEDELECTRICAL WIRING. SEE MEP DRAWINGS.024119.914 REMOVE (& DISPOSE OF) EXG STRUCTURAL ELEMENT. REFER TO STRUCTURAL DRAWINGS.024119.915 REMOVE (& DISPOSE OF) EXG CASEWORK IN ITS ENTIRETY. MEAN WATER LINEEL. 1' - 4"FIRST FLOOREL. 10' - 0"MEZZANINEEL. 18' - 8"ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"MEZZANINE UPPEREL. 19' - 10"ATTIC FLOOREL. 26' - 2"DORMERROOF CUTDORMERROOF CUTDORMERROOF CUT024119.803024119.306017300.01017300.01024119.909024119.701024119.701017300.07017300.01024119.908017300.01017300.01017300.01ALL EXISTING WOOD PILINGS TOREMAIN. SEE STRUCTURAL DRAWINGSFOR EXTENTS OF WORK.EXISTING WOOD DOCK TO REMAIN. SCOPELIMITED TO LOCATIONS THAT INTERSECTWITH NEW WORK. NOTIFY ARCHITECT OFANY ADDITIONAL SCOPE.017300.07260000.01260000.01073113.01073113.01017300.01074625.03024119.804024119.804024119.804GRAPHICS KEY- DEMOLITION WORKDOOR AND FRAME TO BE REMOVEDDEMOLITION WORK KEY NOTE; REFER TO KEYNOTE LEGENDEXISTING WALL TO REMAINEXISTING ELEMENT TO BE REMOVED, U.N.O.DOOR,FRAME & WD TRIM TO REMAIN, U.N.O.DELINEATES LIMITED DEMOLITION WORK AREA.NOTES:1. REFER TO MECHANICAL, ELECTRICAL & PLUMBING DRAWINGS FOR DETAILEDSYSTEMS DEMO SCOPE.000000.00MEAN WATER LINEEL. 1' - 4"FIRST FLOOREL. 10' - 0"MEZZANINEEL. 18' - 8"ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"MEZZANINE UPPEREL. 19' - 10"ATTIC FLOOREL. 26' - 2"DORMERROOF CUTDORMERROOF CUTDORMERROOF CUT017300.01073113.01073113.01024119.805073113.01R + D SHEATHING TO ACCOMODATAENEW RIDGE VENT024119.701024119.701074625.03024119.701024119.908024119.908017300.01017300.01017300.01EXISTING WOOD DOCK017300.01017300.01024119.804024119.804024119.804024119.909024119.317024119.317260000.01230000.02024119.314230000.01REVISIONS54321ABCOWNER REVIEWAD3.00DEMOLITION EXTERIORELEVATIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAAD3.00Scale: 1/4" = 1'-0"B5 DEMOLITION - EAST ELEVATIONDEMOLITION KEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.024119.303 REMOVE (& DISPOSE OF) PORTION OF INTERIOR WALL IN ORDER TO ENLARGE EXISTINGWALL OPENING.024119.304 REMOVE (& DISPOSE OF) GWB SHEATHING AND INSULATION. PRESERVE AND PROTECTFRAMING. ALERT ARCHITECT TO ANY SIGNS OF WATER DAMAGE OR DECAY.024119.305 REMOVE (& DISPOSE OF) WOOD PANELLING. WOOD FRAMING TO REMAIN.024119.306 REMOVE AND DIPOSE EXISTING INFILL.024119.313024119.314 REMOVE (& DISPOSE OF) EXG WALL AND BASE IN ITS ENTIRETY TO INCLUDE ALL ASSOCIATEDMATERIAL AND FRAMING.024119.315 REMOVE (& DISPOSE OF) PORTION OF EXTERIOR WALL TO ACCOMIDATE NEW WINDOW.PREPARE OPENING TO RECEIVE NEW LINTEL, FRAME AND SILL. V.I.F.024119.316 REMOVE (& DISPOSE OF) EXG WALL IN ITS ENTIRETY INCLUDING INTERIOR WINDOWASSEMBLIES AND OTHER ASSOCIATED MATERIALS.024119.317 REMOVE AND DISPOSE EXISTING EXTERIOR SIDING DOWN TO EXISTING SHEATHING ATLIMITS SHOWN024119.401 REMOVE (& DISPOSE OF) EXG GWB/PLASTER CEILING. REMOVE ALL CEILING MTD.LIGHTING/DEVICES.024119.501 REMOVE (& DISPOSE OF) EXISTING WOOD FLOORING TO ACCEPT NEW MEP COMPONENT.COORDINATE WITH STRUCTURAL AND MEP DRAWINGS.024119.505 REMOVE (& DISPOSE OF) EXISTING PLYWOOD AND VINYL FLOORING AND BASE; INCLUDEREMOVAL OF ALL ASSOCIATED MATERIALS, TO INCLUDE WOOD SUBFLOOR, MASTICS, GLUES,& BASE. ORIGINAL WOOD PLANK FLOORING BELOW TO REMAIN.ALERT ARCHITECT TO ANYSIGNS OF WATER DAMAGE OR DECAY.024119.506 REMOVE (& DISPOSE OF) EXISTING VINYL FLOORING AND BASE; INCLUDE REMOVAL OF ALLASSOCIATED MATERIALS TO INCLUDE GLUES, MASTICS, AND BASE. EXISTING WOOD FLOORBELOW TO REMAIN.024119.507 REMOVE (& DISPOSE OF) EXG PLYWOOD FLOORING TO INCLUDE REMOVAL OF ALLASSOCIATED MATERIALS INCLUDING JOISTS AND OTHER STRUCTURAL ITEMS.024119.603 REMOVE & DISCARD EXG DOOR AND FRAME024119.701 REMOVE COMPLETE WINDOW UNIT (TO INCLUDE DISMANTLING OF FRAME & REMOVAL OFSASHES, STORM WINDOWS, SCREENS & HARDWARE); PRESERVE AND PROTECT ADJ. EXT.WALL.024119.803 REMOVE AND DISCARD EXISTING ROOF GUTTER AND DOWNSPOUTS. PREP FOR INSTALLATIONOF NEW GUTTER AND OR DOWNSPOUT.024119.804024119.805 REMOVE AND DISCARD EXG ROOFING; REUSE EXG WOOD SHEATHING. CONTRACTOR TONOTIFY ARCHITECT IF ROT OR DECAY IS FOUND. G.C. SHALL PROTECT BUILDING ENVELOPEDURING THE DURATION OF THE PROJECT.024119.901 REMOVE (& DISPOSE OF) EXG WOOD COLUMN (REFER TO STRUCTURAL DRAWINGS)024119.902 REMOVE (& DISPOSE OF) EXG TOILET. EXISTING PLUMBING CONNECTION TO REMAIN.024119.903 REMOVE (& DISPOSE OF) EXG WALL-MOUNTED EQUIPMENT INCLUDING CHALKBOARDS,WHITEBOARDS, TACKBOARDS, ATTACHED SHELVING, PAPER TOWEL DISPENSERS U.N.O. SEEDEMOLITION DRAWINGS FOR EXTENTS.024119.904 REMOVE (& DISPOSE OF) WOOD SHELVING. SALVAGE MOVEABLE METAL SHELF UNITS FORREUSE,024119.905 REMOVE SINK (IN COUNTER) & FAUCET; EXG PLUMBING CONNECTION TO REMAIN024119.907 REMOVE (& DISPOSE OF) EXG STAIR INCLUDING TREADS, RISERS, HANDRAILS, STRINGERSAND LANDINGS.024119.908 REMOVE (& DISPOSE OF) EXG STAIR INCLUDING TREADS, RISERS, HANDRAILS ANDSTRINGERS. EXG LANDING AND ASSOCIATED STRUCTURE TO REMAIN. REMOVE AND DISCARDHANDRAIL AT LANDING,024119.909 REMOVE MEP EQUIPMENT - REFER TO PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGSFOR ADDITIONAL INFO.024119.910 REMOVE (& DISPOSE OF) EXG LIGHT FIXTURE, SWITCH OR DEVICE. REMOVE (& DISPOSE OF)ALL ASSOCIATED ELECTRICAL WIRING, BOXES AND RACEWAYS.024119.911 REMOVE (& DISPOSE OF) PORTIONS OF EXG STEEL RAIL AS REQUIRED FOR NEW FLOOR.024119.913 REMOVE (& DISPOSE OF) EXG CEILING MOUNTED EQUIPMENT INCLUDING ALL ASSOCIATEDELECTRICAL WIRING. SEE MEP DRAWINGS.024119.914 REMOVE (& DISPOSE OF) EXG STRUCTURAL ELEMENT. REFER TO STRUCTURAL DRAWINGS.024119.915 REMOVE (& DISPOSE OF) EXG CASEWORK IN ITS ENTIRETY.AD3.00Scale: 1/4" = 1'-0"A5 DEMOLITION - ELEVATION - WEST MEAN WATER LINEEL. 1' - 4"FIRST FLOOREL. 10' - 0"MEZZANINEEL. 18' - 8"ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"MEZZANINE UPPEREL. 19' - 10"ATTIC FLOOREL. 26' - 2"017300.01017300.01017300.01017300.01017300.01024119.909024119.909024119.908024119.909024119.805073113.01073113.01073113.01024119.314MEAN WATER LINEEL. 1' - 4"FIRST FLOOREL. 10' - 0"MEZZANINEEL. 18' - 8"ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"MEZZANINE UPPEREL. 19' - 10"ATTIC FLOOREL. 26' - 2"024119.805017300.01ROOF FASCIACORNICE017300.07260000.01024119.805017300.01024119.603017300.01017300.01024119.909017300.01017300.01017300.01017300.01024119.805E1073113.01073113.01073113.01024119.314GRAPHICS KEY- DEMOLITION WORKDOOR AND FRAME TO BE REMOVEDDEMOLITION WORK KEY NOTE; REFER TO KEYNOTE LEGENDEXISTING WALL TO REMAINEXISTING ELEMENT TO BE REMOVED, U.N.O.DOOR,FRAME & WD TRIM TO REMAIN, U.N.O.DELINEATES LIMITED DEMOLITION WORK AREA.NOTES:1. REFER TO MECHANICAL, ELECTRICAL & PLUMBING DRAWINGS FOR DETAILEDSYSTEMS DEMO SCOPE.000000.00REVISIONS54321ABCOWNER REVIEWAD3.01DEMOLITION EXTERIORELEVATIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAAD3.01Scale: 1/4" = 1'-0"A5 DEMOLITION - SOUTH ELEVATIONDEMOLITION KEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.024119.303 REMOVE (& DISPOSE OF) PORTION OF INTERIOR WALL IN ORDER TO ENLARGE EXISTINGWALL OPENING.024119.304 REMOVE (& DISPOSE OF) GWB SHEATHING AND INSULATION. PRESERVE AND PROTECTFRAMING. ALERT ARCHITECT TO ANY SIGNS OF WATER DAMAGE OR DECAY.024119.305 REMOVE (& DISPOSE OF) WOOD PANELLING. WOOD FRAMING TO REMAIN.024119.306 REMOVE AND DIPOSE EXISTING INFILL.024119.313024119.314 REMOVE (& DISPOSE OF) EXG WALL AND BASE IN ITS ENTIRETY TO INCLUDE ALL ASSOCIATEDMATERIAL AND FRAMING.024119.315 REMOVE (& DISPOSE OF) PORTION OF EXTERIOR WALL TO ACCOMIDATE NEW WINDOW.PREPARE OPENING TO RECEIVE NEW LINTEL, FRAME AND SILL. V.I.F.024119.316 REMOVE (& DISPOSE OF) EXG WALL IN ITS ENTIRETY INCLUDING INTERIOR WINDOWASSEMBLIES AND OTHER ASSOCIATED MATERIALS.024119.317 REMOVE AND DISPOSE EXISTING EXTERIOR SIDING DOWN TO EXISTING SHEATHING ATLIMITS SHOWN024119.401 REMOVE (& DISPOSE OF) EXG GWB/PLASTER CEILING. REMOVE ALL CEILING MTD.LIGHTING/DEVICES.024119.501 REMOVE (& DISPOSE OF) EXISTING WOOD FLOORING TO ACCEPT NEW MEP COMPONENT.COORDINATE WITH STRUCTURAL AND MEP DRAWINGS.024119.505 REMOVE (& DISPOSE OF) EXISTING PLYWOOD AND VINYL FLOORING AND BASE; INCLUDEREMOVAL OF ALL ASSOCIATED MATERIALS, TO INCLUDE WOOD SUBFLOOR, MASTICS, GLUES,& BASE. ORIGINAL WOOD PLANK FLOORING BELOW TO REMAIN.ALERT ARCHITECT TO ANYSIGNS OF WATER DAMAGE OR DECAY.024119.506 REMOVE (& DISPOSE OF) EXISTING VINYL FLOORING AND BASE; INCLUDE REMOVAL OF ALLASSOCIATED MATERIALS TO INCLUDE GLUES, MASTICS, AND BASE. EXISTING WOOD FLOORBELOW TO REMAIN.024119.507 REMOVE (& DISPOSE OF) EXG PLYWOOD FLOORING TO INCLUDE REMOVAL OF ALLASSOCIATED MATERIALS INCLUDING JOISTS AND OTHER STRUCTURAL ITEMS.024119.603 REMOVE & DISCARD EXG DOOR AND FRAME024119.701 REMOVE COMPLETE WINDOW UNIT (TO INCLUDE DISMANTLING OF FRAME & REMOVAL OFSASHES, STORM WINDOWS, SCREENS & HARDWARE); PRESERVE AND PROTECT ADJ. EXT.WALL.024119.803 REMOVE AND DISCARD EXISTING ROOF GUTTER AND DOWNSPOUTS. PREP FOR INSTALLATIONOF NEW GUTTER AND OR DOWNSPOUT.024119.804024119.805 REMOVE AND DISCARD EXG ROOFING; REUSE EXG WOOD SHEATHING. CONTRACTOR TONOTIFY ARCHITECT IF ROT OR DECAY IS FOUND. G.C. SHALL PROTECT BUILDING ENVELOPEDURING THE DURATION OF THE PROJECT.024119.901 REMOVE (& DISPOSE OF) EXG WOOD COLUMN (REFER TO STRUCTURAL DRAWINGS)024119.902 REMOVE (& DISPOSE OF) EXG TOILET. EXISTING PLUMBING CONNECTION TO REMAIN.024119.903 REMOVE (& DISPOSE OF) EXG WALL-MOUNTED EQUIPMENT INCLUDING CHALKBOARDS,WHITEBOARDS, TACKBOARDS, ATTACHED SHELVING, PAPER TOWEL DISPENSERS U.N.O. SEEDEMOLITION DRAWINGS FOR EXTENTS.024119.904 REMOVE (& DISPOSE OF) WOOD SHELVING. SALVAGE MOVEABLE METAL SHELF UNITS FORREUSE,024119.905 REMOVE SINK (IN COUNTER) & FAUCET; EXG PLUMBING CONNECTION TO REMAIN024119.907 REMOVE (& DISPOSE OF) EXG STAIR INCLUDING TREADS, RISERS, HANDRAILS, STRINGERSAND LANDINGS.024119.908 REMOVE (& DISPOSE OF) EXG STAIR INCLUDING TREADS, RISERS, HANDRAILS ANDSTRINGERS. EXG LANDING AND ASSOCIATED STRUCTURE TO REMAIN. REMOVE AND DISCARDHANDRAIL AT LANDING,024119.909 REMOVE MEP EQUIPMENT - REFER TO PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGSFOR ADDITIONAL INFO.024119.910 REMOVE (& DISPOSE OF) EXG LIGHT FIXTURE, SWITCH OR DEVICE. REMOVE (& DISPOSE OF)ALL ASSOCIATED ELECTRICAL WIRING, BOXES AND RACEWAYS.024119.911 REMOVE (& DISPOSE OF) PORTIONS OF EXG STEEL RAIL AS REQUIRED FOR NEW FLOOR.024119.913 REMOVE (& DISPOSE OF) EXG CEILING MOUNTED EQUIPMENT INCLUDING ALL ASSOCIATEDELECTRICAL WIRING. SEE MEP DRAWINGS.024119.914 REMOVE (& DISPOSE OF) EXG STRUCTURAL ELEMENT. REFER TO STRUCTURAL DRAWINGS.024119.915 REMOVE (& DISPOSE OF) EXG CASEWORK IN ITS ENTIRETY.AD3.01Scale: 1/4" = 1'-0"B5 DEMOLITION - NORTH ELEVATION B5A3.00A5A3.00B5A3.01A5A3.01A4.01A5A4.00A5A4.01B41234567EDCBAA4.00B5A10.3019' - 0"8' - 6 1/4"10' - 0 1/2"9' - 9 1/4"10' - 3 1/4"9' - 9 3/4"7' - 6"7' - 6"7' - 2"7' - 7"7' - 0"A3A10.01FAPPROXIMATE PERIMETEROF BUILDING ABOVENOTE: REFER TO STRUCTURALDRAWINGS & SPECS FOR WORKOCCURING TO EXISTING PIERS,FRAMING, BRACING, ETC.A7.02A4A7.03A4GRAPHICS KEYKEY NOTE; REFER TO KEYNOTE LEGENDDOOR, FRAME AND TRIMNOTES:1. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, & STRUCTURAL DRAWINGS FORSCOPE OF WORK.000000.00WINDOW, FRAME AND TRIM1EXISTING EQUIPMENT LABEL-SEE SHEET G0.04EXISTING WALL TO REMAINNEW WALL00REVISIONS54321ABCOWNER REVIEWA1.00MEAN WATER LEVEL PLANISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAA1.00Scale: 1/4" = 1'-0"A5 FLOOR PLAN - PROPOSED MEAN WATER LEVELKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)NOTE: ALL MEP EQUIPMENT TO BELOCATED INSIDE OF THE BUILDING B5A3.00A5A3.00B5A3.01A5A3.01A4.01A5A4.00A5A4.01B450 SFRESTROOM102A7.01B51234567EDCBAA4.00B518916151111111STAIRS1A5A7.0017A8.00B5B2A5A8.01A5A2A1A8.00D2D5D4D3061000.03061000.03A10.301LARGE TANKLARGE TANKLARGE TANK2' - 1"4' - 9"BENCHALGAESHELFSCUBA TANKS ANDWET EQUIP4'- 0" x 13'- 0"4'-0" X ??061000.03BROODTANK, TYP.FOR 8FDFD267LARVALBASIN, TYP.FOR 6117818, 19, 20, 21, 221611230' - 9 3/4"7' - 10 1/4"24' - 3"26' - 0"3' - 4 1/8"4' - 10 1/4"30' - 6 1/2"4' - 6 3/8"FREE AREA:23.91 SQFT3' - 8 13/32"1' - 9"1' - 1"0' - 5 29/32"7' - 5 3/4"SHOWER10450 SFRESTROOM102STAIRS1STORAGE/WORKROOM103STAIRS2BROOD ROOM101JANITOR'S CLOSET100BSHELLFISHPROPAGATION AREA100STORAGE CLOSETS100ALARGE TANKWORKBENCH/CASEWORK23829SPAWN TABLEBY OWNER30SPAWNTABLEPOST SET,TYP. FOR 8ALGAESHELFFILTERSTORAGE POWERWASHERSTORAGE22" X22" X 26"3'-0" X 6'-0"X 3'-0"LIGHT WALL,BOTH SIDES3'-0" X 6'-0" X 3'-0"2'-6" D X2'-0" H @4 SHELVES0' - 10"3674A2A10.01A3A10.012'-6" D X2'-0" H @4 SHELVES4'- 0" x 13'- 0"4'- 0" x 13'- 0"4'- 0" x 13'- 0"1511511511531424, 25,26, 27, 2830POST SET,TYP. FOR 8LIGHT WALL,BOTH SIDESSPAWN TABLEBY OWNERSPAWN TABLEBY OWNERSMALL TANK5SPAWN TABLEBY OWNERF33BELOWCOUNTER34BELOWCOUNTER3234230000A3A8.01D4D5D3D27' - 6"7' - 6"7' - 2"7' - 7"7' - 0"9' - 0"8' - 6 1/4"10' - 0 1/2"9' - 9 1/4"10' - 3 1/4"9' - 9 3/4"9' - 5 1/4"220000.08220000.04051200.01051200.01099600.01099600.0112' - 9 3/8"12' - 3 3/4"TYP. FOR 4 INSTANCES5' - 0"1' - 3 1/2"3' - 0"A2A10.10A4A10.10AA10.10B2A10.10104116.010' - 4"29051200.01099600.0153' - 6"C5A7.02A7.02A4C5A7.03A7.03A4GRAPHICS KEYKEY NOTE; REFER TO KEYNOTE LEGENDDOOR, FRAME AND TRIMNOTES:1. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, & STRUCTURAL DRAWINGS FORSCOPE OF WORK.000000.00WINDOW, FRAME AND TRIM1EXISTING EQUIPMENT LABEL-SEE SHEET G0.04EXISTING WALL TO REMAINNEW WALL00REVISIONS54321ABCOWNER REVIEWA1.01FIRST FLOOR PLANISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAA1.01Scale: 1/4" = 1'-0"A5 FLOOR PLAN - PROPOSED FIRST FLOOR PLANKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)NOTE: ALL MEP EQUIPMENT TO BELOCATED INSIDE OF THE BUILDING GRAPHICS KEYKEY NOTE; REFER TO KEYNOTE LEGENDDOOR, FRAME AND TRIMNOTES:1. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, & STRUCTURAL DRAWINGS FORSCOPE OF WORK.000000.00WINDOW, FRAME AND TRIM1EXISTING EQUIPMENT LABEL-SEE SHEET G0.04EXISTING WALL TO REMAINNEW WALL00B5A3.00A5A3.00B5A3.01A5A3.01A4.01A5A4.00A5A4.01B4A7.01B51234567EDCBAA4.00B5A8.00C2C5C3A8.02D2D5D4A8.01B5B2A8.02B4B3A10.301347 SFOFFICE201297 SFOFFICE202265 SFTANK SERVICE ROOM204CORRIDOR200CLOSET201ARESTROOM2069111011A879A6STAIRS1347 SFOFFICE201297 SFOFFICE202121 SFMECHANICAL205CORRIDOR200CLOSET201ARESTROOM2069111011A879A6STAIRS1OPEN TO BELOWGUARDRAIL4.1A3A10.01CLOSET202A4.34.24.43' - 0"2' - 0"1' - 0"LINE OF HEATERCONSTRAINT229 SFTANK HEATER EQUIP.ROOM2032' - 8 1/2"TANK 1TANK 2TANK 3TANK 4ACCESS PANEL(FOR 8 2-INCH PIPES)FB4D3OPEN TO BELOWOPEN TO BELOWOPEN TO BELOWDESKDESKDESKDESK4' BOOKSHELF4' BOOKSHELF4'BOOKSHELF4' BOOKSHELF7'BOOKSHELF7'BOOKSHELF7'BOOKSHELF7' BOOKSHELFFILE CABINETFILE CABINETFILE CABINETFILECABINETB2B3A8.02C5C4C2C3A8.02A5A4A1A2A8.01C4C5C3C2B57' - 6"7' - 6"7' - 2"7' - 7"7' - 0"9' - 0"8' - 6 1/4"10' - 0 1/2"9' - 9 1/4"10' - 3 1/4"9' - 9 3/4"A4A7.00230000.01A5A10.103'-0" GATE3'-0" GATE3'-0" GATE3'-0" GATEGUARDRAILGUARDRAILGUARDRAIL2' - 1 15/16"3' - 0"3' - 0"3' - 0"3' - 0"4' - 5 11/16"1' - 8 31/32"1' - 8 3/16"0' - 8"A7.03A4REVISIONS54321ABCOWNER REVIEWA1.02SECOND FLOOR PLANISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A1.02Scale: 1/4" = 1'-0"A5 FLOOR PLAN - PROPOSED SECOND FLOORNOTE: ALL MEP EQUIPMENT TO BELOCATED INSIDE OF THE BUILDING B5A3.00A5A3.00B5A3.01A5A3.01A4.01A5A4.00A5A4.01B41234567EDCBAA4.00B5A10.301F7' - 6"7' - 6"7' - 2"7' - 7"7' - 0"9' - 0"8' - 6 1/4"10' - 0 1/2"9' - 9 1/4"10' - 3 1/4"9' - 9 3/4"8 1/2" / 12"8 1/2" / 12"8 1/2" / 12"8 1/2" / 12"8 1/2" / 12"8 1/2" / 12"8 1/2" / 12"8 1/2" / 12"8 1/2" / 12"8 1/2" / 12"8 1/2" / 12"8 1/2" / 12"7" / 12"EXISTINGSLOPE7" / 12"7" / 12"7" / 12"EXISTINGSLOPEEXISTINGSLOPEEXISTINGSLOPE073113.03073113.02073113.01073113.02ENTIREROOF AREA073113.024" / 12"EXISTINGSLOPETYP. U.N.O.TYP. U.N.O.073113.01073113.02073113.03GRAPHICS KEYKEY NOTE; REFER TO KEYNOTE LEGENDDOOR, FRAME AND TRIMNOTES:1. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, & STRUCTURAL DRAWINGS FORSCOPE OF WORK.000000.00WINDOW, FRAME AND TRIM1EXISTING EQUIPMENT LABEL-SEE SHEET G0.04EXISTING WALL TO REMAINNEW WALL00REVISIONS54321ABCOWNER REVIEWA1.03ROOF PLANISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A1.03Scale: 1/4" = 1'-0"A5 ROOF PLAN - PROPOSED ROOF PLANNOTE: ALL MEP EQUIPMENT TO BELOCATED INSIDE OF THE BUILDING A4.01A5A4.00A5A4.01B4A7.01B51234567EDCBAA4.00B5A10.301OPEN TO ABOVEA10.01A5STAIR LANDING ABOVESLOPE4"/12"FAAWWAAAAAAAAAAAAAADDDDAA1AA1A1A1 A1EXITEXITEXITEMEMEMEM EMEMEMREMREMA7.03A4RCP GRAPHICS KEYKEY NOTE; REFER TO KEYNOTE LEGENDEXISTING WALL TO REMAINDELINEATES AREA NOT IN PROJECT SCOPE000000.00NEW WALLSUSPENDED DIRECT/INDIRECT FIXTUREPOWER CORD REELDELINEATES LIMITED DEMOLITION WORK AREA.2' X 4' ACOUSTIC CEILING TILEPAINTED GWB CEILINGSUSPENDED DIRECT/INDIRECT PENDANTRECESSED WALL WASHING FIXTURERECESSED GRID FIXTURENOTES:1. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, & FIRE PROTECTION DRAWINGS FOR DETAILED SYSTEMS SCOPE.REVISIONS54321ABCOWNER REVIEWA2.01FIRST FLOOR REFLECTEDCEILING PLANISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A2.01Scale: 1/4" = 1'-0"A5 PROPOSED REFLECTED CEILING PLAN - FIRST FLOOR A4.01A5A4.00A5A4.01B4A7.01B51234567EDCBAA4.00B5A10.301F23000014" SOFFIT VENT TYP., 16" O.C.,LOCATE BETWEEN EXISTINGRAFTERSSLOPING GWBCEILINGSLOPING GWBCEILINGRIDGE LINESLOPING GWBCEILINGSLOPING GWBCEILINGSLOPING GWBCEILINGSLOPING GWBCEILINGSLOPING GWBCEILINGSLOPING GWBCEILINGSLOPING GWBCEILINGSLOPING GWBCEILINGAWAADAB8B4A1A2 A2A2A1SLOPING GWBCEILINGB8 B4 B8 B4OCOCEXITOCOCEM EMEMEMEMA3A7.00RCP GRAPHICS KEYKEY NOTE; REFER TO KEYNOTE LEGENDEXISTING WALL TO REMAINDELINEATES AREA NOT IN PROJECT SCOPE000000.00NEW WALLSUSPENDED DIRECT/INDIRECT FIXTUREPOWER CORD REELDELINEATES LIMITED DEMOLITION WORK AREA.2' X 4' ACOUSTIC CEILING TILEPAINTED GWB CEILINGSUSPENDED DIRECT/INDIRECT PENDANTRECESSED WALL WASHING FIXTURERECESSED GRID FIXTURENOTES:1. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, & FIRE PROTECTION DRAWINGS FOR DETAILED SYSTEMS SCOPE.REVISIONS54321ABCOWNER REVIEWA2.02SECOND FLOORREFLECTED CEILING PLANISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A2.02Scale: 1/4" = 1'-0"A5 PROPOSED REFLECTED CEILING PLAN - SECOND FLOOR MEAN WATER LINEEL. 1' - 4"A4.01A5ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"A4.01B4PROPOSED 2ND FLOOREL. 20' - 10"A7.01B5PROPOSED 1ST FLOOREL. 10' - 4"1111073113.01260000.03260000.03074625.03099113.01074625.01099113.01EXISTING TO REMAIN AT BUMP OUTTYP. @ ALL PEIRS074625.03099113.01073113.01074625.01099113.01062013.04085413.01099113.01062013.04085413.01099113.01062013.04085413.01099113.01062013.04085413.01099113.01074625.03073113.01073113.01074625.03062013.05062013.01062013.05WINDOWAND TRIMWINDOWAND TRIMWINDOWAND TRIMWINDOWAND TRIM222ADDITION AT BUMP OUT099113.01062013.01085413.01085413.01099113.01062013.01085413.01099113.01WINDOWAND TRIMWINDOWAND TRIMWINDOWAND TRIM062013.05074625.03062013.06099113.01062013.06099113.01099113.01099113.01017300.01017300.02TAG ALL BEAMS!!!EXIST.EXIST.12"8 1/2"CONCEALEDCONCEALEDCONCEALED076200.01076200.01076200.01C3A7.02MEAN WATER LINEEL. 1' - 4"A4.01A5ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"A4.01B4PROPOSED 2ND FLOOREL. 20' - 10"A7.01B5085413.01074625.03074625.03260000.03017300.01017300.01PROPOSED 1ST FLOOREL. 10' - 4"REPLACE ALL WINDOW,FRAMES, HEADS,SILLS. RESTORE HISTORIC TRIM FIRSTFLOOR THIS FACADE, AND AS NOTEDELSEWHERE.099113.01074625.01074625.02061000.02099113.01099113.01085413.01085413.01085413.01076200.01ALL EXISTING WOOD PILINGSTO REMAIN. SEE STRUCTURALDRAWINGS FOR EXTENTS OFWORK.EXISTING WOOD DOCK TO REMAIN.SCOPE LIMITED TO LOCATIONS THATINTERSECT WITH NEW WORK. NOTIFYARCHITECT OF ANY ADDITIONAL SCOPE.EXISTING WOOD RAMP TO REMAIN.SCOPE LIMITED TO LOCATIONS THATINTERSECT WITH NEW WORK. NOTIFYARCHITECT OF ANY ADDITIONAL SCOPE.017300.01099113.01017300.02111062013.05062013.05074625.03062013.05073113.01073113.01099113.01099113.01WINDOWAND TRIMWINDOWAND TRIMWINDOWAND TRIMWINDOWAND TRIM099113.01085413.01062013.01WINDOWAND TRIMWINDOWAND TRIMWINDOWAND TRIM074625.03074625.03099113.01085413.01062013.01099113.01085413.01062013.01099113.01085413.01099113.0112221WINDOWAND TRIMTAG ALL BEAMS!!!099113.01099113.01099113.01017300.01017300.02TYP. @ ALL PEIRSEXIST.EXIST.12"8 1/2"076200.01076200.01076200.01CONCEALEDCONCEALEDCONCEALEDC3A7.03GRAPHICS KEYKEY NOTE; REFER TO KEYNOTE LEGENDROOF SLOPENOTES:1. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, & STRUCTURAL DRAWINGS FORSCOPE OF WORK.000000.00ROOF SHINGLE1EXISTING EQUIPMENT LABEL-SEE SHEET G0.04REVISIONS54321ABCOWNER REVIEWA3.00EXTERIOR ELEVATIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAA3.00Scale: 1/4" = 1'-0"B5 PROPOSED - WEST ELEVATIONKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A3.00Scale: 1/4" = 1'-0"A5 PROPOSED - EAST ELEVATION A4.00A5ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"STAIR GROUND PLANEEL. 2' - 0"PROPOSED 2ND FLOOREL. 20' - 10"PROPOSED 1ST FLOOREL. 10' - 4"A4.00B5171074625.03099113.01074625.03074625.03017300.02073113.01073113.01102800LOUVERED AREA: 12.25 SQ.FT.(APPROX 50% FREE AREA)ACCESS PANEL W/ CONCEALED HINGEOFFSET SHAKE VENTILATION PANEL062013.06062013.06099113.01062013.01099113.01062013.01099113.01073113.01074625.03017300.01017300.01017300.01062013.03099113.01104116.01099113.01099113.01062013.05099113.01076200.01CONCEALEDCONCEALED076200.01017300.02PATCH AND REPAIRSHINGLES AS REQUIREDMATCH EXIST. VIFMATCHEXIST. VIFGC REINSTALL017300.02074625.04074625.04074625.04074625.04A5A7.03A7.03A4MEAN WATER LINEEL. 1' - 4"A4.00A5ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"PROPOSED 2ND FLOOREL. 20' - 10"PROPOSED 1ST FLOOREL. 10' - 4"A4.00B591615074625.03099113.01074625.03099113.01099113.01260000.03073113.01073113.01099113.01099113.01017300.01017300.01017300.01017300.01017300.01074625.03099113.01062013.06099113.01062013.06062013.01099113.01074625.03099113.01073113.01062013.01099113.01CONCEALEDCONCEALED076200.01076200.01017300.02074625.04074625.04074625.04074625.04A7.02A4A5A7.02GRAPHICS KEYKEY NOTE; REFER TO KEYNOTE LEGENDROOF SLOPENOTES:1. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, & STRUCTURAL DRAWINGS FORSCOPE OF WORK.000000.00ROOF SHINGLE1EXISTING EQUIPMENT LABEL-SEE SHEET G0.04REVISIONS54321ABCOWNER REVIEWA3.01EXTERIOR ELEVATIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A3.01Scale: 1/4" = 1'-0"B5 PROPOSED - NORTH ELEVATIONA3.01Scale: 1/4" = 1'-0"A5 PROPOSED - SOUTH ELEVATION MEAN WATER LINEEL. 1' - 4"A4.01A5ROOF LEVELEL. 35' - 0"A4.01B4A3A5.00PROPOSED 2ND FLOOREL. 20' - 10"A7.01B5PROPOSED 1ST FLOOREL. 10' - 4"A2A5.01099600.01017300.01017300.01099600.019 1/2" TJI230 @12" O.C. SEE S3.0GRAPHICS KEYKEY NOTE; REFER TO KEYNOTE LEGENDDOOR, FRAME AND TRIMNOTES:1. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, & STRUCTURAL DRAWINGS FORSCOPE OF WORK.000000.00WINDOW, FRAME AND TRIM1EXISTING EQUIPMENT LABEL-SEE SHEET G0.04EXISTING WALL TO REMAINNEW WALL00MEAN WATER LINEEL. 1' - 4"A4.01A5ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"A4.01B4PROPOSED 2ND FLOOREL. 20' - 10"A7.01B5PROPOSED 1ST FLOOREL. 10' - 4"A5A10.01A5A5.01SimC3A7.00REVISIONS54321ABCOWNER REVIEWA4.00BUILDING SECTIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A4.00Scale: 1/4" = 1'-0"A5 BUILDING SECTIONS - LOOKING EASTA4.00Scale: 1/4" = 1'-0"B5 BUILDING SECTION - LOOKING EAST - ADDITION MEAN WATER LINEEL. 1' - 4"A4.00A5ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"PROPOSED 2ND FLOOREL. 20' - 10"PROPOSED 1ST FLOOREL. 10' - 4"A4.00B5230000.01230000.01073113.01074625.03062013.03099113.01076200.01BEHIND SIDING099113.01B4A10.10A7.02A4A7.03A4MEAN WATER LINEEL. 1' - 4"A4.00A5ROOF LEVELEL. 35' - 0"B.O. SHINGLESEL. 8' - 3 3/16"A5A5.00A2A5.00PROPOSED 2ND FLOOREL. 20' - 10"PROPOSED 1ST FLOOREL. 10' - 4"A4.00B5A2A10.20A4A5.01A3A10.20B5A10.10A7.02A4GRAPHICS KEYKEY NOTE; REFER TO KEYNOTE LEGENDDOOR, FRAME AND TRIMNOTES:1. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, & STRUCTURAL DRAWINGS FORSCOPE OF WORK.000000.00WINDOW, FRAME AND TRIM1EXISTING EQUIPMENT LABEL-SEE SHEET G0.04EXISTING WALL TO REMAINNEW WALL00REVISIONS54321ABCOWNER REVIEWA4.01BUILDING SECTIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAA4.01Scale: 1/4" = 1'-0"A5 BUILDING SECTIONS - LOOKING SOUTH - FRONTKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A4.01Scale: 1/4" = 1'-0"B4 BUILDING SECTION - LOOKING SOUTH - BACK B.O. SHINGLESEL. 8' - 3 3/16"PROPOSED 2ND FLOOREL. 20' - 10"PROPOSED 1ST FLOOREL. 10' - 4"1EPOXY FLOORINGFILL EXISTING CAVITY WITH BATT INSULATION5/8" GYPSUM WALL BOARD4" SIPS PANELFILL EXISTING CAVITY WITH BATT INSULATION5/8" GYPSUM WALL BOARD1/2" PLYWOOD SHEATHING AT ALL SHEER WALLSGWB CEILINGEPOXY FLOORINGRESILIENT BASERESILIENT BASE3/4" PLYWOOD SUBFLOOR-SEE STRUCTURALEXISTING WOOD DECKINGEXISTING STRUCTURE3/4" PLYWOOD SUBFLOOR-SEE STRUCTURALNEW DIMENSIONAL FRAMING ABOVE EXISTINGSUBFLOOR-SEE STRUCTURALTJI FLOOR JOISTS-SEESTRUCTURAL FOR SIZING ANDSPACINGLVL LEDGER(TYP)-SEE STRUCTURAL FOR SIZING AND LCOATIONS1/2" PLYWOOD SHEATHING AT ALL SHEER WALLSFILL TRUSS CAVITY WITH BATT INSULATIONB.O. SHINGLESEL. 8' - 3 3/16"PROPOSED 2ND FLOOREL. 20' - 10"7PROPOSED 1ST FLOOREL. 10' - 4"EXISTING CORNICEEXISTING ROOF FASCIATHREE TAB SHINGLE ROOFEXISTING ROOF FRAMINGBOTTOM EDGE OF EXISTING STEEL BEAMCONT. LVL-SEE STRUCTURAL FOR SIZINGEXSITING WOOD STUBLFOOR TO REMAIN2X6 SOLID BLOCKING BETWEEN LVLEPOXY FLOORING4" SIPS PANELFILL EXISTING CAVITY WITH BATT INSULATION5/8" GYPSUM WALL BOARD1/2" PLYWOOD SHEATHING3/4" PLYWOOD SUBFLOOR-SEE STRUCTURALNEW OVERHEAD ROLLING DOOR-SEE SCHEDULEEPOXY FLOORING3/4" PLYWOOD SUBFLOOR-SEE STRUCTURALFIRST FLOOREL. 10' - 0"MEZZANINEEL. 18' - 8"B.O. SHINGLESEL. 8' - 3 3/16"MEZZANINE UPPEREL. 19' - 10"PROPOSED 1ST FLOOREL. 10' - 4"F0852132 X 10 RAFTER(2) 2 X 6 TOP PLATES2 X SOLID BLOCKING(3) 2 X 10 LINTEL W/PLYWOOD SPACES061000.01061000.01061000.01061000.01061000.01(2) 2 X 6 SILL PLATESREVISIONS54321ABCOWNER REVIEWA5.00WALL SECTIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A5.00Scale: 3/4" = 1'-0"A5 WALL SECTION - EAST WALLA5.00Scale: 3/4" = 1'-0"A3 WALL SECTON - SOUTH WALLA5.00Scale: 3/4" = 1'-0"A2 WALL SECTION - ADDITION - WEST WALL FIRST FLOOREL. 10' - 0"MEZZANINEEL. 18' - 8"B.O. SHINGLESEL. 8' - 3 3/16"MEZZANINE UPPEREL. 19' - 10"ATTIC FLOOREL. 26' - 2"PROPOSED 2ND FLOOREL. 20' - 10"7PROPOSED 1ST FLOOREL. 10' - 4"FIRST FLOOREL. 10' - 0"B.O. SHINGLESEL. 8' - 3 3/16"ATTIC FLOOREL. 26' - 2"PROPOSED 2ND FLOOREL. 20' - 10"EPROPOSED 1ST FLOOREL. 10' - 4"PROPOSED 2ND FLOOREL. 20' - 10"1PROPOSED 1ST FLOOREL. 10' - 4"REVISIONS54321ABCOWNER REVIEWA5.01WALL SECTIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MA07/16/15KEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A5.01Scale: 3/4" = 1'-0"A5 DETAIL - ADDITION WALL SECTIONA5.01Scale: 3/4" = 1'-0"A4 DETAIL - WALL SECTION ADDITIONA5.01Scale: 3/4" = 1'-0"A2 DETAIL - WALL SECTION ENTRY GARAGE A7.01B51082200A7.01B2B6A6A7.00C5LANDING 1DNDN1' - 0"1' - 0"1' - 0"3' - 5"3' - 0"1' - 5 1/2"6' - 6 1/8"A7.03A4EXIST. STRUCTURE& FLOOR FRAMINGTO REMAINMAINTAIN CONTINUITY OF 1 HR FIRERATED CONSTRUCTION.096513.010' - 11"1/2" RADIUS0' - 4"NEW SUBFLOOR096723.010' - 7"061000.05A7.01B5A7.01B2B6A6LANDING 1SECOND FLOOR LANDINGDNDN3' - 0"3' - 0"6' - 6"3' - 0"4' - 1 1/4"8' - 0 17/32"3' - 0"3' - 5 5/8"1' - 6 29/32"0' - 2 3/8"3' - 0"1' - 0"A7.03A4A7.01B5WSLOPING GWBCEILINGSLOPING GWBCEILINGREVISIONS54321ABCOWNER REVIEWA7.00STAIR PLANS, SECTIONSAND DETAILSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A7.00Scale: 1/2" = 1'-0"A5 ENLARGED FLOOR PLAN - ENTRY STAIRA7.00Scale: 1 1/2" = 1'-0"C3 STAIR S1 - LANDING/FLOOR TRANSITION DETAILSA7.00Scale: 3" = 1'-0"C5 STAIR S1 - HANDRAIL/GUARDRAIL DETAILSA7.00Scale: 1/2" = 1'-0"A4 STAIR - PROPOSED SECOND FLOORA7.00Scale: 1/2" = 1'-0"A3 REFLECTED CEILING PLAN - STAIR 13' - 2"3' - 1 13/32"A7.03A46A7.03A4A7.01B5PROPOSED 2ND FLOOREL. 20' - 10"PROPOSED 1ST FLOOREL. 10' - 4"60820007' - 8"LINE OF CEILING9' - 0"099123.01099123.01099123.01099123.01C3A7.00092900.06092900.063' - 9"3' - 2"LANDING 1SECOND FLOOR LANDINGA7.03A4REVISIONS54321ABCOWNER REVIEWA7.01STAIR ELEVATIONS ANDSECTIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MA04/15/15A7.01Scale: 1/4" = 1'-0"A6 ELEVATION - STAIR S1 - NORTHA7.01Scale: 1/4" = 1'-0"B6 ELEVATION - STAIR S1 - SOUTHA7.01Scale: 1/4" = 1'-0"B2 ELEVATION - STAIR S1- WESTKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A7.01Scale: 1/2" = 1'-0"B5 BUILDING SECTION - LOOKING SOUTH - MAIN STAIR MEAN WATER LINEEL. 1' - 4"PROPOSED 1ST FLOOREL. 10' - 4"LANDING 17E4' - 6 3/8"4' - 10 1/4"3' - 11 1/4"0' - 5 21/32"0' - 5 29/32"3' - 6"1' - 0"2' - 6"A7.02A4LANDING 1FIRST FLOORMEAN WATER LINEEL. 1' - 4"B.O. SHINGLESEL. 8' - 3 3/16"PROPOSED 1ST FLOOREL. 10' - 4"5' - 5 1/8"3' - 0 1/16"3' - 4 15/32"3' - 7 9/16"3' - 7 25/32"LANDING 1FIRST FLOORMEAN WATER LINEEL. 1' - 4"FIRST FLOOREL. 10' - 0"B.O. SHINGLESEL. 8' - 3 3/16"PROPOSED 1ST FLOOREL. 10' - 4"REVISIONS54321ABCOWNER REVIEWA7.02EXTERIOR SOUTH STAIRPLANS, ELEVATIONS, ANDSECTIONISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MA08/17/15A7.02Scale: 1/2" = 1'-0"C3BUILDING ELEVATION - LOOKING WEST - SOUTH ENTRYSTAIRA7.02Scale: 1/2" = 1'-0"C5 ENLARGED FLOOR PLAN - SOUTH ENTRY STAIRKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A7.02Scale: 1/2" = 1'-0"A4BUILDING SECTION - LOOKING EAST - SOUTH ENTRYSTAIRA7.02Scale: 1/2" = 1'-0"A5 ELEVATION - SOUTH ENTRY STAIR - SOUTH MEAN WATER LINEEL. 1' - 4"STAIR GROUND PLANEEL. 2' - 0"PROPOSED 1ST FLOOREL. 10' - 4"A7.03A48" CONCRETE PADEXISTING STAIRS1BA7.01B2B6A6A7.03A44' - 10"5' - 4"2' - 0"8" CONCRETE PADEXISTING STAIRSMEAN WATER LINEEL. 1' - 4"FIRST FLOOREL. 10' - 0"B.O. SHINGLESEL. 8' - 3 3/16"STAIR GROUND PLANEEL. 2' - 0"PROPOSED 1ST FLOOREL. 10' - 4"2' - 0"0' - 8"EXISTING STAIRS8" CONCRETE PAD6' - 11 3/16"0' - 8"2' - 0"MEAN WATER LINEEL. 1' - 4"B.O. SHINGLESEL. 8' - 3 3/16"STAIR GROUND PLANEEL. 2' - 0"PROPOSED 2ND FLOOREL. 20' - 10"PROPOSED 1ST FLOOREL. 10' - 4"0' - 8"6' - 11 3/16"2' - 0"EXISTING STAIRS8" CONCRETE PADREVISIONS54321ABCOWNER REVIEWA7.03EXTERIOR NORTH STAIRPLANS, ELEVATION,SECTIONISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MA08/17/15A7.03Scale: 1/2" = 1'-0"A5 ELEVATION - NORTH ENTRY STAIR - NORTHA7.03Scale: 1/2" = 1'-0"C5 ENLARGED FLOOR PLAN - NORTH ENTRY STAIRA7.03Scale: 1/2" = 1'-0"C3BUILDING ELEVATION - EAST ELEVATION - NORTH ENTRYSTAIRA7.03Scale: 1/2" = 1'-0"A4BUILDING SECTION - LOOKING WEST - NORTH ENTRYSTAIRKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS) 11092900.07085413.01085413.01085413.01099123.01099123.01POSTSETPOSTSETBROODTANK30SPAWNTABLE30SPAWNTABLE32092900.07099123.01081420.03081420.02092900.08099123.01099123.01092900.07STORAGETANKSTORAGETANKSTORAGETANKSTORAGETANKSTORAGETANKSAND FILTER099123.01092900.08092900.08092900.08092900.08099123.0176542' - 8"102800.01102800.04102800.04220000.01096723.02102800.02102800.03102800.06220000.09102800.05096723.022' - 8"3' - 0"1' - 6"EQEQ8102800.11096723.02099123.01220000.09102800.03096723.02099123.01099123.01102800.06220000.08102800102800.03102800.067102800.06102800.03220000.01102800.01055000.02220000.08102800REVISIONS54321ABCOWNER REVIEWA8.00INTERIOR ELEVATIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A8.00Scale: 1/4" = 1'-0"B5 ELEVATION - SHELLFISH PROPAGATION ROOM - EASTA8.00Scale: 1/4" = 1'-0"B2 ELEVATION - SHELLFISH PROPAGATION ROOM - SOUTHA8.00Scale: 1/4" = 1'-0"A5 ELEVATION - SHELLFISH PROPAGATION ROOM - WESTA8.00Scale: 1/4" = 1'-0"D5 ELEVATION - RESTROOM 102 - EASTA8.00Scale: 1/4" = 1'-0"D4 ELEVATION - RESTROOM 102 - NORTHA8.00Scale: 1/4" = 1'-0"D3 ELEVATION - RESTROOM 102 - SOUTHA8.00Scale: 1/4" = 1'-0"D2 ELEVATION - RESTROOM 102 - WESTA8.00Scale: 1/4" = 1'-0"C5 ELEVATION - RESTROOM 206 - NORTHA8.00Scale: 1/4" = 1'-0"C3 ELEVATION - RESTROOM 206 - WESTA8.00Scale: 1/4" = 1'-0"C2 ELEVATION - RESTROOM 206- EAST1 Date 1 096723.024' - 9"76REMOVE & DISPOSEEXISTING SHAKE SIDING4' - 1 1/2"5' - 8 3/4"4' - 3 3/4"5' - 8 3/4"4' - 4 1/4"5' - 8 3/4"4' - 11 1/2"099123.01096723.029099123.01064100.0183820REVISIONS54321ABCOWNER REVIEWA8.01INTERIOR ELEVATIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A8.01Scale: 1/4" = 1'-0"A5 ELEVATION - STORAGE 103 - EASTA8.01Scale: 1/4" = 1'-0"A3 ELEVATION - STORAGE 103 - WESTA8.01Scale: 1/4" = 1'-0"A2 ELEVATION - STORAGE 103 - SOUTHA8.01Scale: 1/4" = 1'-0"A1 ELEVATION - STORAGE 103 - NORTHA8.01Scale: 1/4" = 1'-0"D5 ELEVATION - BROOD ROOM 101 - EASTA8.01Scale: 1/4" = 1'-0"D4 ELEVATION - BROOD ROOM 101 - NORTHA8.01Scale: 1/4" = 1'-0"D3 ELEVATION - BROOD ROOM 101 - SOUTHA8.01Scale: 1/4" = 1'-0"D2 ELEVATION - BROOD ROOM 101 - WESTA8.01Scale: 1/4" = 1'-0"C5 ELEVATION - MECHANICAL 205 - EASTA8.01Scale: 1/4" = 1'-0"C4 ELEVATION - MECHANICAL 205 - NORTHA8.01Scale: 1/4" = 1'-0"C3 ELEVATION - MECHANICAL 205 - SOUTHA8.01Scale: 1/4" = 1'-0"C2 ELEVATION - MECHANICAL 205 - WESTA8.01Scale: 1/4" = 1'-0"B5 ELEVATION - TANK HEATER EQUIP. ROOM 203 - EASTA8.01Scale: 1/4" = 1'-0"B4 ELEVATION - TANK HEATER EQUIP. ROOM 203 - NORTHA8.01Scale: 1/4" = 1'-0"B3 ELEVATION - TANK HEATER EQUIP. ROOM 203 - SOUTHA8.01Scale: 1/4" = 1'-0"B2 ELEVATION - TANK HEATER EQUIP. ROOM 203 - WEST 119761089A911A1020SALTWATER TANKSREVISIONS54321ABCOWNER REVIEWA8.02INTERIOR ELEVATIONSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MA06/17/15A8.02Scale: 1/4" = 1'-0"A5 ELEVATION - CORRIDOR 200 - EASTA8.02Scale: 1/4" = 1'-0"A4 ELEVATION - CORRIDOR 200 - NORTHA8.02Scale: 1/4" = 1'-0"A2 ELEVATION - CORRIDOR 200 - SOUTHA8.02Scale: 1/4" = 1'-0"A1 ELEVATION - CORRIDOR 200 - WESTKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A8.02Scale: 1/4" = 1'-0"B5 ELEVATION - OFFICE 201 - EASTA8.02Scale: 1/4" = 1'-0"B4 ELEVATION - OFFICE 201 - NORTHA8.02Scale: 1/4" = 1'-0"B3 ELEVATION - OFFICE 201 - SOUTHA8.02Scale: 1/4" = 1'-0"B2 ELEVATION - OFFICE 201 - WESTA8.02Scale: 1/4" = 1'-0"C5 ELEVATION - OFFICE 202 - EASTA8.02Scale: 1/4" = 1'-0"C4 ELEVATION - OFFICE 202 - NORTHA8.02Scale: 1/4" = 1'-0"C3 ELEVATION - OFFICE 202 - SOUTHA8.02Scale: 1/4" = 1'-0"C2 ELEVATION - OFFICE 202 - WESTA8.02Scale: 1/4" = 1'-0"D5 ELEVATION - TANK SERVICE 204 - EASTA8.02Scale: 1/4" = 1'-0"D4 ELEVATION - TANK SERVICE 204 - NORTHA8.02Scale: 1/4" = 1'-0"D3 ELEVATION - TANK SERVICE 204 - SOUTHA8.02Scale: 1/4" = 1'-0"D2 ELEVATION - TANK SERVICE 204 - WEST 2"RE: SCHED.2"RE: SCHED.2"2"RE: SCHED.2"RE: SCHED.2"FRP - PAINTHM - PAINTFRP-AHM-A2' - 10"0' - 8"0' - 4"0' - 6"DB1/4" CLRSAFETYGLAZING1/4" CLRSAFTEYGLAZING"ES SERIES" FRP1' - 8"0' - 8"0' - 8"A"EP SERIES" FRPC"ES SERIES" FRP7' - 0"3' - 0"7' - 0"3' - 0"F7' - 0"3' - 0"WD/PLAMWD/PLAM7' - 0"7' - 0"0' - 8"2' - 6"RE: SCHED.RE: SCHED.E"EP SERIES" FRPOH-DACOORD. W/ ROUGH OPENING+/- 13' - 4"COORDIANTE W/ ROUGH OPENING+/- 9'-0"OH-FAOH-FBV.I.F.9' - 8 1/2"V.I.F.9' - 8"9' - 2"9' - 3"0' - 4"1' - 2 1/2"1' - 3 1/2"0' - 8 1/2"0' - 6"0' - 7"0' - 2"RECESSEDPANELCLEARGLAZINGOH-DBREVISIONS54321ABCOWNER REVIEWA9.00DOOR SCHEDULESISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MADOORFRAMEDOOR AND FRAME SCHEDULEMark Width Height Thickness Material Door Type Finish Frame Type Material Finish Head Detail Jamb Detail Hardware Set Fire Rating1 3' - 0" 6' - 8" 0' - 2" FRP W MFR. FRP-A FRP MFR. 12 3' - 0" 7' - 0" 0' - 1 3/4" FRP 36 MFG. FRP FRP MFR. N/A3 3' - 0" 7' - 0" 0' - 1 3/4" 36N/A4 3' - 0" 6' - 8" 0' - 1 3/4" WD 5 PLAM FRP-B FRP MFR. T.B.D.5 3' - 6" 6' - 8" 0' - 1 3/4" WD 3 PLAM FRP-B FRP MFR. T.B.D.6 3' - 0" 7' - 0" 0' - 1 3/4" WD 36 MFR. HM-A HM PNT. 4 N/A6 3' - 0" 7' - 0" 0' - 1 3/4" 36N/A7 3' - 0" 7' - 0" 0' - 1 3/4" WD F PLAM HM-A HM PNT. 3 N/A7 3' - 0" 7' - 0" 0' - 1 3/4" 36N/A8 3' - 0" 7' - 0" 0' - 1 3/4" FRP C MFR. FRP-A FRP MFR. 3 N/A8 3' - 0" 7' - 0" 0' - 1 3/4" WD F PLAM HM-A HM PNT. 6 N/A9 3' - 0" 7' - 0" 0' - 1 3/4" FRP R MFR. FRP-G FRP MFR. 1 N/A9 3' - 0" 7' - 0" 0' - 1 3/4" WD 36 PLAM HM-A HM PNT. 7 N/A9A 3' - 0" 7' - 0" 0' - 1 3/4" WD F PLAM HM-A HM PNT. 5 N/A10 3' - 0" 7' - 0" 0' - 1 3/4" WD D PLAM HM-A HM PNT. 7 N/A11 3' - 0" 7' - 0" 0' - 1 3/4" WD 36 PLAM HM-A HM PNT. 7 N/A11A 3' - 0" 7' - 0" 0' - 1 3/4" WD F PLAM HM-A HM PNT. 5 N/A15 12' - 11" 8' - 11" 0' - 1 1/2" WD/GL 67 PAINT OH-FA WD PNT. T.B.D. T.B.D.16 12' - 11" 8' - 11" 0' - 1 1/2" WD/GL 67 PAINT OH-FA WD PNT. T.B.D. T.B.D.17 9' - 0" 8' - 11" 0' - 1 1/2" WD/GL DD PAINT OH-FB WD PNT. T.B.D. T.B.D.20 3' - 0" 7' - 0" 0' - 1 3/4" FN/AA9.00Scale: 1/2" = 1'-0"B5 FRAME TYPESTYP. FRAME TYPES:A9.00Scale: 1/2" = 1'-0"B4 DOOR TYPESABBREVIATIONSHMHOLLOW METALPNTPAINTWDWOODSTLSTEELFRSFIRE-RATED SYSTEMTMPTEMPERED GLASS 1/4"FPRGFIRE PROTECTION RATED GLAZINGIGINSULATING GLASSFRPFIBERGLASS REENFORCED PLASTICGENERAL DOOR & FRAME NOTES:1.ALL FRAMES TO BE 16 GA. STEEL MIN; UNLESSNOTED OTHERWISE.2.FOR RATED LOCATIONS CONTRACTOR TOPROVIDE ALL SEALS, GASKETS, AS REQUIRED BY ULLISTING, TYP.3.ADJUST THROAT WIDTH OF DOOR FRAME TOACCOMODATE VARYING PARTITION TYPES.4.NO DOOR TO BE LOWER THAN 6'-8" IN HEIGHT.TYP. DOOR TYPES:KEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A9.00Scale: 1/2" = 1'-0"A3 OVERHEAD DOOR TYPESA9.00Scale: 1/2" = 1'-0"A5 OVERHEAD FRAME TYPESOVERHEAD FRAME TYPES:OVERHEAD DOOR TYPES: ANCHOR CLIPFRAME; REFERSCHEDULEREFER TO DOORTYPESSEALANT EACHSIDE, TYP.PARTITION TYPESEE PARTITION TYPESMETAL FRAMING0' - 1 3/4"0' - 2" UNOEXTEND WALL5/8" INTO FRAME,TYP.FILL HEADER W/CONT. INSULATIONANCHOR CLIPFRAME; REFER TOSCHEDULEREFER TO DOORTYPESSEALANT EACHSIDE, TYP.PARTITION TYPESEE PARTITION TYPESMETAL FRAMINGACOUSTIC BATT.INSULATION; REFERTO PARTITION TYPE2"2 1/8"1 3/4"2" UNORECESS WALL 5/8"INTO FRAME, TYP.ALL JAMBS WITHCONT. INSULATIONANCHOR CLIPFRAME; REFER TOSCHEDULEREFER TO DOORTYPESSEALANT EACHSIDE, TYP.GWB; AS INDICATEDBY PARTITION TYPESEE PARTITION TYPESBUILT-UP WOOD FRAMING0' - 1 3/4"0' - 2" UNORECESS WALL5/8" INTO FRAME,TYP.ANCHOR CLIPFRAME; REFERTO SCHEDULEREFER TO DOORTYPESSEALANT EACHSIDE, TYP.PARTITION TYPESEE PARTITION TYPESWOOD FRAMING2"2 1/8"1 3/4"2" UNORECESS WALL 5/8"INTO FRAME, TYP.REVISIONS54321ABCOWNER REVIEWA9.01DOOR DETAILSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAHEAD DETAILS JAMB DETAILSA9.01Scale: 3" = 1'-0"C5 DR. FRAME - HM/ MTL. GWB - HEADA9.01Scale: 3" = 1'-0"C3 DR. FRAME - HM/ MTL. GWB - JAMBA9.01Scale: 3" = 1'-0"C4 DR. FRAME - HM/ WD. GWB - HEADA9.01Scale: 3" = 1'-0"C2 DR. FRAME - HM/ WD. GWB - JAMBKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS) REVISIONS54321ABCOWNER REVIEWA9.02FINISHESISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MA08/13/15MATERIALS LISTFINISH DESIGNATION TYPE DESCRIPTION MANUFACTURER STYLE COLOR SIZE FINISH LOCATIONEPOXY-1 EPOXY RESIN EPOXY RESIN RBC INDUSTRIES MANUF. TBD MANUF FIRST FLOORPNT-1 PAINT WATERBORNE ACRYLIC EPOXY BENJAMIN MOORE SEMI-GLOSS TBD MANUF HIGH GLOSS WALLSRB-1 STAIR TREAD RUBBER W/ ABRASIVE STRIP ROPPE MANUF. TBD MANUFVCT-1 VINYL COMPOSITION TILE STANDARD EXCELON ARMSTRONG IMPERIAL TEXTURE TBD MANUF MANUF SECOND FLOORWB-1 WALL BASE RESILIENT BASE JOHNSONITE MANUF. TBD 4" WITH VCTROOM FINISH SCHEDULEROOM NAME RM. NO.FLOOR BASE WALLS NORTH WALLS EAST WALLS SOUTH WALLS WEST CEILINGMATL FINISH MATL FINISH MATL FINISH MATL FINISH MATL FINISH MATL FINISH MATL FINISHNot PlacedSTORAGE 9Room 26Room 27Room 28Room 29Room 30Room 31Room 32Room 33Room 34Room 35Room 36Room 37Room 38Room 39Room 40Room 41Room 42Room 43LARVAL ROOM 100A EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBALGAE AREA 100B EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBPOST SET AREA 100C EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBCLOSET 202A EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBCLOSET 203A EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBLARVAE AREA S5 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBSPAWN ROOM S6 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBALGAE AREA S7 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBPOST SET AREA S8 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBLARVAE AREA S9 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBRoom S11 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBFILTER STORAGE AREA S13 EPOXY-1 EPOXY-1PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBFIRST FLOORSHELLFISH PROPAGATION AREA 100 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBSTORAGE CLOSETS 100A EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBJANITOR'S CLOSET 100B EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBBROOD ROOM 101 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBRESTROOM 102 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBSTORAGE/WORKROOM 103 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBSHOWER 104 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBSTAIR S1 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBSTAIR S2 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBSPAWN ROOM S10 EPOXY-1 EPOXY-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBMEZZANINE UPPERCORRIDOR 200 VCT-1 WB-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBOFFICE 201 VCT-1 WB-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBCLOSET 201A VCT-1 WB-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBOFFICE 202 VCT-1 WB-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBCLOSET 202A VCT-1 WB-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBTANK HEATER EQUIP. ROOM 203 VCT-1 WB-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBTANK SERVICE ROOM 204 VCT-1 WB-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBMECHANICAL 205 VCT-1 WB-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWBRESTROOM 206 VCT-1 WB-1 PNT-1 SEMI-GLOSS PNT-1 PNT-1 PNT-1 GWB A4.01A51A10.01A51' - 4"1' - 11 29/32"3' - 5 11/32"0' - 1 3/16"3' - 5 11/32"F230000.01230000.01SINGLE PULL AND RIMCYLINDER WITH PLYWOODMOUNTHCONTINUOUS HINGE2X4 FRAMING AT 16" O.C.SHINGLES TO MATCHSURROUNDING WALL1/2 PLYWOOD1/2 PLYWOOD PAINTED1/2 PYWOOD PAINTED061000.01061000.01061000.01074625.03061000.01061600.01099113.01061600.01099113.01087100.01A4.01A5B.O. SHINGLESEL. 8' - 3 3/16"PROPOSED 2ND FLOOREL. 20' - 10"PROPOSED 1ST FLOOREL. 10' - 4"OPEN TO BELOWBIRD/BEE SCREENCONDENSING UNIT(PUMY-P60NKMU)BLOCKING ASREQUIRED FOR WALLATTACHMENTLOUVER W/BIRD/BEE SCREEN(50% FREE)OFFSET SHAKE SIDINGPANEL W/ BIRD/BEESCREENBLOCKING AS REQUIREDPLATFORM FRAMINGOPERABLE PANEL W/CONCEALED HINGECHANNEL CLIP260000.012-2X6 FRAMING ABOVEOPERABLE PANEL061000.01061000.05061000.01061000.01074625.03089119.014' - 7"083113.01FIRST FLOOREL. 10' - 0"MEZZANINEEL. 18' - 8"B.O. SHINGLESEL. 8' - 3 3/16"MEZZANINE UPPEREL. 19' - 10"PROPOSED 2ND FLOOREL. 20' - 10"PROPOSED 1ST FLOOREL. 10' - 4"A10.01A5OPERABLE WOOD SHAKE PANELW/CONCEALED HINGE4' - 7"PAINTED LOUVER PANELW/ BIRD/BEE SCREEN12 SQ.FT. FREE AREA (50% OPENESS)7' - 6"F074625.03099113.01089119.01087100.010' - 8 1/2"ALIGN WITH 2X4 STUD BEHIND3X3 1/4 PLYWOOD PAINTED0' - 3"0' - 3 1/4"CONTINUOUS HINGE087100.01087100.01062013.03099113.016' - 7 3/8"REVISIONS54321ABCOWNER REVIEWA10.01EXTERIOR DETAILS -CONDENSING UNITADDITIONISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAA10.01Scale: 1/2" = 1'-0"A2 ENLARGED PLAN - CONDENSING UNIT AREAA10.01Scale: 1/2" = 1'-0"A5 SECTION - CONDENSING UNIT AREAA10.01Scale: 1/2" = 1'-0"A3 ELEVATION - CONDENSING UNIT AREA 7CEC7A7EFIRST FLOOREL. 10' - 0"B.O. SHINGLESEL. 8' - 3 3/16"EPROPOSED 1ST FLOOREL. 10' - 4"MEZZANINE UPPEREL. 19' - 10"PROPOSED 2ND FLOOREL. 20' - 10"REVISIONS54321ABCOWNER REVIEWA10.10PLAN & SECTION DETAILSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)A10.10Scale: 1 1/2" = 1'-0"A EXTERIOR DETAIL - GARAGE DOOR CONNECTIONA10.10Scale: 1 1/2" = 1'-0"A4 INTERIOR DETAIL - WALL JOINTA10.10Scale: 1 1/2" = 1'-0"A5 INTERIOR DETAIL - COLUMN ENCLOSUREA10.10Scale: 1 1/2" = 1'-0"B2 CONNECTION - SOUTHEAST CORNERA10.10Scale: 1 1/2" = 1'-0"A2 DETAIL - SOUTHWEST CORNERA10.10Scale: 1 1/2" = 1'-0"B4 EXTERIOR DETAIL - MECH AREAA10.10Scale: 1 1/2" = 1'-0"B5 INTERIOR DETAIL - SECOND FLOOR OPENING 10' - 4"0' - 2"0' - 3"0' - 3"EQEQEQEQEQEQEQ+/- 4' - 1" V.I.F.0' - 4"0' - 2"0' - 2"0' - 4"+/- 5' - 10" V.I.F.NEW DOUBLE HUNG 2" WOODFRAMED IGU. MATCH HISTORICWINDOW CHARACTER, SIZE &PROPORTIONS.+/- 0'-2" V.I.F.UPPER SASHLOWER SASH0' - 1"0' - 1"0' - 1"7/8' MUNTIN TYP.062013.01099113.01085413.01NEW WOOD FRAMED IGU WITHOPERABLE AWNING. MATCHCHARACTER & PROPORTIONSOF EXISTING HISTORICWINDOWS.0' - 1"AEXTERIORINTERIORWOOD BLOCKINGPAINTED GWBNEW PLYWOODSHEATHINGPAINTEDWOOD SHAKEDOUBLE HUNGWOOD FRAMED IGUHISTORICPAINTEDWOOD TRIM FLASHINGWOOD FRAMEV.I.F.REFER TO WALL SCHED.BATT INSULATIONPAINTED WOODCASING TRIM092900.08EXTERIORINTERIORRESTORE EXISTINGWOOD STOOLWOOD BLOCKINGPAINTED GWBPAINTEDWOOD SHAKEWOOD FRAMEDIGURESTORE EXISTINGWOOD SILL FLASHINGNEW PLYWOODSHEATHINGRESTORE EXISITNGWOOD TRIMRESTOREHISTORICPAINTEDWOOD TRIMV.I.F.REFER TO WALL SCHED.BATT INSULATION+/- 0'-1" V.I.F.RESTORE EXISTINGWOOD TRIM061600.01074625.03099113.01085413.01062013.01099113.01EXTERIORINTERIORPAINTEDWOOD TRIMWOOD BLOCKINGPAINTED GWBPAINTEDWOOD SHAKEWOOD FRAMED IGUW/ OPERABLEAWNING FLASHINGREFER TO WALL SCHED.061000.05099123.01076200.01062013.03099123.01061000.05092900.08099123.01074625.03EXTERIORINTERIORWOOD BLOCKINGPAINTED GWBWOOD FRAMED IGUW/ OPERABLECANOPY FLASHINGWOOD STOOLWOOD SILL0' - 1"PAINTED WOODTRIMPAINTED WOODTRIM0' - 1"WOOD TRIMV.I.F.REFER TO WALL SCHEDULE PAINTED WOODTRIMHISTORICPAINTED WOODTRIMDOUBLEHUNG WOODFRAMED IGUWOOD FRAMEFIRST FLOOREL. 10' - 0"ATTIC FLOOREL. 26' - 2"PROPOSED 2ND FLOOREL. 20' - 10"APROPOSED 1ST FLOOREL. 10' - 4"B5A10.30B3A10.30B4A10.30B2A10.30B1A10.30REVISIONS54321ABCOWNER REVIEWA10.30WINDOW DETAILSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAKEYNOTE LEGENDNUMBER NOTE017000.01017300.01 EXISTING TO REMAIN017300.02 PROTECT EXISTING ELEMENT017300.07 PROTECT EXISTING ELEMENT. REMOVE AND RELOCATE AS REQUIRED TO PAINT.051200.01 STRUCTURAL STEEL (REFER TO STRUCTURAL DRAWINGS)055000.02 METAL HANDRAIL ASSEMBLY061000.01 ROUGH FRAMING061000.02 NEW INFILL WALL AT LOCATION OF EXG WALL PENETRATION.061000.03 NEW INFILL WALL AT LOCATION OF EXISITNG WINDOW.061000.04 NEW GWB PARTITION WALL UNDER STAIR. RETURN WALL SO THAT AREA IS FULLY ENCLOSED.061000.05 WOOD BLOCKING AS REQ'D061000.06061600.01 PLYWOOD SHEATHING062013.01 WOOD TRIM TO MATCH EXG HISTORIC TRIM AT EXG WINDOWS062013.03 WOOD TRIM TO MATCH EXG. HISTORIC TRIM062013.04 RESTORE HISTORIC TRIM AT EXG. WINDOWS062013.05 WOOD FASCIA/RAKE TO MATCH HISTORIC062013.06 RESTORE EXG. HISTORIC WOOD TRIM064100.01 SHELVING072100.02 BATT INSULATION072700.02 FLEXIBLE FLASHING/ STRIPS073113.01 NEW 3-TAB RED ASPHALT ROOF SHINGLES073113.02 ROOFING UNDERLAYMENT073113.03 RIDGE VENT CAP074625.01 REPLACE ROTTEN OR OTHERWISE COMPROMISED WOOD SHAKE WITH NEW. NOTIFYARCHITECT OF ANY SIGNS OF WATER DAMAGE BENEATH SIDING. PRIME AND PAINT TOMATCH EXTERIOR.074625.02 NEW SIDING AT LOCATION OF EXG WALL PENETRATION074625.03 WOOD SHINGLE AND SHAKE SIDING074625.04 RIDGE VENT076200.01 FLASHING079200.01 SEALANT081113.01 HOLLOW METAL FRAME081416.01 FLUSH WOOD DOOR081420.02 STEEL REINFORCED OVERHEAD DOOR081420.03 STEEL REINFORCED WOOD SWING DOOR082000 WOOD DOORS AND FRAMES082200 FRP DOORS & FRAMES083113.01 ACCESS DOOR AND FRAME085213 ALUMINUM CLAD WOOD WINDOWS085213.03 SEALANT085213.04 LOW EXPANSION FOAM INSULATION085413.01 NEW WINDOW TO MATCH EXG HISTORIC WINDOW IN PROFILE, PROPORTION ANDCHARACTER.087100.01 DOOR HARDWARE (REFER TO DR SCHED)089119.01 ALUM. LOUVER092900.01 PROVIDE GYPSUM WALL BOARD END TO PARTIALLY DEMOLISHED WALL. SURFACE AND EDGESSHOULD BE SMOOTH AND READY TO ACCEPT PRIMER.092900.04 REGLET & ACESSORIES092900.06 GWB CEILING ASSEMBLY092900.07 GWB SHEATHING OVER EXISTING STRUCTURE092900.08 NEW GWB WALL ASSEMBLY096513.01 RESILIENT BASE; INSTALL AT ALL WALL AND FLOOR JOINTS AND ALONG ALL FIXEDCASEWORK AT KICK.096723.01 EPOXY FLOORING096723.02 INTEGRAL EPOXY WALL APPLICATION099113.01 EXTERIOR PREP, PRIME & PAINT099123.01 INTERIOR PREP, PRIME & PAINT099600.01 HIGH PERFORMANCE PAINTING102800 TOILET, BATH, AND LAUNDRY ACCESSORIES102800.01 TOILET PAPER DISPENSER102800.02 MEDICINE CABINET102800.03 PAPER TOWEL DISPENSER102800.04 GRAB BAR102800.05 SOAP DISPENSER102800.06 RECESSED WASTE RECEPTACLE102800.11 CLOTHES HOOK104116.01 RECESSED "KNOX-BOX" OR EQUAL AS REQUIRED AND APPROVED BY NANTUCKET FIRED DEPT.220000.01 TOILET220000.04 MOP SINK220000.08 SINK AND FAUCET (REFER TO PULMBING DRAWINGS)220000.09 ADA SINK230000 HVAC (*N)(REFER TO MECH. DRAWINGS)230000.01 MECHANICAL (REFER TO MECH. DRAWINGS)230000.02 MECHANICAL, EXISTING TO REMAIN (REFER TO MECH. DRAWINGS)260000.01 ELECTRICAL AND TELEDATA (REFER TO ELEC. DRAWINGS)260000.03 LIGHT FIXTURE (REFER TO ELEC. DRAWINGS)WINDOW SCHEDULETypeMarkRm. NameRm.NumberHeadHeightSill HeightFrameMaterialFrameFinishHeadDetailJambDetail1 PROPAGATION AREA 101 8' - 4 1/2" 2' - 6" WOOD PAINT C6 C31 PROPAGATION AREA 101 8' - 4 1/2" 2' - 6" WOOD PAINT C6 C31 PROPAGATION AREA 101 8' - 4 1/2" 2' - 6" WOOD PAINT C6 C31 STORAGE 103 7' - 10 1/2" 2' - 0" WOOD PAINT C6 C21 STORAGE 103 7' - 10 1/2" 2' - 0" WOOD PAINT C5 C21 STORAGE 103 7' - 10 1/2" 2' - 0" WOOD PAINT C5 C21 STORAGE 103 7' - 10 1/2" 2' - 0" WOOD PAINT C5 C21 STORAGE 103 8' - 4 1/2" 2' - 6" WOOD PAINT C5 C21 STORAGE 103 8' - 4 1/2" 2' - 6" WOOD PAINT C5 C22 OFFICE 202 4' - 2" 0' - 10" WOOD PAINT C4 C12 OFFICE 203 4' - 2" 0' - 10" WOOD PAINT C4 C12 OFFICE 204 4' - 2" 0' - 10" WOOD PAINT C4 C12 OFFICE 204 4' - 2" 0' - 10" WOOD PAINT C4 C12 OFFICE 201 4' - 2" 0' - 10" WOOD PAINT C4 C12 OFFICE 201 4' - 2" 0' - 10" WOOD PAINT C4 C1A10.30Scale: 3/4" = 1'-0"A5 WINDOW TYPE 1A10.30Scale: 3/4" = 1'-0"A3 WINDOW TYPE 2A10.30Scale: 3" = 1'-0"B5 HEAD DETAIL - WINDOW TYPE 1A10.30Scale: 3" = 1'-0"B3 SILL DETAIL - WINDOW TYPE 1A10.30Scale: 3" = 1'-0"B4 HEAD DETAIL - WINDOW TYPE 2A10.30Scale: 3" = 1'-0"B2 SILL DETAIL - WINDOW TYPE 2A10.30Scale: 3" = 1'-0"B1 MEETING RAIL - WINDOW TYPE 1NOTE: IN ALL FIRST FLOOR LOCATIONS, DESIGN INTENTION FOR NEWWINDOWS (TYPE 1) IS TO REPLICATE EXISTING HISTORIC WINDOWS INSIZE, PROPORTION AND CHARACTER. SECOND FLOOR WINDOWS (TYPE 2)SHOULD REPLICATE HISTORIC WINDOWS IN PROPORTION ANDCHARACTER.FIELD VERIFY ALL EXISTING WINDOW DIMENSIONS. WINDOWFABRICATOR TO PROVIDE SHOP DRAWINGS OF WINDOW TYPES 1 & 2.PROVIDE NOTES ON SHOP DRAWINGS WHERE DIMENSIONS DEVIATEFROM EXISTING WINDOW.A10.30Scale: 3/4" = 1'-0"1 SECTION - WINDOW TYPE 1 REVISIONS54321ABCOWNER REVIEWA12.003D REPRESENTATIONS -EXTERIOR VIEWSISSUED FOR BID19 AUGUST 2015RENOVATIONS & ALTERATIONS TOBRANT POINT SHELLFISHFACILITY2A EASTON STREET NANTUCKET, MAA12.00Scale:C5 3D EXTERIOR VIEW FRONTA12.00Scale:A5 3D EXTERIOR VIEW BACK 5-12-2015 5-12-2015 5-12-2015 5-12-2015 5-12-2015 5-12-2015 5-12-2015 5-12-2015 5-12-2015 1234567EDCBAFREMOVE EXISTING TOILET & LAVATORY.MAINTAIN ASSOCIATED WASTE, VENT, H&CWBRANCH PIPING AS REQUIRED FOR CONNECTIONTO NEW FIXTURES.REMOVE EXISTING PROPANE FIRED WATER HEATER.REMOVE ASSOCIATED PIPING CONNECTIONS BACK TONEAREST MAIN AND CAP. REMOVE EXISTING FLUE ANDPATCH EXISTING WALL TO MATCH EXISTING.REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00PD-101FIRST FLOOR PLUMBINGDEMOLITION PLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"1FIRST FLOOR PLUMBING DEMOLITION 1234567EDCBAFMAINTAIN EXISTINGSANITARY VENTTHROUGH ROOFREVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00PD-102SECOND FLOORPLUMBING DEMOLITIONPLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"12ND FLOOR PLUMBING DEMOLITION PLAN 1. THE PLUMBING CONTRACTOR SHALL REMOVE ALL PLUMBING FIXTURES, CARRIERS, TRIM, ACCESSORIES, EQUIPMENT, FLOOR DRAINS AND PIPING AS SHOWN OR INDICATED ON THE DRAWINGS.2. ALL PIPING TO BE REMOVED SHALL BE REMOVED COMPLETELY OR AS OTHERWISE SHOWN OR INDICATED ON DRAWINGS. ALL PIPE HANGERS, SLEEVES, RISER CLAMPS, ETC. SHALL BE REMOVED COMPLETELY WITH PIPING. NO EXISTING HANGER SYSTEMS SHALL BE REUSED FOR NEW PIPING.3. ALL PIPING TO BE REMOVED SHALL BE REMOVED TO BELOW FLOOR, ABOVE CEILING OR IN WALLS BACK TO MAINS OR SHUT OFF VALVES AT MAINS AND PROPERLY CAPPED PER CODE WITHOUT LEAVING DEAD ENDED PIPING.4. NO EQUIPMENT OR DEVICES THAT HAVE BEEN DISCONNECTED AND OR ABANDONED SHALL REMAIN.5. ALL EXISTING PIPING AND EQUIPMENT SHOWN HAS BEEN TAKEN FROM THE BEST AVAILABLE EXISTING INFORMATION. THE DRAWINGS ARE DIAGRAMMATIC AND ALL FIXTURES, PIPING, AND DEVICES MAY NOT BE SHOWN. THE INTENT OF THESE DRAWINGS IS THAT IN ALL AREAS OF RENOVATION THAT THEY ARE REMOVED, WHETHER OR NOT SHOWN (UNLESS INDICATED TO REMAIN).6. THE PLUMBING CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE EXISTING SYSTEMS AND CONDITIONS IN AREAS OF RENOVATION.7. ANY SYSTEMS OR EQUIPMENT TO REMAIN ACTIVE DURING RENOVATION SHALL BE KEPT IN OPERATION BY PROVIDING TEMPORARY PIPING CONNECTIONS AS REQUIRED UNTIL NEW SYSTEMS ARE INSTALLED AND OPERATIONAL.8. THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE OWNER, CM, AND OR GENERAL CONTRACTOR ANY AND ALL PHASING OF THE PLUMBING DEMOLITION WORK IN ORDER TO SATISFY THE CONSTRUCTION SCHEDULE AND OWNERS OCCUPANCY REQUIREMENTS.9. THE PLUMBING CONTRACTOR SHALL ALSO REVIEW THE ARCHITECTURAL DEMOLITON DRAWINGS AS PART OF THIS CONTRACT FOR ADDITIONAL INFORMATION AND REQUIREMENTS.10. ALL SERVICE INTERUPTIONS SHALL BE COORDINATED AND APPROVED WITH THE OWNER A MINIMUM OF 3 DAYS IN ADVANCE PRIOR TO COMMENCEMENT OF ANY WORK.11. THE PLUMBING CONTRACTOR SHALL COORDINATE HIS DEMOLITION WORK WITH THAT OF OTHER TRADES IN ORDER TO AVOID CONFLICTS.12. ANY FIXTURE OR EQUIPMENT TO BE REMOVED AND REUSED OR RETURNED TO OWNER AT OWNERS REQUEST OR AS INDICATED ON DRAWINGS SHALL BE CAREFULLY REMOVED AND STORED TO PREVENT DAMAGE. 1. THESE GENERAL NOTES ARE APPLICABLE TO ALL PLUMBING DRAWINGS. 2. DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL INTENT OF WORK, SEE DETAILS, SCHEDULES AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3. PLUMBING CONTRACTOR MUST REVIEW DRAWINGS OF THE OTHER TRADES AS PART OF THIS CONTRACT FOR ADDITIONAL WORK REQUIRED AND OR COORDINATION OF HIS WORK FOR OPERATIONS OR CONNECTIONS TO OTHER SYSTEM. 4. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR PROVIDING & INSTALLING ALL SERVICES TO HVAC EQUIPMENT INCLUDING BUT NOT LIMITED TO: GAS SUPPLY PIPING CONDENSATE PIPING, COLD WATER MAKE-UP PIPING DRAINS, & CONNECTIONS TO AIR HANDLING UNITS, FAN COIL UNITS, UNIT HEATERS, BOILERS, CHILLERS, ETC. ALSO, DEVICES REQUIRED INCLUDE BACKFLOW PREVENTERS, REGULATORS, UNIONS, TRAPS, & SHUT-OFF VALVES REQUIRED FOR THIS EQUIPMENT. REFER TO HVAC DWGS. FOR ADDITIONAL INFORMATION AND COORDINATION. 5. THE PLUMBING CONTRACTOR SHALL PROVIDE PIPE EXPANSION JOINTS ON PIPING PASSING THRU ALL BUILDING EXPANSION JOINT LOCATIONS AS REQUIRED PER BUILDING CODES WHETHER OR NOT SHOWN ON DRAWINGS. REVIEW ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR EXACT BUILDING EXPANSION JOINT LOCATIONS AND EXPANSION DIMENSIONS. 6. ALL PLUMBING FIXTURES AND EQUIPMENT ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. 7. MAINTAIN ALL H&CW, WASTE AND VENT PIPING TO ALL FIXTURES THAT ARE NOTED TO REMAIN.PLUMBING SYMBOL LEGENDPLUMBING ABBREVIATIONSPLUMBING DEMOLITION LEGENDPLUMBING GENERAL NOTESPLUMBING DEMOLITION GENERAL NOTESPLUMBING FIXTURE CONNECTION SCHEDULEPLUMBING PIPING LEGENDDESCRIPTIONL-1SYMBOLBALL VALVEOS&Y GATE VALVEGATE VALVETHERMOSTATIC MIXING VALVEGLOBE VALVEBALANCING VALVEBUTTERFLY VALVEFIXTURE TYPECONNECT NEW TO EXISTINGPIPE TRAPCLEANOUTCIDESCRIPTIONABBREVIATIONHWHWR HOT WATER RECIRCULATIONCWCOCDFCO FLOOR CLEANOUTCOLD WATERCONDENSATE DRAINFGCOFLSFFEFINISHED GRADE CLEANOUTFINISHED FLOOR ELEVATIONFLOOR SINKFLOOR DRAINFLDCAST IRONHOT WATERROOF DRAINTHERMOSTATIC MIXING VALVESOIL STACKPUMPED CONDENSATE DRAINSANITARYRAIN WATER LEADERREDUCED PRESSURE BACKFLOW PREVENTERRDPCDTMVSANSSRWLRPBPVVTRWCOWHAWTPVENTVENT THRU ROOFWATER HAMMER ARRESTORWASTETRAP PRIMERWALL CLEANOUTREMOVEREXISTING TO BE RELOCATEDEXISTING TO REMAINERETRREMOVE PIPE, FIXTURE OR EQUIPMENTABBREVIATIONDESCRIPTIONVENTWASTECONNECTIONTYPEFIXTURECONNECTION CONNECTIONCOLD WATER HOT WATERCONNECTION1/2" 1/2"1 1/2" 1 1/2"LAVATORYSHOWER--1/2"1/2"SINK (S-1)1 1/2"1 1/2"1/2"1/2"WATER CLOSET2"3"-1/2"NOTES:1. REFER TO ARCHITECTURAL DRAWINGS FOR ALL PLUMBING FIXTURE MOUNTING HEIGHTS.2. ALL PIPE TRAPS AT SINKS AND LAVATORIES SHALL BE CHROME PLATED CAST BRASS WITH SWIVEL JOINT.ABOVE FINISHED FLOORACCESS DOORAFFADBFP BACKFLOW PREVENTERDF DRINKING FOUNTAINDW DIRECT WASTEGPM GALLONS PER MINUTEINV ELEVLAVIWINVERT ELEVATIONLAVATORYINDIRECT WASTEST STORMTYP TYPICALURINALUVS VENT STACKWC WATER CLOSETWASTE AND VENTW&VWS WASTE STACKADA ACCESSIBLE FIXTURE85°F TEMPIDWATER----DOWNDNDIRECTION OF FLOWFLANGEEND CAPUNIONCLEANOUTDROP AND RUNTEE OFF TOP OF PIPETEE OFF BOTTOM OF PIPETEE UPTEE DOWN90° ELBOW UP90° ELBOW DOWNNATURAL GAS ABOVE FLOORSTORM ABOVE FLOOR (SECONDARY)STORM BURIED (PRIMARY)STORM ABOVE FLOOR (PRIMARY)VENTSANITARY WASTE BURIEDSANITARY WASTE ABOVE FLOORHOT WATER RECIRCULATION (110°F)HOT WATER (110°F)SYMBOLCOLD WATERDESCRIPTIONINDIRECT WASTESINK (S-2)1 1/2"2"1/2"1/2"-1/2" 1/2"3" 1 1/2"JANITOR'S SINK-REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00P-000PLUMBINGABBREVIATIONS NOTES& SYMBOLSISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1234567EDCBAF3/4"H&CW UP2"W UP,2"V UPCONNECT NEW 3/4"CWTO EXISTING CWSUPPLY BELOWBUILDINGCO-1CO-1CO-1CO-1L-1WC-1SH-11 1/2"W UP,1/2"CW UPFLD-11/2"CW UP TOS-1. 1 1/2"WFROM S-11 1/2"V UPFROM 3"WFLD-11/2"H&CW DN1/2"CW UP TOS-1. 1 1/2"WFROM S-13"W UP,1/2"CW UP,2"V UPCONNECT NEW1 1/4"PROPANETO EXG SUPPLYBELOW BUILDING1 1/4"PROPANE UPIN WALL1 1/4"PROPANE UPTO MECH ROOMABOVEJS-1S-2SPAWN ROOMS10STAIRS1STORAGE CLOSETS100AJANITOR'S CLOSET100BSTORAGE/WORKROOM103STAIRS2SHOWER104RESTROOM102CONNECT NEW 4"WTO NEW SANITARYMAIN BELOW BUILDING,AHEAD OF NEWEJECTOR STATIONEJECTOR STATIONSP-1CONNECT 2" DISCHARGEFROM SP-1 TO EXISTINGSANITARY MAIN BELOWBUILDINGTP-11/2"CW UPTO TP-1CONNECT NEW 2"V TOEXG VTR3"ø SAN1 1/2"ø SAN3"ø SAN2"ø SAN4"ø SANCO-1RECONNECT NEW TOILET ANDLAV TO EXITING H&CW, WASTEAND VENT PIPING MAINTAINEDDURING DEMOLITIONCONNECT NEW 2"V TOEXG VTR3"ø SAN1 1/2"ø V3"ø SAN1/2"ø CW1/2"ø 110ºF HW2"ø SAN3"ø SAN1/2"ø 110ºF HW2"ø SAN3/4"ø CW3/4"ø CW3/4"ø CW3/4"ø CW1/2"ø CW3"ø SAN1 1/4"ø LPREVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00P-101FIRST FLOOR PLUMBINGPLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"1PLUMBING FIRST FLOOR 1234567EDCBAF1/2"HW DN, 1/2"CW UPFROM BELOW, 1 1/2"W DOWNTO FLOOR BELOW. 1 1/2"V UPS-1WC-1L-1WH-1S-1FLD-13/4"H&CW UP & DN,4"FLUE VENT THROUGHROOF2"V UP1/2"HW DN, 1/2"CW UPFROM BELOW,1 1/2"W DOWN.1 1/2"V UP3"W BELOW FLOOR,2"V UP, 1/2"CWTO WC-1 SUPPLIED FROMFLOOR BELOW1/2"HW DN, 1/2"CW UPFROM BELOW,1 1/2"W DOWN.1 1/2"V UP1 1/4"PROPANE UP FROMBELOW. PROVIDE SUPPLYTO B-1, B-2, WH-1. REFERTO RISER FOR ADDITIONALINFORMATION3"VTROFFICE202OFFICE201CLOSET201ARESTROOM206STAIRS1MECHANICAL205CORRIDOR200TANK SERVICEROOM204TANK HEATEREQUIP. ROOM203CLOSET202ATP-12"ø V1 1/2"ø V1/2"ø 110ºF HW3/4"ø 110ºF HW1/2"ø 110ºF HW3"ø V1 1/2"ø V2"ø VREVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00P-102SECOND FLOORPLUMBING PLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"1PLUMBING 2ND FLOOR LPLPFINISHED GRADEFINISHED GRADEEXISTING BURIED PROPANESUPPLY FROM EXISTINGBURIED TANKEXTERIOR WALLEXISTINGPRESSUREREGULATOREXISTINGVALVESECOND FLOORWH-111/4"PROPANEAT 13"W.C199 MBH1"PROPANEAT 13"W.CREDUCE PRESSUREAT EQUIPMENT(TYPICAL)B-193 MBHREFER TO TYPICAL GASCONNECTION TO EQUIPMENTDETAIL. (TYPICAL)FIRST FLOORB-193 MBHNEW 11/4"PROPANE,CONNECT TO EXGSUPPLY BELOWBUILDINGNEWSHUTOFFVALVE1"PROPANEAT 13"W.CTYPICAL TRAP PRIMER INSTALLATION DETAIL2TYPICAL INDIRECT WASTE PIPING TO FLOOR DRAIN/FLOOR SINK DETAIL4TYPICAL FLOOR DRAIN / FLOOR SINK SERVICE PIPING INSTALLATION DETAIL1TYPICAL SUMP PUMP INSTALLATION DETAIL3PROPANE GAS RISER6NTSSCALE:NTSSCALE:NTSSCALE:NTSSCALE:N.T.S.OF BASIN2'-6"FROM TOP2'-0" MINLC3'-0"4'-0"13 1/4"3"INLETINLETCL(BY PLBG. CONT)#'-#"HIGH LEVEL ALARMFINISHED FLOOR = ##.##'#'-#"PUMP 1TURN ONTURN OFFLEVELBASIN ELEVATION2" SUMP DISCHARGE,3"VENT UPCOLD WATER SUPPLY,SIZE AS INDICATEDON DWGS.1/2"CWBALL VALVEDISTRIBUTION UNIT:2-4 OPENING UNITAS REQUIRED.1/2" TYPE "K" SOFTCOPPER PIPING TOFLOOR DRAINS. INSULTTO PROTECT FROM FREEZINGAS REQUIRED.TRAP PRIMER:PRECISION PRODUCTSMODEL P-1 ORAPPROVED EQUAL1/2"CWCONCRETESTRUCTURAL SLABPIPE SLEEVE(TYPICAL)1/2" TYPE "K" COPPERTRAP MAKE-UP WATERDOWN IN WALL TO FLOORDRAINS(TYPICAL)1/2" TRAP PRIMERCONNECTION ONTAILPIECE(TYPICAL)WASTE PIPING, REFER TOFLOOR PLAN FOR TYPICALSIZES.1/2" TYPE "K" COPPER,BURIED, INSULATE ALL BURIEDTRAP PRIMER PIPING TO PROTECTFROM FREEZING.FINISHED FLOOR ELEVATION1-1/2"VENT RISERBURIED1-1/2"VENT RISERUP (TYPICAL)WALL CONSTRUCTION,ORIENTATION AS DETERMINEDON FLOOR PLANS.FLOOR DRAIN OR FLOORSINK, REFER TO DETAILON THIS DRAWING FOR ADDITIONALINFORMATION.(TYPICAL)APPROX.30" MIN.FLOOR SLAB:REFER TO ARCHITECTURALDRAWINGS FOR THICKNESS.INVERT ELEVATION###''SIMPLEX, SUBMERSIBLE,NON-CLOG PUMP, REFER TOSPECIFICATION ON THISDRAWING FOR ADDITIONALREQUIREMENTS.HOPPER BOTTOMHYDRAULICALLY SEALEDDISCHARGE FLANGE2" BALLCHECK VALVEWIRE HIGH WATER LEVEL PROBEALARM CIRCUIT TO BUILDING'S "DDC"SYSTEM BY TEMPERATURECONTROL CONTRACTOR.HIGH WATER LEVEL PROBE DRYCONTACT IN CONTROL PANEL,PROVIDED BY PANEL MANUFACTURER,INSTALLED BY PLUMBING CONTRACTORHIGH WATER LEVEL PROBEFURNISHED AND INSTALLEDBY BASIN MANUFACTURERHIGH WATER LEVEL PROBEWIRING TO CONTROL PANEL,PROVIDED/INSTALLED BYPLUMBING CONTRACTOR2"GATE VALVE2"DISCHARGEFLASHING ALARM LIGHTSEAL FAILURE LIGHTNOTE:1. ALL FLOOR DRAINS / SINKS SHALL BE PROVIDED WITH TRAP PRIMER CONNECTIONS AND VENT PIPING PER CMR 248. REFER TO FLOOR DRAIN DETAIL FOR ADDITIONAL INFORMATION.2. VERIFY FLOOR CONSTRUCTION TYPE WITH ARCHITECTURAL DRAWINGS AND EXISTING CONDITIONS. MATERIAL SHOWN AS EXAMPLE "ONLY". CONTRACTOR SHALL FIELD VERIFY EXISTING FLOOR TYPE PRIOR TO INSTALLATION.PIPE SIZE ASNOTED ON PLANFINISHED FLOORINDIRECT WASTE LINES2xINLETPIPEDIA.AIR GAPNEMA4X JBOXLOCKINGCLASP (FORPADLOCK BYG.C.)LIFTINGCHAINGATE VALVE EXTENSIONPROVIDED FORDISCHANGE GREATERTHAN 2'-0" FROM TOPOF BASIN.NEMA 4X CONTROLPANEL LOCATEDOFF COVER BYPLUMBINGCONTRACTORMOUNTCONTROLPANEL ONWALL120V/1PHASECONTROL WIRE,PROVIDED ANDINSTALLED BY THEELECTRICALCONTRACTORFLOOR DRAIN INSTALLATIONFLOOR DRAIN DEPRESSION RADIUS OF AREA DRAINED(FEET)5 FT10 FT15 FT20 FT25 FT1/2"3/4"1 1/2"1 1/4"1"(INCHES)REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00P-200PLUMBING DETAILSISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 199,000SYMBOLWH-1ITYPE LOCATION0.4 GPM 9.8 GPM /-0V-0 REMARKS--MANUFACTURER/MODEL NUMBERFUELTYPEBTUHINPUTMINIMUMACTIVATIONFLOW RATEMAX FLOWRATERINNAI MODEL #RUR98i2ND FLRMECH ROOMPROPANEELEC DATAHP-VOLTS-PHNOTES;S = STORAGE TYPE HEATER.I = INSTANTANEOUS TYPE HEATER(WATER HEATER REQUIRES A MINIMUM OF 6"W.C. GAS PRESSURE TO OPERATE)GPM AT75° DELTA-T5.0 GPMPLUMBING FIXTURE SCHEDULEPLUMBING SPECIALTIES SCHEDULEWATER HEATER SCHEDULE-GAS FIREDSUMP PUMP SCHEDULE2. INSTALL PLUMBEREX HANDY-SHIELD MAXX PIPE PROTECTOR ON THE HOT,3. FIXTURES AND TRIM AS NOTED SHALL BE "ACCESSIBLE" AND SHALL BE INSTALLED TO4. PROVIDE LOOSE KEY SUPPLY VALVES AT THE PIPE CONNECTIONS TO FIXTURES.5. PROVIDE WATER HAMMER ARRESTORS (WHA-1) AT THE PIPE CONNECTIONS.1. COLOR SHALL BE WHITE.REMARKS:6. REFER TO FIXTURE CONNECTION SCHEDULE FOR PIPE SIZES TO EACH FIXTURE.ACCESSORIESANDTRIMSYMBOLMODEL NUMBERMANUFACTURER/OF FIXTUREDESCRIPTIONREMARKS COLD, AND DRAIN PIPING UNDER FIXTURE. ADA / ANSI A117 REQUIREMENTS.REMARKSREMARKS:DESCRIPTIONMANUFACTURER/MODEL NUMBERSYMBOLCOMPONENTSANDACCESSORIESVANDAL PROOFMODEL #CO-1JR. SMITHWITH TAPERCAST IRON TEECLEANOUT:THREAD-BRONZESCREWS.# 2VANDAL PROOFWC0-1# 2WALL CLEANOUT:MODEL #JR. SMITH4532S-U4402C-UPLUG.SCREWS.1. PROVIDE ISOLATION VALVES AT THE SUPPLY PIPE CONNECTIONS.2. REFER TO FLOOR PLANS FOR SIZES.3. INSTALL SIZED PER LOAD (WSFU) RECOMMENDED BY PDI & MANUFACTURER.4. THE TRAP PRIMER SHALL BE INSTALLED A MINIMUM OF 1 FOOT ABOVE FINISHED FLOORFOR EVERY 20 FEET OF PRIMER LINE.DUCO CAST IRON,SPIGOT FERRULECAST BRONZETHREAD PLUG,STAINLESS STEELROUND COVER ANDSCREW.#1,2,3,4,6L-1AMERICAN STANDARDMODEL #9141.011LAVATORY:ACCESSIBLE, WALLHUNG, 4" CENTERS,OVERFLOW DRAINCHICAGO FAUCET#895-317 WITH4"CENTERS, 4"BLADEHANDLES K-13885OFFSET GRID DRAIN,KEYED SUPPLYSTOPS, JR SMITH0700 SERIES CARRIERFOR CARPETED-Y CARPET MARKERMODEL #JR. SMITHFCO-1# 2FLOOR CLEANOUT:4023S-NB-U-FCFLOORSCAST IRON BODY,ROUND ADJUSTABLESCORIATED NICKLEBRONZE TOP,FLANGE GASKETINSIDE, CAULKOUTSIDE.VANDAL PROOF &BRONZE PLUGHB-1REMOVABLE KEY3/4" THREADEDHOSE CONNECTIONBRONZE BODY,FREEZE PROOF,VACUUM BREAKER,HOSE BIBB:JR SMITH5609QTSERIES ## 1WC-1#1,3,4,5,6OLSONITE #95SS OPENFRONT, COVERLESS,WHITE SEAT.WATER CLOSET:ACCESSIBLE,FLOOR MOUNTED,ELONGATED BOWL,VITREOUS CHINA,TANK TYPE,1.6 MAX GPF.AMERICANSTANDARD"CADET"MODEL #2998.012SH-1#3,6SHOWER:--RINSE SHOWER,WALLS & FLOORPER ARCHITECTURALDRAWINGSSYMMONS "TEMPTROLII" MODEL #BP-65-1-231,WTIH HAND SHOWERAND FLEX METALHOSE AND SLIDE BAR,VANDAL PROOFSHOWER HEAD. 1.5GPM FLOWRESTRICTOR#2,3,4,6S-1ELKAY"LUSTERTONE"MODEL # LRAD-2219SINK:ACCESSIBLE,COUNTERTOP (4)-4"SPACED FAUCETHOLES, 18 GAUGETYPE 302 SST, SELFRIMMING, 6 1/2"DEEP.SYMMONSSYMMETRIX, CHROMEPLATED FAUCET,EXTRA LONG, SINGLELEVER, 1 GPM, HOSESPRAY, MODEL #S-23-2, CHROMEPLATED GRID DRAINASSEMBLY # LK-8,TP-1# 2,4TRAP PRIMER:PRECISION PLUMBING"PRIME-RITE" MODEL# PR-500INTERNAL VACUUMBREAKER ANDBACKFLOWPREVENTER UNIT.1/2" INLET ANDOUTLETDISTRIBUTION UNITSMODEL #DU-U ASREQUIRED FOR THENUMBER OF FLOORDRAINS SHOWN ONTHE DRAWINGS.# 1,4JS-1SEE REMARK #7FIAT MODEL# MSB-2424JANITORS SINK:MOLDED STONE BASIN,24"x24"x10", SSTINTEGRAL DRAIN BODY.7. PROVIDE WITH FIAT MODEL #830-AA SERVICE FAUCET WITH VACUUM BREAKER, MODEL #1453-BB 16 GAUGE STAINLESS STEEL STRAINER, MODEL #1239-BB ALUMINUM BUMPER GUARD PLATE, MODEL #MSG-3636 WALL GUARD, MODEL #889-CC MOP HANGER, AND MODEL #832 HOSE AND BRACKET. FLOOR MOUNTED DRAIN BODY SHALL BE STAINLESS STEEL CAST INTEGRAL. PROVIDE FOR A CAULKED LEAD CONNECTION NO LESS THAN 1"DEEP FROM DRAIN TO A 3" WASTE PIPE.#2,3,4S-2FIAT MODEL #FL-1SINK:MOLDED STONE,BAKED ENAMEL LEGS,(2)4"-SPACED FAUCETHOLES, 21x23x13"DEEPSYMMONSSYMMETRIX, CHROMEPLATED FAUCET,EXTRA LONG, SINGLELEVER, 1 GPM, HOSESPRAY, MODEL #S-23-2, CHROMEPLATED GRID DRAINASSEMBLY # LK-8,SPBELOWBUILDING0-60 140°F30SP-1SP = SUBMERSIBLE PUMPSYMBOLTYPE LOCATIONMANUFACTURER/MODEL NUMBERCAPACITYFEET OFHEADSYSTEMSERVEDCAPACITYGPMFLUIDTEMP(F°)ELEC DATAHP-VOLT-PHWASTEWATERHYDROMATIC MODEL #HPG200-FBGHRS2460WP2-208V-3 NOTES:1, PUMP PACKAGE SHALL INCLUDE BASIN, CONTROLS, COVER, FLOATS, ETC. REFER TO SPECIFICATIONS FOR MORE INFORMATION.2. BASIN SHALL BE 2' DIA X 5' DEEP.3. PUMP PACKAGE SHALL BE SIMPLEX. THE PLUMBING CONTRACTOR SHALL FURNISH AND PROVIDE ONE ADDITIONAL PUMP TO THE OWNERNOTES#1,2,3REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00P-500PLUMBING SCHEDULESISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1234567EDCBAFTREMOVE EXISTING CEILINGHUNG HOT WATER AIRHANDLING UNIT WITH HOTWATER COIL AND ALLASSOCIATED PIPINGREMOVE EXISTING CEILINGHUNG HOT WATER FURNACEAND ALL ASSOCIATED PIPINGREMOVE EXISTINGPROPANE HEATERAND ASSOCIATEDFLUEREMOVE ALL ABANDONED HOTWATER PIPING1)REFER TO DRAWING M-500 FOR EQUIPMENT SCHEDULE AND DRAWING M-500 FOR EQUIPMENTSYMBOLS, LEGENDS, AND ABBREVIATIONS.2)REMOVE ALL EXISTING MECHANICAL HEATING AND COOLING SYSTEMS, INCLUDING BUT NOTLIMITED TO ALL ASSOCIATED FLUES, PIPING, VALVES, THERMOSTATS, WIRING AND ANYACCESSORIES.GENERAL NOTES - MECHANICAL DEMOREVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00MD-101FIRST FLOORMECHANICALDEMOLITION PLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"1MECHANICAL DEMOLITION FIRST FLOOR 1234567EDCBAFREMOVE EXISTING FURNACEREMOVE EXISTING MAGIC PAKAHU AT ATTIC ABOVE, REMOVEASSOCIATED DUCTWORK AT 2NDFLOOR CEILINGREMOVE EXISTING FAN AT WALLREMOVE EXISTING UNIT HEATERAND ALL ASSOCIATED HOTWATER PIPING1)REFER TO DRAWING M-500 FOR EQUIPMENT SCHEDULE AND DRAWING M-500 FOR EQUIPMENTSYMBOLS, LEGENDS, AND ABBREVIATIONS.2)REMOVE ALL EXISTING MECHANICAL HEATING AND COOLING SYSTEMS, INCLUDING BUT NOTLIMITED TO ALL ASSOCIATED FLUES, PIPING, VALVES, THERMOSTATS, WIRING AND ANYACCESSORIES.GENERAL NOTES - MECHANICAL DEMOREVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00MD-102SECOND FLOORMECHANICALDEMOLITION PLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"1MECHANICAL DEMOLITION 2ND FLOOR TEMPERATURE CONTROL LEGENDPIPING LEGENDHVAC DUCTWORK LEGENDHVAC DEMOLITION LEGENDMECHANICAL ABBREVIATION LISTPIPE RISEUNIONPIPE DROPCHECK VALVEGLOBE VALVERETURN/EXHAUST/OUTSIDE AIR ARROWOPEN ENDED DUCT WITH 1/2" SQUARERETURN/EXHAUST REGISTERGALVANIZED STEEL WIRE MESH SCREEN.UNDERCUT DOORSUPPLY DIFFUSER (ARROWS DESIGNATEPATTERN REQUIREMENTS)SUPPLY ARROWUDCDBALL VALVEGATE VALVECONDENSATE DRAINREFSYMBOLREFRIGERANT LIQUIDDESCRIPTIONNEW DUCTWORK (SINGLE LINE)VOLUME DAMPERMOTORIZED DAMPERFIRE DAMPER WITH ACCESS DOORBACKDRAFT DAMPERRETURN DUCT DROP (SINGLE LINE)RETURN DUCT RISE (SINGLE LINE)RETURN DUCT RISE (DOUBLE LINE)SUPPLY DUCT DROP (SINGLE LINE)SUPPLY DUCT DROP (DOUBLE LINE)SUPPLY DUCT RISE (SINGLE LINE)SUPPLY DUCT RISE (DOUBLE LINE)RETURN DUCT DROP (DOUBLE LINE)MDBDFD/ADTHERMOSTATEXISTING DUCTWORK (DOUBLE LINE)FLEXIBLE DUCTWORKNEW DUCTWORK (DOUBLE LINE)ACOUSTICAL LINED DUCTWORKEXISTING DUCTWORK (SINGLE LINE)(DOUBLE LINED)ACOUSTICAL LINED DUCTWORK(SINGLE LINED)SYMBOL DESCRIPTIONDESCRIPTIONHWSSYMBOLREREMOVE EXISTING DUCTWORK/EQUIPMENTREMOVE EXISTING PIPING/EQUIPMENTREMOVE EXISTINGHOT WATER SUPPLYHOT WATER RETURNHWSHWRABBREVIATION DESCRIPTIONAIR COND. UNITACCESS DOORABOVE FINISHED FLOORAMBIENTAPPROXIMATEAVERAGEBREAK HORSE POWERBRITISH THERMAL UNITCAPACITYCUBIC FEET PER MINUTECUBIC FOOTDRY BULBENTERING AIR TEMPERATUREEXHAUST FANENTERINGEXTERNAL STATIC PRESSUREENTERING WATER TEMPERATUREEXISTINGEXHAUSTEXTERNALDEGREES FAHRENHEITFIRE DAMPERFEET PER MINUTEFEETGAUGEGALLONGALLONS PER MINUTEHEADHORSE POWERHOURFREQUENCYINCHINCHES WATER GAUGEKILOWATTLEAVING AIR TEMPERATUREPOUNDSLINEAR FEETLEAVINGLEAVING WATER TEMPERATUREBTU PER HOUR (THOUSAND)MINIMUMNOT TO SCALENOT APPLICABLENOISE CRITERIANOT IN CONTRACTOUTSIDE AIRPRESSURE DROP (FEET OF WATER OR INCHES OF WATER)PHASEPRESSUREPOUNDS PER SQUARE INCH GAUGERETURN AIRREVOLUTIONS PER MINUTESUPPLY AIRSTATIC PRESSURESQUARE FEETTYPICALVOLUME DAMPERVELOCITYVOLUMEWET BULBAC-#ADAFFAMBAPPROXAVGBHPBTUCAPCFMCU FTDBEATEF-#ENTESPEWTEXGEXHEXT°FFDFPMFTGAGALGPMHDHPHRHZIN.IN.W.GKWLATLBSLFLWTMBHMINN.T.S.N/ANCNICOAPDPHPRESSPSIGRARPMSASPSQ.FT.TYPVDVELVOLWBCONDENSATE DRAINCDHWR HOT WATER RETURNHWS HOT WATER SUPPLYEXISTING TO REMAINETREXISTING TO REMAINETSYMBOLS DESCRIPTIONREVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00M-000MECHANICALABBREVIATIONS NOTES& SYMBOLSISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA J1234567EDCBAF720 CFMB32"x12"320 CFMA14"x6"150 CFMA12"x6"150 CFMA12"x6"150 CFMA12"x6"150 CFMA12"x6"24"x8"VRV-1-1VRV-1-212"x8"TTREFRIGERANTPIPING UP TO 2NDFLOOR1-1/4" HWS&R UPTO BOILERS AT2ND FLOORTTTTTTO HOT WATERUNIT HEATER UH-3T6" OUTDOOR AIRINTAKE DUCT,BALANCE FOR 100CFM, TERMINATEAT ROOF CAP6" OUTDOORAIR INTAKEDUCT, BALANCEFOR 100 CFMSHOWER104RESTROOM102STORAGE/WORKROOM103STAIRS2STAIRS1JANITOR'S CLOSET100BSHELLFISHPROPAGATION AREA100STORAGE CLOSETS100ASPAWN ROOMS10149.43 SF4'-0"R20.5 GPMCUH-1UH-1UH-2UH-3100 CFMA12"x6"100 CFMA12"x6"100 CFMA12"x6"100 CFMA12"x6"450 CFMB12"x12"EF-2UH-4TO VRV-1-2EF-175 CFMC8"x4"75 CFMD8"x4"12"x6"24"x8"12"x8"TDN THRU FLOORTERMINATE WITH 1/2" WIREMESH SCREEN14"x26"VRV-1-34" OUTDOOR AIRINTAKE DUCT,BALANCE FOR70 CFMUP TO SECOND FLOOR4'-0"R20.5 GPM4'-0"R20.5 GPM4'-0"R20.5 GPM4'-0"R20.5 GPM4'-0"R20.5 GPM1 1/4"ø HWR1 1/4"ø HWS3/4"ø HWR3/4"ø HWS3/4"ø HWS3/4"ø HWR3/4"ø HWR3/4"ø HWS3/4"ø HWR3/4"ø HWS3/4"ø HWS3/4"ø HWR1"ø HWR1"ø HWS3/4"ø HWR3/4"ø HWS3/4"ø HWR3/4"ø HWS3/4"ø HWR3/4"ø HWSLOW ONWALLLOW ONWALL1"ø HWR1"ø HWS3/4"ø HWR3/4"ø HWSCU-1PROVIDE DUCT TO REDIRECTCONDENSER AIR EXHAUST 90 DEGREES,ADHERE TO MANUFACTURERSREQUIREMENTS FOR SMALL SPACEINSTALLATION.1"ø HWS3/4"ø HWRUP TO SECOND FLOOR1"ø HWRUP TOSECONDFLOOR3/4"ø HWSUP TOSECONDFLOOR46"x12"TOILET EXHAUSTTO TERMINATE ATROOF CAP8"x4"12"x4"8"x4"12"x4"345 CFMA12"x8"10"x8"TOILET EXHAUSTDUCT TOTERMINATE ATROOF CAP1"ø COND3/4"ø COND3/4"ø COND3/4"ø COND100 CFMA12"x6"TO VRV-1-1TO VRV-1-3UH-7T3/4"ø HWR3/4"ø HWS3/4"ø HWS3/4"ø HWR1"ø HWS1"ø HWR32"x12"1)REFER TO DRAWING M-500 FOR EQUIPMENT SCHEDULE AND DRAWING M-500 FOR EQUIPMENTSYMBOLS, LEGENDS, AND ABBREVIATIONS.2)PROVIDE FIRE STOPPING AND SMOKE BARRIER SEALING OF ALL PENETRATIONS THROUGH FIREWALLS OR SMOKE BARRIERS AS REQUIRED. REFER TO ARCHITECTURAL FLOOR PLANS ANDCODE SHEETS FOR WALLS.GENERAL NOTES - MECHANICAL3)PROVIDE MOTORIZED CONTROL VALVE AT ALL HEATING TERMINAL UNITS, INCLUDING BUT NOTLIMITED TO FIN TUBE RATIATION, CABINET UNIT HEATERS, UNIT HEATERS AND CEILING MOUNTEDUNIT HEATERS.4)PROVIDE VOLUME DAMPERS AT ALL BRANCH DUCTS.5)SEQUENCE OF OPERATIONS:COOLING: UPON RISE IN ROOM TEMPERATURE (74 DEGREES F ADJUSTABLE), THE VRV SERVINGTHE SPACE SHALL MODULATE USING INTERNAL CONTROLS TO SATISFY THE COOLING DEMAND.HEATING: UPON DROP IN ROOM TEMPERATURE OF 0.5 DEGREES F BELOW THE EFFECTIVEHEATING SETPOINT (72 DEGREES F ADJUSTABLE), PERIMETER HYDRONIC RADIATION SHALL BEENERGIZED (EACH RADIATOR SHALL HAVE A MOTORIZED VALVE AS STATED ABOVE). UPONFURTHER DROP IN ROOM TEMPERATURE OF 1.8 DEGREES F BELOW THE EFFECTIVE HEATING ETPOINT (70 DEGREES F ADJUSTABLE), THE VRV SERVING THE SPACE SHALL MODULATE USINGINTERNAL CONTROLS TO SATISFY THE HEATING DEMAND.REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00M-101FIRST FLOORMECHANICAL PLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"1MECHANICAL DUCTWORK FIRST FLOOR JJJJ1234567EDCBAFVRV-2-2VRV-2-3VRV-2-1OUTDOOR AIRINTAKEB-2HWP-2EXHAUST AIRDISHCARGE10"ø8"ø10"ø8"ø8"ø8"ø4"ø4"øCOMBUSTION AIRINTAKE (TYP FOR2) TERMINATE ATWALL CAPTTT100 CFMA8"x8"50 CFMD8"x8"50 CFMD8"x8"100 CFMA8"x8"100 CFMA8"x8"50 CFMD8"x8"REFRIGERANTSUCTION ANDLIQUID PIPING(TYP)UH-6OFFICE201OFFICE202TANK HEATEREQUIP. ROOM203TANK SERVICEROOM204MECHANICAL205CORRIDOR200CLOSET201ARESTROOM206STAIRS1CLOSET202AEF-36" TX UP THRUROOF.TERMINATE ATROOF CAP.EF-4MAF-1SOFFIT VENT SEEARCHITECT'SDRAWINGS FORLOCATION,DIMENSIONS ANDDETAIL(TYP)UH-5B-1BP-2BP-1HWP-1HWC-15'-6"R10.5 GPM23'-0"R11.3 GPM20'-6"R11.2 GPM3/4"ø HWR3/4"ø HWS3/4"ø HWR3/4"ø HWS3/4"ø HWS3/4"ø HWR1 1/4"ø HWR1"ø HWR1"ø HWS4"ø3/4"ø HWS3/4"ø HWR3/4"ø HWS3/4"ø HWRET-1AS-11 1/4"ø HWR1 1/4"ø HWSDN TO FIRST FLDN TO FIRST FLTMAKE UP AIR DUCT DNTO FIRST FLOOR26"x14"INSTALLED VERTICALLYAT SIDEWALLWITH FAN GUARDAND GRAVITYBACKDRAFTDAMPERTERMINATE WITH 1/2"WIRE MESH SCREEN3/4"ø HWR1"ø HWR1"ø HWS3/4"ø HWSDN TO FIRST FLDN TO FIRST FLEQUIPMENT BYOTHERS8"ø8"ø8"øERV-13/4"ø HWS3/4"ø HWR3/4"ø COND3/4"ø COND3/4"ø COND8"x8"8"x8"1 1/4"ø HWSTTHERMOSTATSHALL BE TIED TOOPERATION OFEF-4, SEEDRAWING EP-102KEY NOTE "E4".MITSUBISHI DIAMONDCONTROLLER DC-1 ANDPOWER SUPPLY MODULEDC1-PSTERMINATE ATWALL CAPTERMINATE ATWALL CAP2455 CFMA26"x14"FLUE UP TO TERMINAT AT ROOFFLUE UP TO TERMINAT AT ROOF4"ø1)REFER TO DRAWING M-500 FOR EQUIPMENT SCHEDULE AND DRAWING M-500 FOR EQUIPMENTSYMBOLS, LEGENDS, AND ABBREVIATIONS.2)PROVIDE FIRE STOPPING AND SMOKE BARRIER SEALING OF ALL PENETRATIONS THROUGH FIREWALLS OR SMOKE BARRIERS AS REQUIRED. REFER TO ARCHITECTURAL FLOOR PLANS ANDCODE SHEETS FOR WALLS.GENERAL NOTES - MECHANICAL3)PROVIDE MOTORIZED CONTROL VALVE AT ALL HEATING TERMINAL UNITS, INCLUDING BUT NOTLIMITED TO FIN TUBE RATIATION, CABINET UNIT HEATERS, UNIT HEATERS AND CEILING MOUNTEDUNIT HEATERS.4)PROVIDE VOLUME DAMPERS AT ALL BRANCH DUCTS.5)SEQUENCE OF OPERATIONS:COOLING: UPON RISE IN ROOM TEMPERATURE (74 DEGREES F ADJUSTABLE), THE VRV SERVINGTHE SPACE SHALL MODULATE USING INTERNAL CONTROLS TO SATISFY THE COOLING DEMAND.HEATING: UPON DROP IN ROOM TEMPERATURE OF 0.5 DEGREES F BELOW THE EFFECTIVEHEATING SETPOINT (72 DEGREES F ADJUSTABLE), PERIMETER HYDRONIC RADIATION SHALL BEENERGIZED (EACH RADIATOR SHALL HAVE A MOTORIZED VALVE AS STATED ABOVE). UPONFURTHER DROP IN ROOM TEMPERATURE OF 1.8 DEGREES F BELOW THE EFFECTIVE HEATING ETPOINT (70 DEGREES F ADJUSTABLE), THE VRV SERVING THE SPACE SHALL MODULATE USINGINTERNAL CONTROLS TO SATISFY THE HEATING DEMAND.REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00M-102SECOND FLOORMECHANICAL PLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"1MECHANICAL DUCTWORK 2ND FLOOR 2" HWSHWP-1HWP-22" HWS2" HWS2" HWS2" HWSAS-1B-12" HWS2"HWRMDPHWSHWRLOCATED ATUH-2B-22" HWS2" HWSM2" HWRTEMPERATUREANDPRESSURETESTCONNECTION(TYP.)2" HWS2" HWR2" HWRWALL MOUNTEDWALL MOUNTEDBP-1BP-2DOMESTIC COLD WATER MAKE-UPBALANCE VALVE1" HWSTHERMOMETER(TYPICAL)MOTORIZED VALVE(TYPICAL)TEMPERATURE SENSOR (TYPICAL)ET-1SEE DETAIL THISSHEET FOR PUMPDETAIL (TYP)1-1/4" HWS24" MIN3/4" DRAINVALVE3/4" DRAINVALVECONDENSATESEE M8.02DETAIL #12.CONDENSATESEE M8.02DETAIL #12.SEE DETAIL THISSHEET FOR PUMPDETAIL (TYP)SEE DETAIL THISSHEET FOR PUMPDETAIL (TYP)HWSHWRUP TO 7.0 GPMOATEMPSENSORN.T.S.HOT WATER RETURNHOT WATER SUPPLYBALANCE VALVEREDUCER (TYPICAL)AQUASTATCONTROL VALVESTRAINERBALL VALVE (TYPICAL)HOT WATER COILCABINET ENCLOSUREFAN BOARD ASSEMBLYDRAIN VALVE WITH 3/4"HOSE END CONNECTIONAND BRASS PLUGUNION(TYPICAL)LONG RADIUS TEE1/4W, 4"MIN.SUPPLY AND RETURN DUCTSTYPICAL TURNING VANED+D1SUPPLY DUCTS ONLYLONG RADIUS TEED+D1D1DAIRFLOWDSUPPLY DUCTS ONLYTAKE-OFFSUPPLY DUCTS ONLYTAKE-OFF45°1/4W, 4"MIN.AIRFLOWDDWSLOPE 1" IN 7"SUPPLY AND RETURN DUCTSFULL RADIUS ELBOWAIRFLOWD1W1-1/2WRETURN DUCTS ONLY1-1/2WAIRFLOWWSLOPE 1" IN 7"RETURN DUCTS ONLYTAKE-OFFAIRFLOWW45°1"1"SQUARE ELBOWSUPPLY AND RETURN DUCTS1"R2"R1"1"90°D>D1D1>4"N.T.S.DOUBLE THICKNESSTURNING VANESN.T.S.HANGER ROD, SECURE TO STRUCTURE ABOVE.SIZE IN ACCORDANCE WITH MANUFACTURER'SRECOMMENDATIONS. PUMP TO BE SUPPORTEDSEPERATELY FROM PIPING.STRAINERFLOWCHECK VALVEBALL VALVE (TYPICAL)BALANCING VALVEPRESSURE GAUGEIN-LINE PUMPAIR FLOWREDUCER (TYPICAL)UNIT HEATERBALANCE VALVEAQUASTATSTRAINERUNION (TYPICAL)N.T.S.MANUAL AIR VENT SEEDETAIL (TYPICAL)DRAIN VALVE WITH 3/4" HOSEEND CONNECTION AND BRASSPLUGBALL VALVE (TYPICAL)CONTROL VALVEHOT WATER RETURNHOTWATERSUPPLYREDUCER (TYPICAL)N.T.S.BALANCE VALVEHOT WATER SUPPLYPARTITION WALL ORCHASEHOT WATER RETURNCONTROL VALVEBALL VALVE WITHCAPPED HOSE ENDEXTRUDED ALUMINUM GRILLE0.0 GPM - 3.0 GPM, 3/4"3.5 GPM - 7.0 GPM, 1"COILFLEXIBLE CONNECTORS AND DOUBLEELBOWS NOT REQUIRED FOR DUCTMOUNTED COILHWC-1TWO WAY CONTROL VALVE, TWOPOSITIONN.T.S.1HEATING SYSTEM HYDRONIC PIPING DIAGRAM4HOT WATER CABINET UNIT HEATER PIPING DIAGRAMN.T.S.5TYPICAL DUCT DETAILS3IN-LINE PUMP DETAIL6HORIZONTAL HOT WATER UNIT HEATER PIPING DIAGRAMHOT WATER FIN TUBE RADIATION PIPING DIAGRAM27HOT WATER COIL PIPING DIAGRAMNOTES:A.JJM CONDENSATE NEUTRALIZING TUBEB.FACTORY SUPPLIED CONDENSATE TRAP. PROVIDE FIELD FABRICATED SUPPORTS AS REQUIRED.C.CONDENSATE DRAIN TERMINATION AT FLOOR DRAIN OR CONDENSATE PUMP RESERVOIR INLET. SECURE IN PLACE AS REQUIRED.D.FLOOR DRAIN OR SUMP.E.BOTTOM OF BOILER CONDENSATE OUTLET MUST BE ABOVE THE THE BOTTOM OF THE JM TUBE CONDENSATE OUTLET.F.UNISTRUT CLAMPS, SECURE TUBE IN POSITION AND SECURELY. CONDENSATE OUTLET MUST BE ORIENTED UP, WITH CONDENSATE INLETTO THE SIDE.G.UNISTRUT BASE, BOLT TO FLOOR OR MOUNTING PAD.H.PLASTIC TUBING OR PVC PIPE.I.USE HOSE CLAMPS AT ALL CONNECTIONS WHEN USING FACTORY SUPPLIED RUBBER HOSE.WALL MOUNTEDCONDENSING BOILERBEADFLOORHHICGFBOILERVENTWALLREVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00M-201MECHANICAL DETAILSISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MANTS8BOILER CONDENSATE TUBE DETAIL -SHELLFISH PROP100204TANK SERVICESHELLFISH PROP100SHELLFISH PROP100205MECHANICALSTAIRS2(FPM)SHOWER1043. PROVIDE WITH VIBRATION ISOLATORS.4. PROVIDE WITH 12" HIGH ROOF CURB.2. PROVIDE WITH GRAVITY BACKDRAFT DAMPER.1. PROVIDE WITH DISCONNECT SWITCH.RMUBF = ROOF MOUNTED UPBLAST FANRMDBF = ROOF MOUNTED DOWNBLAST FANIL = IN-LINETYPE:REMARKS:CEF = CEILING EXHAUST FANDRIVE:B = BELT DRIVED = DIRECT DRIVECB = CENTRIFUGAL BLOWERMANUFACTURER/MODEL NUMBERSYMBOL TYPE LOCATION SERVINGSP(IN WG)FANSPEED(RPM)DRIVE BHPAIRFLOW(CFM)HP VOLTS PHMOTOR DATAWEIGHT(LBS)SONES REMARKS1. CENTER DIFFUSERS, GRILLES & REGISTERS INSTALLED IN CEILINGS IN ONE HALF OF 2'x4' CEILING TILESOR CENTERED IN 2'x2' CEILING TILES. REFER TO ARCHITECT'S REFLECTED CEILING PLAN.MODEL NUMBER880KREUGERMANUFACTURER/BSYMBOLASUPPLYDUTY TYPENECK VEL.MAXIMUM(FPM)400CONSTRUCTION<16 STEELFRAMESURFACE MOUNTED WITH SCREWED FLANGEBLADESREMARKSCRITERIANOISESTEELSIDEWALLGRILLETACOMODEL NUMBERMANUFACTURER/C = COMPRESSIONTYPES:ET-1SYMBOLMIN. ACCEPTANCEVOLUME (GAL)MECH ROOMCONFIGURATION:V = VERTICALH = HORIZONTALCA90-125D/HTYPE/SYSTEMVOLUME (GAL)10MIN.TANK205LOCATIONSIZE(DIA x L)D = DIAPHRAGM30x20BELL & GOSSETTMODEL NUMBERMANUFACTURER/AS-1SYMBOLMECH ROOMROLAIRTROL RL-2 205LOCATIONHHWSCONFIGURATION3.5NOTESNOTES:1.HHWSSERVICE20FLOW (GPM)1.0(FT. WATER)PRESSURE DROPINPUTVITODENS WB2B-26MANUFACTURER/MODEL NUMBERSYMBOLB-1VIESSMANN(MBH)ELECTRICAL DATAAMPS12.00.87CONTENTWATER1PHASEVOLTS120WEIGHT(LBS)102OPERATINGMEDIAHW(GALS)FUEL DATANG(MBH)IBR RATETYPE1. OUTPUT RATING BASED ON 160°F/120°F SUPPLY/RETURN.REMARKS:9.5/4.34" MIN.(IN. WG)PRESSURE2. BOILERS SHALL BE ELECTRONIC IGNITION.7431-93FLOW/MAXIMUMFLOW3. BOILERS SHALL BE PROVIDED WITH TEMPERATURE SENSOR, AND(MBH)28-85OUTPUTVITOCONTROL-S WB2B FOR USE IN MULTIPLE BOILER APPLICATIONS.(FT)7.5WPD96.1%EFFICIENCYDIMENSIONS(W x H x D)17.75x33.5x14MEDIA:HW = HOT WATERRET/EXHCEILING RETURN500STEEL STEELS80KREUGERGRILLE<16SURFACE MOUNTED WITH SCREWED FLANGEMANUFACTURER/MODEL NUMBERSYMBOL TYPELOCATIONELECTRICALVOLTS PHASEHPCAPACITY(MBH)(MIN/MAX)FLOWAIR H.W.FLOW(GPM)DIMENSIONAMPSW.T.ENT LVGW.T.(°F) (°F)NO.OFROWS2. PROVIDE WITH THERMOSTAT.NOTES:1. PROVIDE WITH ADJUSTABLE HORIZONTAL & VERTICAL BLADES.4. PROVIDE VIBRATION ISOLATION AND HANGING RODS.3. PROVIDE WITH OPTIONAL RECESSED INSTALLATION KIT.REMARKS(WxDxH)1CUH-1RITTLINGWALLMTDVESTIBULE 1011201/6010.3516012012BHP(GPM)PHASEVOLTSRPMHPMOTOR DATA(%)(°F)EFFPUMP(FT)TDHRATE TEMPAVG. FLUIDMEDIALOCATIONTYPESYMBOLHWP-1MANUFACTURER/MODEL NUMBERIL = IN-LINEREMARKS:BM = BASE MOUNTED1. PUMP SHALL BE PROVIDED WITH INTEGRAL ECM MOTOR TO ALLOW FOR VARIABLE SPEED OPERATION.FLOWREMARKSHWP-2WATER12081/4- 1600-48002520 140HEATING205MECH ROOMIL681.25x3-30WILO STRATOS1ILWATER12081/4- 1600-48002520 140HEATING205MECH ROOMIL68138.2x10x24RW-260-02EF-11,2,3D -8150.251501ST FL TOILET/JANITOR1ST FLTOILETILLOREN COOKGN-186N/A 120 1 18 2.5CDFBKREUGER0.76.9150CEILING EXHAUST500DS80KREUGERRETURNSTEEL STEEL<16GRILLELAY-IN T-BAR, 1" FILTER4. PROVIDE VERTICAL VENT (COAXIAL) COMBINED FLUE AND COMBUSTION AIRINTAKE.WILO STRATOS1.25x3-305. PROVIDE WITH OUTDOOR AIR RESET AND MODULATING CONTROL.UH-1RITTLINGRH-6319.91/1012011.0870MTDCLG2,41.325.8x13.3x19VITODENS WB2B-26B-2VIESSMANNHWSOUNDPRESSURE(BTUH)CAPACITIESCOOLING HEATING(BTUH)TONSNOMINALSYMBOLREMARKSMCAVOLTS PHASEELECTRICAL(LBS)WEIGHTUNITS SERVEDMANUFACTURER MODEL LOCATIONMITSUBISHIVRV-1-1, VRV-1-2, VRV-1-3, VRV-2-1,VRV-2-2 & VRV-2-360135,000120,000101,2.3,4,5,645 208 3 697PUHY-P120TKMU-BS 1ST FL(dBA)REMARKS:1. R410A REFRIGERANT. CAPACITY RATINGS AT ARI CONDITIONS. COOLING - 80°F EDB, 67°F EWB, 95°F ODB. HEATING - 70°F EDB, 47°F ODB, 43°F OWB.2. DIVISION 26 TO PROVIDE DISCONNECT PER "a" MODULE, "b" MODULE AND "c" MODULE3. PROVIDE WITH DUCT COWL ON TOP OF UNIT TO DISCHARGE 90 DEGREES.4. PROVIDE WITH DC-600E DIAMOND CONTROLLER, NPB-BATTERY/U OPTIONAL BATTERY KIT, NPB-PWR-UN-H/U OPTIONAL 90-263 VOLT AC POWER SUPPLYMODULE, NPM-256MB/U UPGRADE RAM MEMORY TO 256 MB.5. PROVIDE MITSUBISHI MODEL AE-200A CENTRALIZED CONTROLLER, UNIT SHALL INCLUDE MONITORING ANNUAL AND WEEKLY SCHEDULING, SENDINGERROR EMAIL, ONLINE MAINTENANCE TOOL, INTERLOCK CONTROL AND DATA MONITORING.6. REFRIGERANT PIPE SIZES AND QUANTITIES SHALL BE GOVERNED BY FINAL FIELD LAYOUT.CU-1(MBH)HEATINGCOOLINGCAPACITIES(MBH)REMARKSTYPEMODELMANUFACTURERSYMBOLNOM.TONSFANPHASEVOLTSMCAELECTRICALSOUNDREFRIGERANT PIPING FROMCONDENSING UNIT TO AIRHANDLERLIQUID GASLOCATIONCFM(LOW-HIGH)1ST FLOOR(dBA)VRF-1-1DMITSUBISHI(HIGH)1.5 600 17.6/13.6 9.9 1/4" 1/2" 1.56PEFY-P18NMAU-E3208 1 - -WATTS66EF-21,2,3D -7720.275SHOWER 104SHOWER104ILLOREN COOKGC-146N/A 120 1 17 0.930EF-31,2,3D -7720.275RESTROOM206RESTROOM206ILLOREN COOKGC-146N/A 120 1 17 0.930BOILERPUMPBP-1BP-20.87 102NG9.5/4.34" MIN.7431-93 28-857.596.1%17.75x33.5x14 12.0 1120BP-1IL11150.14- 1300-2700219.5 140205MECH ROOMIL-1WILO STAR S21 FXWATERHEATINGBP-2IL11150.14- 1300-2700219.5 140205MECH ROOMIL-1WILO STAR S21 FXWATERHEATINGUH-2RITTLINGRH-63MTDCLG2,4UH-3RITTLINGRH-63MTDCLG2,41UH-5RH-249.01/3012010.5450MTD2,40.7016.9x12x15RITTLINGCLG1UH-6RH-247.41/3012010.5350MTD2,40.70RITTLINGCLGTC/SC1ST FLOORVRF-1-2DPEFY-P36NMAU-E3MITSUBISHI3.0 1165 35.8/27.9 20.1 3/8" 5/8" 3.5 208 1 - -SPAWN ROOM S10VRF-1-3CPCFY-P15NKMU-EMITSUBISHI1.5 460 14.7/9.9 8.5 1/4" 1/2" 0.44 208 1 - -OFFICE 201VRF-2-1BPKFY-P24NKMU-E2MITSUBISHI2.0 915 23.8/19.5 15.1 3/8" 5/8" 0.63 208 1 - -TANK SERVICE ROOMVRF-2-2BPKFY-P12NHMU-E2MITSUBISHI1.0 415 11.7/8.7 7.53/8" 5/8"0.38 208 1 - -OFFICE 202VRF-2-3BPKFY-P24NHMU-E2MITSUBISHI2.0 915 23.8/19.5 15.11/4" 1/2"0.63 208 1 - -EF-41,3,5D -10800.16200TANK ROOM203TANK ROOM 203PWFLOREN COOK24XW32D1023/4120 164 14.3N/APWF = PROPELLER WALL FANMAF-11,2,3B -17251.52455TANK ROOM203TANK ROOM 203CBLOREN COOK165 CPV1.5208 3368 69 dBAN/A119.91/1012011.08701.325.8x13.3x19119.91/1012011.08701.325.8x13.3x1916.9x12x15UH-4BEACON MORRISTWIN FLOW III W42WALLREC3.5551.011/300.5 120125x4x163PERFORMANCE - GENERAL(IN WG)CFMAPDEXHAUST AIR(IN WG)APDSUPPLY AIR ENTHALPY RECOVWINTER(%)SUMMER(%)EFFECTIVENESSSUMMER (%)WINTER (%)DIMENSIONSEFFECTIVENESSCFM0.750.75 63 5063 65.530012-3/8"x40"x34-15-16"300UNITMANUFACTURERMODEL NO.ERV-1MITSUBISHILOSSNAYREMARKS:UNITLOCATIONREMARKS1,2,3(HxWxD)VOLTS PHASE1.7 208 1ELECTRICALESP0.78(IN. WC)MCA1. PROVIDE WITH OPTIONAL MOTORIZED DAMPERS ON EXHAUST AIR AND OUTSIDE AIR CONNECTIONS, FACTORY WIRED.MECH RM2052. PROVIDE WITH FUSED DISCONNECT, DOUBLE WALL CONSTRUCTION, FACTORY MOUNTED FILTER ALARMS(2), BACKDRAFT DAMPERS AT OA AND EXHAUST AIR.3. PROVIDE WITH SC-ECM - REMOTE POTENTIOMETER SPEED CONTROL.LGH-F300RX5-EWEIGHT(LBS)7316012016012016012016012016012016012072AIR SIDEMODEL NUMBERMANUFACTURER/HWC-1SYMBOLCARNESAVW 10DMTYPE2OF19.920TOTALCAPEAT(°F)1.0FLOWWATER SIDE0.039PD(IN WG)LAT(°F)120160LWTEWT0.17(GPM)PD(FT HD)1REMARKS(MBH)340VELOCITYMAXIMUMFACEFL300(CFM)FLOWNO.ROWS(°F)(°F)(W x H)SIZE12X14SI = SLIP-IN CONNECTIONSFL = FLANGED CONNECTIONSDM = DUCT MOUNTEDTYPES:1. PROVIDE DUCT MOUNTED COILS WITH INTEGRAL STAINLESS STEEL DRAIN PAN.REMARKS:2. PROVIDE TEMPERTURE SENSOR ADJACENT TO HOT WATER COILRET/EXHSIDEWALL RETURN500STEEL STEELGRILLE<16SURFACE MOUNTED WITH SCREWED FLANGEUH-7BEACON MORRISTWIN FLOW III W42WALLREC3.5551.011/300.5120125x4x1631601205. PROVIDE WITH BELT GUARD.NOTE:INDICATES UNIT TYPEINDICATES NECK SIZE ORLENGTH(LINEAR ONLY)INDICATES UNITCFM CAPACITYA12x12400REMARKS:OF FIN TUBEINDICATES TYPEACTIVE FINNED ELEMENTINDICATES LENGTH OFCOPPERRITTLINGMANUFACTURER/MODEL NUMBERR1SYMBOLREMARKS568EWT160MOUNTINGHEIGHT TO4"PIPESIZE3/4"SIZEFINBTUH/LFCAPACITY(°F)8-7/8"HEIGHTENCLOSURETIERS1NO. OFBOTTOMLWT(°F)120FLOWGPM/LF- 1, 2 & 3INDICATES HEATING H.W.FLOW (GAL. PER MINUTE)1. PROVIDE SUPPORT SADDLE FOR RETURN PIPE AS REQUIRED.2. PROVIDE ALL REQUIRED MOUNTING HARDWARE AND ENCLOSURE ACCESS PANELS.3. FINISH TO BE CONFIRMED BY ARCHITECT.41_4" x 41_4" x 40RLENGTHGPMTYPE:A. CEILING RECESSED CASSETTE.B. HIGH WALL.C. CEILING SUSPENDED.D. DUCTED CONCEALED.REMARKS:1. COOLING CAPACITY AT 80°F EDB, 67°F EWB, & 95°F ODB. HEATING CAPACITY AT 70°F EDB, 47°F ODB & 43°F OWB.2. FURNISH AND INSTALL MANUFACTURES WIRED REMOTE TEMPERATURE SENSOR.3. FURNISH AND INSTALL ALL CONTROL WIRING NECESSARY FROM OUTDOOR UNIT, INDOOR UNIT, AND ALL OTHER CONTROLS ASSOCIATED WITH SYSTEM.4. PROVIDED WITH INTERNAL CONDENSATE PUMP.5. PROVIDE WITH RETURN AIR THERMISTOR.R23_4"C-41_4"x41_4"x40COPPERRITTLING3_4"C-41_4"x41_4"x48968 1604" 3/4"14-7/8"2120 - 1, 2 & 341_4" x 41_4" x 48EXHAUST/MAKE-UP AIR FAN SCHEDULEDIFFUSER AND REGISTER SCHEDULEEXPANSION TANK SCHEDULEAIR SEPARATOR SCHEDULEBOILER SCHEDULEUNIT HEATER/CABINET UNIT HEATER SCHEDULEPUMP SCHEDULEFINNED TUBE RADIATION SCHEDULEVRF OUTDOOR CONDENSING UNIT SCHEDULEVRF SYSTEM - INDOOR AIR HANDLER SCHEDULEENERGY RECOVERY VENTILATION UNIT SCHEDULEHOT WATER COIL SCHEDULEREVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00M-500MECHANICALSCHEDULESISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1234567EDCBAFTC TCEXISTING 2" UNDERGROUND ELECTRICSERVICE CONDUIT. REMOVE EXISTING120/240V-1PH-3W SERVICE CONDUCTORS.THE EC SHALL EVALUATE THE CONDITIONOF THE EXISTING CONDUIT TO DETERMINEIF REUSE IS POSSIBLE.EXISTING 120/240V-1PH-3WMETER SOCKET TO BEREMOVED.EXISTING PANELBOARD W/150A MCB MAIN SWITCH #1TO BE REMOVEDEXISTING TELEPHONE DISTRIBUTIONEQUIPMENT LOCATED ON UNDERSIDEOF FLOOR TO BE REMOVED.EXISTING PANELBOARDS W/150A MCB MAIN SWITCH #2TO BE REMOVED1)ALL ELECTRICAL DEVICES SHALL BE REMOVED UNLESS NOTED OTHERWISE. INCLUDING BUT NOTLIMITED TO RECEPTACLES, LIGHT FIXTURES, LIGHTING CONTROLS, FIRE ALARM DEVICES,MECHANICAL CONNECTIONS, ETC. REMOVAL SHALL BE COMPLETE INCLUDING BOXES,BRACKETS, HANGERS AND BRANCH CIRCUIT WIRING BACK TO SOURCE PANELBOARD OR LASTACTIVE DEVICE TO REMAIN.CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSAL OF ALL ITEMS TO BE REMOVED IN A SAFE,LEGAL AND RESPONSIBLE MANNER.CONTRACTOR SHALL BE RESPONSIBLE FOR STORAGE AND HANDLING OF EXISTING TO BERELOCATED EQUIPMENT.CONTRACTOR SHALL MODIFY EXISTING CIRCUITS, WHEN EXISTING DEVICES ARE REMOVED, ASREQUIRED TO MAINTAIN CIRCUIT CONTINUITY.THIS PLAN IS DIAGRAMMATIC AND NOT INTENDED TO DEPICT THE ENTIRE SCOPE OF ELECTRICALDEMOLITION. ADDITIONAL DEMOLITION AND MODIFICATION WORK NOT SHOWN SHOULD BEANTICIPATED.REFER TO DRAWING E-500 FOR ELECTRICAL SYMBOLS, LEGENDS AND ABBREVIATIONS.DEMOLITION NOTES - ELECTRICAL2)3)4)5)6)REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00ED-101FIRST FLOORELECTRICALDEMOLITION PLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"1FIRST FLOOR ELECTRICAL DEMOLITION PLAN 1234567EDCBAFTCEXISTING WIRELESS CCTVSYSTEM ANTENNA TO BEPRESERVED FOR REUSE.EXISTING CCTV CAMERAAND WP ENCLOSURE TO BEPRESERVED FOR REUSE.1)ALL ELECTRICAL DEVICES SHALL BE REMOVED UNLESS NOTED OTHERWISE. INCLUDING BUT NOTLIMITED TO RECEPTACLES, LIGHT FIXTURES, LIGHTING CONTROLS, FIRE ALARM DEVICES,MECHANICAL CONNECTIONS, ETC. REMOVAL SHALL BE COMPLETE INCLUDING BOXES,BRACKETS, HANGERS AND BRANCH CIRCUIT WIRING BACK TO SOURCE PANELBOARD OR LASTACTIVE DEVICE TO REMAIN.CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSAL OF ALL ITEMS TO BE REMOVED IN A SAFE,LEGAL AND RESPONSIBLE MANNER.CONTRACTOR SHALL BE RESPONSIBLE FOR STORAGE AND HANDLING OF EXISTING TO BERELOCATED EQUIPMENT.CONTRACTOR SHALL MODIFY EXISTING CIRCUITS, WHEN EXISTING DEVICES ARE REMOVED, ASREQUIRED TO MAINTAIN CIRCUIT CONTINUITY.THIS PLAN IS DIAGRAMMATIC AND NOT INTENDED TO DEPICT THE ENTIRE SCOPE OF ELECTRICALDEMOLITION. ADDITIONAL DEMOLITION AND MODIFICATION WORK NOT SHOWN SHOULD BEANTICIPATED.REFER TO DRAWING E-500 FOR ELECTRICAL SYMBOLS, LEGENDS AND ABBREVIATIONS.DEMOLITION NOTES - ELECTRICAL2)3)4)5)6)REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00ED-102SECOND FLOORELECTRICALDEMOLITION PLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"12ND FLOOR ELECTRICAL DEMOLITION PLAN 1234567EDCBAFAAAAWWAAAAAAAAAA1A1A1A3AA1AA1DAASHOWER104RESTROOM102STORAGE/WORKROOM103STAIRS2STAIRS1BROOD ROOM101JANITOR'S CLOSET100BSHELLFISHPROPAGATION AREA100STORAGE CLOSETS100AAA13343DDDOSOS3, P2A11, P2A1, P2AUP TOEL-102EM1EMEMEMEMEM1EMX1X1X1REMREMX1X2X21)ALL CIRCUITS SHALL BE 2#12,#12G.,3/4"C., TO NEW 20A-1P CIRCUIT BREAKER IN PANEL INDICATEDUNLESS NOTED OTHERWISE.ALL BRANCH CIRCUITS EXCEEDING 150' IN LENGTH SHALL BE 2#10,#10G., 3/4"C. UNLESS NOTEDOTHERWISE.ALL DEVICES SHALL BE LABELED WITH SOURCE PANEL AND CIRCUIT NUMBER(S).REFER TO ARCHITECTS REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING MOUNTEDELECTRICAL DEVICES.REFER TO DRAWING E-500 FOR LIGHTING FIXTURE SCHEDULE, ELECTRICAL SYMBOLS, LEGENDS,AND ABBREVIATIONS.EXIT SIGNS AND EMERGENCY LIGHTING FIXTURES SHALL BE WIRED TO LINE SIDE OF LOCALLIGHTING BRANCH CIRCUIT, AHEAD OF ALL SWITCHING DEVICES.2)GENERAL NOTES - ELECTRICAL LIGHTING3)4)5)6)REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00EL-101FIRST FLOORELECTRICAL LIGHTINGPLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"1FIRST FLOOR ELECTRICAL LIGHTING PLAN OSOSOSOS1234567EDCBAFB8B8A2B4B8B4WDOSA1A2OFFICE201OFFICE202TANK HEATEREQUIP. ROOM203TANK SERVICEROOM204MECHANICAL205CORRIDOR200CLOSET201ARESTROOM206STAIRS1CLOSET202AOSB4B4B4B4A1A2A17, P2ADN TOEL-101EMEMEMEMEMX1EM1)ALL CIRCUITS SHALL BE 2#12,#12G.,3/4"C., TO NEW 20A-1P CIRCUIT BREAKER IN PANEL INDICATEDUNLESS NOTED OTHERWISE.ALL BRANCH CIRCUITS EXCEEDING 150' IN LENGTH SHALL BE 2#10,#10G., 3/4"C. UNLESS NOTEDOTHERWISE.ALL DEVICES SHALL BE LABELED WITH SOURCE PANEL AND CIRCUIT NUMBER(S).REFER TO ARCHITECTS REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING MOUNTEDELECTRICAL DEVICES.REFER TO DRAWING E-500 FOR LIGHTING FIXTURE SCHEDULE, ELECTRICAL SYMBOLS, LEGENDS,AND ABBREVIATIONS.EXIT SIGNS AND EMERGENCY LIGHTING FIXTURES SHALL BE WIRED TO LINE SIDE OF LOCALLIGHTING BRANCH CIRCUIT, AHEAD OF ALL SWITCHING DEVICES.2)GENERAL NOTES - ELECTRICAL LIGHTING3)4)5)6)REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00EL-102SECOND FLOORELECTRICAL LIGHTINGPLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"12ND FLOOR ELECTRICAL LIGHTING PLAN JJJJJJJJJJJJFSSSSSFJJJJJJJ1234567EDCBAFGFIGFIGFIGFIGFIGFIGFISHOWER104RESTROOM102STORAGE/WORKROOM103STAIRS2STAIRS1BROOD ROOM101JANITOR'S CLOSET100BSHELLFISHPROPAGATION AREA100STORAGE CLOSETS100AGFIGFIGFIa,GFIGFIGFICUH-1VRV-1-3UH-1CU-1UH-3UH-4UH-2VRV-1-1VRV-1-2EF-1EF-234,36, P2A32, P2A15, P2A13, P2A31, P2A4, P2A43, P2A18, P2A2, P2A10, P2A12, P2ASP-1DCDCDCDCDCWP,GFIPUMP-16PUMP-23PUMP-3FACP38, P2A16, P2ASEEP1EP1EP1EP1EP2EP2EP219, P2ATELEPHONEDEMARC LOCATIONNEW UNDERGROUNDELECTRIC UTILITYTRENCH PER DETAILMETER SOCKET7 JAW RINGLESS240V-3PH-200AGROUND ROD PLACEDIN GROUND ENHANCINGBACKFILL SEE DETAILMAIN DISCONNECT SWITCH240V-3P-200AEP6EP3UH-7SECURITY SYSTEMPANELGFIGFIGFIGFI1)ALL CIRCUITS SHALL BE 2#12,#12G.,3/4"C., TO NEW 20A-1P CIRCUIT BREAKER IN PANEL INDICATEDUNLESS NOTED OTHERWISE.ALL BRANCH CIRCUITS EXCEEDING 150' IN LENGTH SHALL BE 2#10,#10G., 3/4"C. UNLESS NOTEDOTHERWISE.ALL DEVICES SHALL BE LABELED WITH SOURCE PANEL AND CIRCUIT NUMBER(S).REFER TO ARCHITECTS REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING MOUNTEDELECTRICAL DEVICES.REFER TO DRAWING E-500 FOR MOTOR CIRCUIT SCHEDULE, ELECTRICAL SYMBOLS, LEGENDS, ANDABBREVIATIONS.ALL RECEPTACLES LOCATED WITHIN 6' FROM SINKS SHALL BE GFCI TYPE.ALL RACEWAY, BACKBOXES, SWITCHBOXES, ETC SHALL BE PVC FOR SYSTEMS LOCATED IN THEPROPAGATION AREA AND ALSO WHERE EXPOSED.ALL RECEPTACLES LOCATED ON THE FIRST FLOOR SHALL BE PROVIDED WITH WEATHERPROOFWHILE IN USE COVERS.2)GENERAL NOTES - ELECTRICAL POWER3)4)5)7)8)6)ELECTRICAL POWER KEY NOTESEP1ALGAE GROWTH STATION POWER & LIGHTING CONTROL - THE EC SHALL PROVIDE A QUADRECEPTACLE AND LIGHTING CONTROL SWITCH AT EACH LOCATION INDICATED ON PLAN,MOUNTED AT 48" AFF.SEAWATER PUMP STATION POWER & CONTROL - THE EC SHALL PROVIDE A SINGLE POLEDISCONNECT SWITCH IN PVC BACKBOX WITH 3/4" LFMC WHIP CONNECTED TO THE PUMPMOTOR.SEWAGE EJECTOR PUMPING STATION CONTROL PANEL - THE SEWAGE EJECTOR CONTROLPANEL AT 208V-3PH SHALL BE WIRED COMPLETE BY THE EC. PROVIDE 3/4"C, 3#10 & #10G TOTHE CONTROL PANEL TERMINALS VIA A 240V-3P-30A NEMA 4X DISCONNECT SWITCH. PROVIDEALL CONNECTIONS WITH FLOAT ALARM CABLES PROVIDED WITH THE PUMP PACKAGE.PROVIDE A DEDICATED 3/4"C WITH 4#14 TO THE SECURITY PANEL FOR REMOTE MONITORINGOF ALARMS.TANK HEATER EQUIPMENT ROOM VENTILATION SYSTEM - THE EC SHALL PROVIDE MOTORSTARTER CONTROLS TO ENSURE SIMULTANEOUS OPERATION OF EF-4 & MAF-1 THROUGHINPUT OF A COOLING THERMOSTAT LOCATED IN THE EQUIPMENT ROOM. PROVIDE A 240V-3P-30A NEMA 4X FUSIBLE DISCONNECT SWITCH FOR EACH. PROVIDE A 20A FUSE FOR EF-4, 10AFUSES FOR MAF-1. PROVIDE ENCLOSED MOTOR STARTERS, NON-REVERSING WITH THERMALOVERLOAD, NEMA SIZE 0, 120V COIL. THERMOSTAT SHALL BE HONEYWELL #T651 MECHANICALTHERMOSTAT, MAKE ON A RISE, FOR LINE VOLTAGE APPLICATION.HEAT PUMP EQUIPMENT CONNECTIONS - THE EC SHALL PROVIDE A NEMA 4X FUSIBLE SWITCH240V-3P-30A WITH 10A FUSES IN 2 POLES. CONNECT TO THE EQUIPMENT WITH 3/4" LFMC, 2#12& #12G.PROVIDE SPIRAL WRAP HEAT TRACE CABLE ON THE SEWAGE EJECTOR PIT AND EXPOSEDDRAIN LINES. REFER TO THE PLUMBING DRAWINGS FOR EXACT ROUTING OF EXPOSED DRAINLINES. THE EC SHALL PROVIDE THE FOLLOWING:HEAT TRACE CABLE - 8W/FT RAYCHEM #8XL1-CRDIGITAL CONTROLLER - RAYCHEM #ECW-GFPOWER CONNECTION - RAYCHEM #PCINSULATION SHALL BE PROVIDED BY DIVISION 23.EP2EP3EP4EP5EP6REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00EP-101FIRST FLOORELECTRICAL POWERPLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"1FIRST FLOOR ELECTRICAL POWER PLAN JJJJJJJJJJJJJJJJJJJJSSSSSSFJHJ1234567EDCBAFP2Aa,GFIa,GFIa,GFIa,GFIa,GFIHWP-1HWP-2BP-2BP-1B-1B-2VRV-2-1VRV-2-2VRV-2-3UH-6EF-3MAF-1EF-4UH-5WH-1ERV-1OFFICE201OFFICE202TANK HEATEREQUIP. ROOM203TANK SERVICEROOM204MECHANICAL205CORRIDOR200CLOSET201ARESTROOM206STAIRS1CLOSET202A25,27, P2A40,42, P2A45,47, P2A39,41, P2A5, P2A28,30, P2A6, P2A8, P2A21, P2A26, P2A37, P2A14, P2A7, P2A33,35, P2A9, P2A24, P2A23, P2APUMP-4.2PUMP-4.4PUMP-4.3PUMP-4.1TWPEP5EP5EP5EP5EP429, P2A44,46,48, P2AWPREINSTALL EXISTINGWIRELESS CCTVCAMERA TRANSMITTERGFIGFIGFIGFIGFIELECTRICAL POWER KEY NOTESEP1ALGAE GROWTH STATION POWER & LIGHTING CONTROL - THE EC SHALL PROVIDE A QUADRECEPTACLE AND LIGHTING CONTROL SWITCH AT EACH LOCATION INDICATED ON PLAN,MOUNTED AT 48" AFF.SEAWATER PUMP STATION POWER & CONTROL - THE EC SHALL PROVIDE A SINGLE POLEDISCONNECT SWITCH IN PVC BACKBOX WITH 3/4" LFMC WHIP CONNECTED TO THE PUMPMOTOR.SEWAGE EJECTOR PUMPING STATION CONTROL PANEL - THE SEWAGE EJECTOR CONTROLPANEL AT 208V-3PH SHALL BE WIRED COMPLETE BY THE EC. PROVIDE 3/4"C, 3#10 & #10G TOTHE CONTROL PANEL TERMINALS VIA A 240V-3P-30A NEMA 4X DISCONNECT SWITCH. PROVIDEALL CONNECTIONS WITH FLOAT ALARM CABLES PROVIDED WITH THE PUMP PACKAGE.PROVIDE A DEDICATED 3/4"C WITH 4#14 TO THE SECURITY PANEL FOR REMOTE MONITORINGOF ALARMS.TANK HEATER EQUIPMENT ROOM VENTILATION SYSTEM - THE EC SHALL PROVIDE MOTORSTARTER CONTROLS TO ENSURE SIMULTANEOUS OPERATION OF EF-4 & MAF-1 THROUGHINPUT OF A COOLING THERMOSTAT LOCATED IN THE EQUIPMENT ROOM. PROVIDE A 240V-3P-30A NEMA 4X FUSIBLE DISCONNECT SWITCH FOR EACH. PROVIDE A 20A FUSE FOR EF-4, 10AFUSES FOR MAF-1. PROVIDE ENCLOSED MOTOR STARTERS, NON-REVERSING WITH THERMALOVERLOAD, NEMA SIZE 0, 120V COIL. THERMOSTAT SHALL BE HONEYWELL #T651 MECHANICALTHERMOSTAT, MAKE ON A RISE, FOR LINE VOLTAGE APPLICATION.HEAT PUMP EQUIPMENT CONNECTIONS - THE EC SHALL PROVIDE A NEMA 4X FUSIBLE SWITCH240V-3P-30A WITH 10A FUSES IN 2 POLES. CONNECT TO THE EQUIPMENT WITH 3/4" LFMC, 2#12& #12G.PROVIDE SPIRAL WRAP HEAT TRACE CABLE ON THE SEWAGE EJECTOR PIT AND EXPOSEDDRAIN LINES. REFER TO THE PLUMBING DRAWINGS FOR EXACT ROUTING OF EXPOSED DRAINLINES. THE EC SHALL PROVIDE THE FOLLOWING:HEAT TRACE CABLE - 8W/FT RAYCHEM #8XL1-CRDIGITAL CONTROLLER - RAYCHEM #ECW-GFPOWER CONNECTION - RAYCHEM #PCINSULATION SHALL BE PROVIDED BY DIVISION 23.EP2EP3EP4EP5EP61)ALL CIRCUITS SHALL BE 2#12,#12G.,3/4"C., TO NEW 20A-1P CIRCUIT BREAKER IN PANEL INDICATEDUNLESS NOTED OTHERWISE.ALL BRANCH CIRCUITS EXCEEDING 150' IN LENGTH SHALL BE 2#10,#10G., 3/4"C. UNLESS NOTEDOTHERWISE.ALL DEVICES SHALL BE LABELED WITH SOURCE PANEL AND CIRCUIT NUMBER(S).REFER TO ARCHITECTS REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING MOUNTEDELECTRICAL DEVICES.REFER TO DRAWING E-500 FOR MOTOR CIRCUIT SCHEDULE, ELECTRICAL SYMBOLS, LEGENDS, ANDABBREVIATIONS.ALL RECEPTACLES LOCATED WITHIN 6' FROM SINKS SHALL BE GFCI TYPE.ALL RACEWAY, BACKBOXES, SWITCHBOXES, ETC SHALL BE PVC FOR SYSTEMS LOCATED IN THEPROPAGATION AREA AND ALSO WHERE EXPOSED.ALL RECEPTACLES LOCATED ON THE FIRST FLOOR SHALL BE PROVIDED WITH WEATHERPROOFWHILE IN USE COVERS.2)GENERAL NOTES - ELECTRICAL POWER3)4)5)7)8)6)REVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00EP-102SECOND FLOORELECTRICAL POWERPLANISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA 1/4" = 1'-0"12ND FLOOR ELECTRICAL POWER PLAN JJSURFACE MOUNTED PANELBOARDDISCONNECT SWITCHMOTOR STARTERELECTRICAL MOTORELECTRICAL METERBRANCH CIRCUIT WIRING, CONCEALED IN WALLS OR CEILINGSHOMERUN TO PANELBOARD, UNLESS INDICATED OTHERWISE SHALL BECONNECTED TO A 1 POLE, 20 AMP CIRCUIT BREAKERBRANCH CIRCUIT WIRING, SWITCHEDCONDUIT RUN ON SURFACE OF WALLS/CEILINGBRANCH CIRCUIT WIRING BELOW GRADE/SLABJUNCTION BOXDUPLEX WALL MOUNTED RECEPTACLEDOUBLE DUPLEX WALL MOUNTED RECEPTACLEDUPLEX RECEPTACLE, MOUNT ABOVE COUNTER HEIGHTDUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTIONDUPLEX RECEPTACLE WITH WEATHERPROOF COVERDUPLEX RECEPTACLE WITH ISOLATED GROUNDSPECIAL PURPOSE CONNECTIONSPECIAL PURPOSE RECEPTACLE, NEMA CONFIGURATION AS INDICATEDSURFACE MOUNTED FLUORESCENT LIGHTING FIXTUREPENDANT MOUNTED FLUORESCENT EMERGENCY LIGHTING FIXTUREWALL MOUNTED FLUORESCENT LIGHTING FIXTURESURFACE MOUNTED DOWNLIGHT FIXTUREEXTERIOR BUILDING MOUNTED LIGHTING FIXTURESYMBOLDESCRIPTIONSYMBOLDESCRIPTIONELECTRICAL SYMBOL LISTaGFIWPIGHSFEOLDFAAFACPSELF CONTAINED EMERGENCY LIGHTING FIXTURE WITH REMOTE CAPABILITYREMOTE DUAL HEAD EMERGENCY LIGHTING FIXTUREWALL MOUNTED EXIT SIGNFIRE ALARM CONTROL PANELFIRE ALARM REMOTE ANNUNCIATOR PANELEND OF THE LINE DEVICEWALL MOUNTED COMBINATION HORN / STROBE LIGHT WITH AN ADA 15/75CANDELA STROBE. MOUNT AT 6'-8" AFFWALL MOUNTED ADA 15/75 CANDELA STROBE UNIT ONLYWALL MOUNTED FIRE ALARM MANUAL PULL STATION. MOUNT AT 48" AFFCEILING MOUNTED SMOKE DETECTORCEILING MOUNTED HEAT DETECTOR - TEMPERATURE RATING AS INDICATEDON DRAWINGSOSTCOS43TELEPHONE OUTLET, TWO GANG BACKBOX WITH 3/4" CONDUIT STUBBEDINTO AN ACCESSIBLE CEILING, PROVIDE NYLON PULL STRING AND BUSHINGCOMBINATION TELEPHONE / COMPUTER OUTLET, TWO GANG BACKBOX WITH3/4" CONDUIT STUBBED INTO ACCESSIBLE CEILING. PROVIDE NYLON PULLSTRING AND BUSHINGSINGLE POLE TOGGLE SWITCHTHREE WAY TOGGLE SWITCHFOUR WAY TOGGLE SWITCHCOMBINATION WALL / OCCUPANCY SENSOR SWITCHTIME CLOCKOCCUPANCY SENSORDCDOOR CONTACTWALL MOUNTED WEATHERPROOF COMBINATION HORN / STROBE LIGHT WITH ANADA 15/75 CANDELA STROBE. MOUNT AT 6'-8" AFFELECTRICAL ABBREVIATIONSFIRE ALARM CONTROL PANELFACPWEATHERPROOFWPWATT, WIREWVOLT AMPEREVAVVOLTSUNIT HEATERUHTYPTYPICALSECONDARY ELECTRICAL SERVICESEPOLYVINYL CHLORIDE CONDUITPVCPHASEPHPEPRIMARY ELECTRICAL SERVICEPOLEPNTSNOT TO SCALENECNATIONAL ELECTRIC CODEMLOMAIN LUGS ONLYKILOWATTKWKVAKILOVOLT AMPEREHZHERTZHPHORSE POWERGROUND FAULT INTERRUPTERGFIGGROUNDFIRE ALARMFAELECELECTRICALEXHAUST FANEFDWGDRAWINGDOWNDNCUHCABINET UNIT HEATERCONDENSING UNIT, COPPERCUCIRCUITCKTC/BCIRCUIT BREAKERCONDUITCAMPS INTERRUPTING CURRENTAICABOVE FINISHED GRADEAFGAFFABOVE FINISHED FLOORALTERNATING CURRENTACAMPEREA/AMPEXISTING TO REMAINREMOVE EXISTINGNEW LOCATION OF EXISTING RELOCATEDNLREEREVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00E-500ELECTRICAL SYMBOLSAND SCHEDULESISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MALIGHTING FIXTURE SCHEDULETYPE MANUFACTURER / MODEL LAMPING VOLTAGEFIXTURE DESCRIPTIONA COOPER LIGHTINGHVL12-4-LD3-2STD-35-UNV-O-ED1C-S-IP6480W LED(3500K)120 V 1'x4' SURFACE MOUNTED LED LUMINAIRE WITH EXTRUDED ALUMINUM HOUSING; 2 LED MODULES AT STANDARDOUTPUT; 4600 LUMEN OUTPUT; SMOOTH OPAL LENS AND SMOOTH END CAPS; SINGLE CIRCUIT ELECTRONIC DRIVER;IP64 RATEDA1 COOPER LIGHTINGHVL12-4-LD3-2STD-35-UNV-O-ED1C-S-PM-IP6480W LED(3500K)120 V SAME AS TYPE 'A' EXCEPT PENDANT MOUNTING WITH BOTTOM OF FIXTURE AT 8'-0" AFFA2 COOPER LIGHTINGHVL12-8-LD3-2STD-35-UNV-O-ED1C-S-PM-TILW-IP64160W LED(3500K)120 V SAME AS TYPE 'A1' EXCEPT 8' LENGTH WITH TANDEM IN-LINE WIRING AND 9200 LUMEN OUTPUTAA1 PHILIPS STONCO SR3SW132HFLB8EOB (1) 32W HPF(3500K)120 V 13" ROUND WALL MOUNTED VANDAL RESISTANT FLUORESCENT LUMINAIRE WITH DIE CAST ALUMINUM HOUSING;SHALLOW DEPTH; LAMPED OPTION; BLACK BASE AND FACE COLOR; CLOSED EYELID STYLE; OPAL LENSB4 PHILIPS LEDALITE 7406LBEQG0411EW 32W LED(3500K)120 V 4' PENDANT MOUNTED LINEAR DIRECT/INDIRECT LED LUMINAIRE WITH PRECISION FORMED STEEL HOUSING; 3400LUMEN OUTPUT; MESO OPTICS LOWER LENS; 80% DOWN UPPER OPTICS KIT; SINGLE CIRCUIT ELECTRONIC DRIVER;STANDARD WHITE FINISH; MOUNT BOTTOM OF FIXTURE AT 8'-0" AFFB8 PHILIPS LEDALITE 7406LBEQG0611EW 64W LED(3500K)120 V SAME AS TYPE 'B4' EXCEPT 8' LENGTH AND 6800 LUMEN OUTPUTD COOPER LIGHTING SLD606-8-35-WH 12W LED(3500K)120 V 6" ROUND APERTURE SURFACE MOUNTED LED DOWNLIGHT WITH DIE CAST ALUMINUM FRAME; 800 LUMEN OUTPUT;ELECTRONIC LED DRIVER; SHOWERTITE RATING; WHITE FINISHEM EXITRONIX LED-RX-GR (2) 1.9 W LEDBY MFR120 V WALL MOUNTED DUAL HEAD LED EMERGENCY LIGHTING FIXTURE WITH GREY POLYCARBONATE HOUSING; IP64 RATED;REMOTE CAPABILITYEM1 EXITRONIX LED-RX-GR (2) 1.9 W LEDBY MFR120 V SAME AS TYPE 'EM' EXCEPT CONNECTED TO DUAL HEAD REMOTE LAMP 'REM'REM EXITRONIX 2CLED-WP (2) 1.2 W LEDBY MFR120 V WALL MOUNTED DUAL HEAD LED REMOTE LAMP WITH WEATHERPROOF OPTIONW PHILIPS DAY-BRITE CSW-48-28-35-U-LAG-ZO 31W LED(3500K)120 V 4' WALL MOUNTED LED LINEAR SURFACE LUMINAIRE WITH DIE-FORMED HEAVY GAUGE STEEL; 2800 LUMEN OUTPUT;ELECTRONIC LED DRIVER; OPAL ACRYLIC LENS.X1 EXITRONIX VEX-WP-1-WB-WH-G2 2W LED 120 V WALL MOUNTED UNIVERSAL LED EXIT SIGN WITH WHITE THERMOPLASTIC HOUSING; SINGLE FACED AND CHEVRONS ASINDICATED ON PLANS; SELF TEST DIAGNOSTICS; SUITABLE FOR WET LOCATIONSX2 EVENLITE RZR-EM-R-1-WW-W-1B LED 120 V SAME AS TYPE 'X' EXCEPT CEILING MOUNTED.MOTOR CIRCUIT SCHEDULEEQUIPMENTCircuitNumberPANEL OCPBRANCHCIRCUITLOCALDISC. SWMOTOR STARTER LOADREMARKSIZE TYPE LOCATION HP MCA / W PHASE VOLTB-1, BP-1 23 P2A 20 A 2#12, #12G IN 3/4"C 20A-1P DIV. 23 DIV. 23 DIV. 23 0.14 (BP-1) 12.0 A (B-1) 1 120 V COORDINATE WITH DIV. 23B-2, BP-2 24 P2A 20 A 2#12, #12G IN 3/4"C 20A-1P DIV. 23 DIV. 23 DIV. 23 0.14 (BP-1) 12.0 A (B-2) 1 120 V COORDINATE WITH DIV. 23CU-1 50,52,54 P2A 50 A 3#8, #10G IN 3/4"C 60A-3P DIV. 23 DIV. 23 DIV. 23 - 45.0 A 3 208 V COORDINATE WITH DIV. 23EF-2 20 P2A 45 A 2#8, #10G IN 3/4"C 60A-1P DIV. 23 DIV. 23DIV. 23 - 30.0 W 1 120 V COORDINATE WITH DIV. 23EF-3 22 P2A 45 A 2#8, #10G IN 3/4"C 60A-1P DIV. 23 DIV. 23DIV. 23 - 30.0 W 1 120 V COORDINATE WITH DIV. 23EF-4 29 P2A 20 A 2#12, #12G IN 3/4"C 20A-1P DIV. 23 DIV. 23 DIV. 23 3/4 - 1 120 V COORDINATE WITH DIV. 23ERV-1, HWP-1, HWP-2 33,35 P2A 20 A 2#12, #12G IN 3/4"C 20A-2P DIV. 23 DIV. 23 DIV. 23 1/4 EA. (HWP) 1.7 A (ERV-1) 1 208 V COORDINATE WITH DIV. 23MAF-1 44,46,48 P2A 20 A 3#12, #12G IN 3/4"C 20A-3P DIV. 23 DIV. 23 DIV. 23 1.5 - 3 208 V COORDINATE WITH DIV. 23PUMP-3 43 P2A 20 A 2#12, #12G IN 3/4"C 20A-1P DIV. 23 DIV. 23 DIV. 23 - 9.8 A 1 120 V COORDINATE WITH DIV. 23PUMP-4.1 25,27 P2A 20 A 2#12, #12G IN 3/4"C 20A-2P DIV. 23 DIV. 23 DIV. 23 - 8.7 A 1 208 V COORDINATE WITH DIV. 23PUMP-4.2 39,41 P2A 20 A 2#12, #12G IN 3/4"C 20A-2P DIV. 23 DIV. 23 DIV. 23 - 8.7 A 1 208 V COORDINATE WITH DIV. 23PUMP-4.3 40,42 P2A 20 A 2#12, #12G IN 3/4"C 20A-2P DIV. 23 DIV. 23 DIV. 23 - 8.7 A 1 208 V COORDINATE WITH DIV. 23PUMP-4.4 45,47 P2A 20 A 2#12, #12G IN 3/4"C 20A-2P DIV. 23 DIV. 23 DIV. 23 - 8.7 A 1 208 V COORDINATE WITH DIV. 23PUMP-16 18 P2A 20 A 2#12, #12G IN 3/4"C 20A-1P DIV. 23 DIV. 23 DIV. 23 - 9.8 A 1 120 V COORDINATE WITH DIV. 23PUMP-23 31 P2A 20 A 2#12, #12G IN 3/4"C 20A-1P DIV. 23 DIV. 23 DIV. 23 - 9.8 A 1 120 V COORDINATE WITH DIV. 23SP-1 49,51,53 P2A 20 A 3#12, #12G IN 3/4"C 20A-3P DIV. 23DIV. 23 DIV. 23 2 - 3 208 V COORDINATE WITH DIV. 23VRV-1-1, VRV-1-2,VRV-1-334,36 P2A 20 A 2#12, #12G IN 3/4"C 20A-2P DIV. 23 DIV. 23DIV. 23 - 1.56 A, 3.5 A,0.44 A1 208 V COORDINATE WITH DIV. 23VRV-2-1, VRV-2-2,VRV-2-328,30 P2A 20 A 2#12, #12G IN 3/4"C 20A-2P DIV. 23 DIV. 23DIV. 23 - 0.63 A, 0.38 A,0.63 A1 208 V COORDINATE WITH DIV. 23Total Amps:Total KW:Total Amps:179.5 A 169.3 A 158.8 ATotal Load:21371 VA 20149 VA 19059 VA83 Space-- --0 VA 0 VA -- -- Space8481 Space-- -- 0 VA 0 VA -- -- Space8279 Space-- -- 0 VA 0 VA-- -- Space8077 Spare20 A 10 VA 0 VA 1 20 A Spare7875 Spare20 A 1 0 VA 0 VA 1 20 A Spare7673 Spare20 A 1 0 VA 0 VA1 20 A Spare7471 Spare20 A 10 VA 0 VA 1 20 A Spare7269 Spare20 A 1 0 VA 0 VA 1 20 A Spare7067 Spare20 A 1 0 VA 0 VA1 20 A Spare6865 Spare20 A 10 VA 0 VA 1 20 A Spare6663 Spare20 A 1 0 VA 0 VA 1 20 A Spare6461 Spare20 A 1 0 VA 0 VA1 20 A Spare6259 Spare20 A 10 VA 0 VA 1 20 A Spare6057 Spare20 A 1 0 VA 0 VA 1 20 A Spare5855 Spare20 A 1 0 VA 0 VA1 20 A Spare5653 ---- --936 VA 4320... -- -- --5451 ---- -- 936 VA 4320... -- -- --5249 SP-120 A 3 936 VA 4320...3 50 A CU-15047 ---- --905 VA 828 VA -- -- --4845 PUMP-4.420 A 2 905 VA 828 VA -- -- --4643 PUMP-320 A 1 1176... 828 VA3 20 A MAF-14441 ---- --905 VA 905 VA -- -- --4239 PUMP-4.220 A 2 905 VA 905 VA 2 20 A PUMP-4.34037 RCPT #20220 A 1 720 VA 1176...1 20 A SECURITY PANEL 3835 ---- --203 VA 572 VA -- -- --3633 ERV-1, HWP-1, HWP-2 20 A 2 203 VA 572 VA 2 20 A VRV-1-1, VRV-1-2, VRV-1-3 3431 PUMP-2320 A 1 1176... 720 VA1 20 A RCPT #1003229 EF-420 A 11656... 131 VA -- -- --3027 ---- -- 905 VA 131 VA 2 20 A VRV-2-1, VRV-2-2, VRV-2-3 2825 PUMP-4.120 A 2 905 VA 720 VA1 20 A DESK RCPT #202 2623 B-1, BP-120 A 11544... 1544... 1 20 A B-2, BP-22421 RCPT #201A, #201 20 A 1 1260... 3600... 1 45 A EF-32219 HEAT TRACE20 A 1 1200... 3600...1 45 A EF-22017 LIGHTING 2ND FLOOR 20 A 11032... 1176... 1 20 A PUMP-161815 RCPT #100, AIR PUMP RCPT 20 A 1 900 VA 1176... 1 20 A FACP1613 RCPT #100, UH-2 20 A 1 876 VA 1040...1 20 A RCPT #2031411 LIGHTING 1ST FLOOR 20 A 1698 VA 804 VA 1 20 A RCPT #103, UH-7 129 RCPT #205, UH-6, WH-1 20 A 1 1148... 786 VA 1 20 A RCPT #100A, EF-1 107 RCPT #204, UH-5 20 A 1 624 VA 720 VA1 20 A DESK RCPT #20185 GFI RCPT #20220 A 1360 VA 540 VA 1 20 A GFI RCPT #20163 LIGHTING STAIR# S1 AND #101 20 A 1 274 VA 396 VA 1 20 A RCPT #100, UH-3, UH-4 41 LTG EXTERIOR DOCK AND SHOWER 20 A 1 256 VA 378 VA1 20 A RCPT #101, UH-1, CUH-1 2CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKTNotes:Enclosure:Mounting:SurfaceWires:4MCB Rating:Supply From:Phases:3Mains Type:Location:Volts:120/208 WyeA.I.C. Rating:Branch Panel: P2A EOLSSS SS HFFSSSSFSDCDCDCDCDCSTREET SIDEDISCONNECTMAINFOR SIZEONE LINE DIAGRAMCONDUCTORS SEESERVICE ENTRANCESEE ONE LINE DIAGRAMMAIN OVERCURRENT DEVICE250.66WITH NEC ARTICLESIZED IN ACCORDANCEMAIN BONDING JUMPERSERVICE PIPECOPPER WATER(TYP.)CLAMPGROUNDJUMPERBONDINGMETERWATERWELD (TYP)EXOTHERMICBUSEQUIPMENT GROUNDNEUTRAL BUS22 FT.ENTRANCE POINT OF PIPEBOND WITHIN (5) FT. OFSWITCHGROUND ROD (TYPICAL OF 3)10' X 3/4" TINNED COPPER22 FT.AUGER HOLE AND FILL WITHTHE EC SHALL PROVIDE AN 8"GROUND ENHANCING BACKFILL-TERRAFILL #TF-50 50 LB BAGSAS REQUIRED.2#12,#12G TO 20A-1PCIRCUIT BREAKER WITHLOCKING HANDLE IN PANELP2A1" MINIMUM SAW CUT IN BITUMINOUS PAVEMENT.PATCH TO MATCH EXISTING SURROUNDINGPAVEMENT CONSTRUCTION AFTER INSTALLATIONOF FEEDER, CONDUIT OR DUCTBANK.IF GRASS IS ENCOUNTERED, REGRADE, REPAIR,AND RESEED TO MATCH SURROUNDINGS.PLASTIC WARNING TAPETO READ "DANGER BURIEDHIGH VOLTAGE FEEDER".COMPACTED BACKFILLIN 6" LIFTSTHERMAL SANDBEDDING 6" MINIMUMCOVER ON ALL SIDES24"BELOWGRADE4" CONDUIT WITH NEWSECONDARY ELECTRICSERVICEEXISTING BITUMINOUSPAVEMENT24"MIN.3" CONDUIT FOR CABLE TV/BROADBAND SERVICE WITHPULLSTRING (FUTURE)3" CONDUIT FORTELEPHONE SERVICEPROVIDE NEW SHEETING AND BRACINGNECESSARY TO SUPPORT THE SIDESDURING EXCAVATION.P2AP2B1ST FLOOR2ND FLOORPANEL P2A208/120V-3PH-4W-200AMIN 25K AIC RATING42 POLE EACH SECTIONINTERIOREXTERIORPROVIDE AND INSTALL NEW 7TERMINAL METER SOCKET, HOTSEQUENCE WITH MANUAL BYPASSAND NEMA 3R ENCLOSURE. FORUSE WITH 208/120V-3PH-4W-200ASERVICE, 25K AIC RATED.NEW SECONDARY SERVICE LATERAL3" PVC SCHED 80 WITH4#4/0 CU TYPE XHHWRUN IN TRENCH WITH WARNING TAPEAND MIN 24" COVER200AMCB#4 AWG CU GECTO DERIVED GROUND SYSTEMPER DETAIL 4/E-800NEW UNDERGROUND SECONDARY SERVICEEXTENDED FROM THE EXISTING RISER POLEON EASTON AVE BY THE UTILITY COMPANY.PRECAST POLYMER CONCRETE GRADE BOX36"X72"X36" WITH H20 LOADING CAPACITY.PROVIDE QUAZITE #PG3672DA36 SOLIDBOTTOM BASE WITH #PG3672HH0017 COVER.MINIMUM DISTANCE 175'-0" THE EC SHALLPROVIDE TRENCHING & BACKFILL, CONDUIT& CONDUCTORS PER DETAIL 3/E-800MAIN DISCONNECT SWITCH240V-3P-200A-NEMA 3RHEAVY DUTY W/ 200A D.E. FUSES1ST FLOOR2ND FLOORFACPSECURITYWPPROVIDE 15'-0" OF EXCESSCONDUCTOR LENGTH FOR FINALTERMINATION BY THE UTILITYCOMPANY.THE CONTRACTOR IS TO BE FULLY RESPONSIBLE FOR CONTACTING THE LOCALCABLE TELEVISION COMPANY, POWER COMPANY, TELEPHONE COMPANY, GASCOMPANY, WATER AND SEWER COMPANY AND ANY OTHER UTILITY COMPANYWITHIN THE AREA PRIOR TO PROCEEDING WITH ANY EXCAVATION. BY LAW, THECONTRACTOR IS REQUIRED TO CALL BEFORE DOING ANY EXCAVATION, DIGGINGHOLES OR DRIVING POSTS REGARDLESS OF WHETHER IT IS WITHIN THE STREETLINE OR ON PRIVATE PROPERTY. OBTAIN INFORMATION REGARDING THE EXISTENCEAND LOCATION OF ANY UNDERGROUND FACILITIES BY CALLING 1-800-922-4455SECURITYOHPROVIDE WIDE GAP CONTACTSAT EACH OVERHEAD DOOR.SEWAGE EJECTORCONTROL PANEL150A 150A 1ST FLOORM2ND FLOORSUB PANEL LEFT120/240-1PH-3WPANEL P2120/240-1PH-3W150A MCBSUB PANELDOCK AREA120/240-1PH-3W-50A8 POLE QO LOAD CENTERSUB PANEL2ND FLOOR120/240-1PH-3W-70APANEL P1120/240-1PH-3W150A MCB-30 POLEINTERIOREXTERIOREXISTING SERVICEENTRANCE METERSOCKETEXISTING UNDERGROUNDSECONDARY SERVICE LATERALSERVICE DISCONNECTSWITCH #1SERVICE DISCONNECTSWITCH #21. THE GROUNDING ELECTRODE SYSTEM SHALL COMPLY WITHARTICLE 250 OF THE CURRENT N.E.C.2. BOND TO ALL GROUNDING ELECTRODE TYPES PRESENT.NOTE: ALL EQUIPMENT SHALL BE REMOVED PER PHASING SCHEDULERJ31XNOTESSCALE: N.T.S.SCALE: N.T.S.SCALE: N.T.S.SCALE: N.T.S.12"WARNING - UNDERGROUND UTILITIESSCALE: N.T.S.SCALE: N.T.S.MNGPANELPANELOH OH5FIRE ALARM RISER DIAGRAM4SERVICE GROUNDING DETAIL2ELECTRICAL POWER RISER DIAGRAM1ELECTRICAL DEMOLITION RISER DIAGRAM3TYPICAL TRENCH DETAIL6SECURITY SYSTEM RISER DIAGRAMREVISIONS54321ABC510 Chapman St, Suite 201Canton, MA 02021Tel. (860) 632-1682Fax. (860) 632-1768CES #2014385.00E-800ELECTRICAL DETAILSISSUED FOR BID19 AUGUST 2015Brant Point PropagationFacility2A EASTON STREET NANTUCKET, MA